Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than 36".
•
Allow 30" minimum clearance between top of cooktop platform
and bottom of unprotected wood or metal overhead cabinet; or 24"
minimum clearance when bottom of wood or metal overhead cabinet
is protected by not less than 1/8" flame-retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" stainless steel,
0.024" aluminum or 0.020" copper.
•
Allow 9" minimum required clearance from left edge and right edge
of cooktop to nearest combustible wall on each side.
Ductwork Preparation
•
For ventilation unit ductwork preparation and planning
information, refer to 36" Electric Cooktop (RC36DE60P) Ductwork
Preparation page.
•
Down discharge can also be adapted for alternate ductwork
installation providing left or right exhaust, by ordering Alternate
Duct Transition Kit (PN # 5304488297).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
Granite Countertop Installation Kit – (PN # 903061-9010).
•
Alternate Duct Transition Kit – (PN # 5304488297).
Built-In Cooktop Specifications
•
Shipping Weight (approx.) – 80 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
•
Connected Load (kW Rating) @ 240 / 208 Volts = 40.8 / 35.7 kW
•
Amps @ 240 / 208 Volts = 50 Amps
•
Recommended Circuit Breaker – 50 Amps
•
Always consult local and national electric codes.
•
For detailed electrical supply location, refer to 36" Electric Cooktop
(RC36DE60P) Ductwork Preparation page.
•
Locate cooktop between wall studs or floor joists so that ductwork
may be installed properly.
•
Installing cooktop into pre-existing base cabinets may require
modifications. Cabinets with drawers require drawers be removed
and drawer fronts attached to cabinet face. Verify internal length
and width of cabinet base because sides or back wall may need cut
out and corner braces removed to accommodate unit.
•
Countertop opening MUST be cut based on dimensions shown, cut
squarely with sides parallel to each other and with front and rear
perpendicular to cabinet sides.
•
Pre-formed countertops with raised lip and radius at base of
backsplash may not allow enough flat area for proper installation.
Minimum 1" distance required from rear and front edge of cooktop
cutout.
•
Overhead cabinetry should not exceed a 13" maximum depth.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
RC36DE60P 07/13
© 2013 Electrolux Home Products, Inc.
Built-In Downdraft Cooktop
RC36DE60PB
36" Electric
36" Electric Cooktop/Downdraft Vent (RC36DE60P)
Non Branded
13"
max.
cabinet
depth
9" min. to nearest
combustible wall
(each side of unit)
30" min. for
unprotected
cabinet bottom
24" min.
for protected
cabinet bottom
36"
18"
min.
1" minimum flat distance
from cutout edge
1" minimum flat distance
from cutout edge
21
1
/
8
" min.
21
1
/
4
" max.
34
1
/
2
" min.
34
5
/
8
" max.
34
7
/
32
"
20
27
/
32
"
3
9
/
32
"
36
3
/
4
"
22
1
/
16
"
Ventilation
unit not shown
beneath cooktop.
24"
For ventilation unit ductwork preparation and
installation planning information, refer to 36"
Electric Cooktop Ductwork Preparation page.
36" Electric Cooktop
with Ventilation Unit
Right Side View
Rear Discharge
Right Side View
Down Discharge
21
11
/
16
"
18
19
/
32
"
23
3
/
8
"