  For your safety the information in

this manual must be followed to minimize the risk
of fire or explosion or to prevent property damage,
personal injury or loss of life.

- Do not store or use gasoline or other flammable

vapors and liquid in the vicinity of this or any other
appliance.

- WHAT TO DO IF YOU SMELL GAS

·

Do not try to light any appliance.

·

Do not touch any electrical switch; do not use
any phone in your building.

·

Clear the room, building or area of all
occupants.

·

Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier's
instructions.

·

If you cannot reach your gas supplier, call the
fire department.

Installations must be performed by a qualified or
licensed contractor, plumber, or gasfitter qualified
or licensed by the state, province, or region where
this appliance is being installed.

Contents

SUBJECT

PAGE

Pre-Installation Requirements

2

Electrical Requirements

2

Exhaust System Requirements

2-3

Gas Supply Requirements

3

Location of Your Dryer

4

Mobile Home Installation

5

Rough-In Dimensions

5-6

Unpacking

6

Reversing Door Swing

6

Electrical Installation

7

Grounding Requirements

7

Electrical Connections—3-wire

8

Electrical Connections—4-wire

8

Installation

9

Replacement Parts

9

Printed in U.S.A.

P/N 134296400A (0404)

Installation

Instructions

Gas & Electric

Dryer

Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer
is installed correctly and safely. Leave these instructions near the Dryer after installation for future reference.

NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70 or in Canada, CSA C22.1 Canadian Electrical Code Part 1.

NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Fuel Gas Code ANSI Z223.1 or in Canada, CAN/CGA B149.12.

NOTE: The Dryer is designed under ANSI Z 21.5.1  or ANSI/UL 2158 - CAN/CSA C22.2 (latest editions) for HOME USE only.
This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.

Summary of Contents for P/N 134296400A (0404)

Page 1: ...of Your Dryer 4 Mobile Home Installation 5 Rough In Dimensions 5 6 Unpacking 6 Reversing Door Swing 6 Electrical Installation 7 Grounding Requirements 7 Electrical Connections 3 wire 8 Electrical Connections 4 wire 8 Installation 9 Replacement Parts 9 Printed in U S A P N 134296400A 0404 Installation Instructions Gas Electric Dryer Before beginning installation carefully read these instructions Th...

Page 2: ...contact with exhaust system The dryer MUST NOT be exhausted into a chimney a wall a ceiling or any concealed space of a building which can accumulate lint resulting in a fire hazard Exceeding the length of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts can cause an accumulation of lint in the exhaust system Plugging the system could create a fire hazard as well as increase dryi...

Page 3: ...temperature to air fluff cool down and start the dryer 3 Read the measurement on the manometer 4 The system back pressure MUST NOT be higher than 0 75 inches of water column If the system back pressure is less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 0 75 inches of water column the system is too restrictive and the installation is unacceptab...

Page 4: ... centimeters 3 inches 7 6 cm from bottom and top of door THIS DRYER MUST BE EXHAUSTED OUTDOORS 5 The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm UNDER COUNTER INST UNDER COUNTER INST UNDER COUNTER INST UNDER COUNTER INST UNDER COUNTER INSTALLA ALLA ALLA ALLA A...

Page 5: ...OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL VENT KNOCKOUT VENT KNOCKOUT VENT KNOCKOUT VENT KNOCKOUT VENT KNOCKOUT 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 9 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm MOBILE HOME INSTALLATION 1 Dryer MUST be exhausted outside outdoors not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 inches 10 16 cm in diameter with no obstruction...

Page 6: ...counter model clothes dryers the top panel may be removed for installation 2 Return the dryer to an upright position PACKING FOAM SHIPPING REMOVE 4 SCREWS ONE FROM EACH HINGEFIRST ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS TOP CONSOLE MODELS 68 6 cm 68 6 cm 68 6 cm 68 6 cm 68 6 cm SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW OPTIONAL OP...

Page 7: ...plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances If in doubt call a licensed electrician ALL GAS Dryers This dryer is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong fr...

Page 8: ...UTRAL GROUND WIRE ELECTRICAL CONNECTIONS FOR 3 WIRE SYSTEM Non Canadian ELECTRIC Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp p...

Page 9: ...so see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happen...