FEM5700/ FEM5700D/ FEM5700M/ FEM5700DM

Electromagnetic Lock

Electro-Magnetic Lock Description:

Power setting and Input 

The FEM5700 is an unmonitored single magnetic lock and FEM5700D is an unmonitored double magnetic 

lock with dual 12 or 24 volt settings. There are no Lock or Door status sensors on these units. For wiring 

instruction refer to figure 2.
The  FEM5700M  is  a  monitored  single  magnetic  lock  and  the  FEM5700DM  is  a  monitored  double 

magnetic lock with 12 or 24 volt settings. Each magnetic lock has a built-in Hall crystal for remote 

monitoring of Lock status (open or closed) through relay contacts rated at 24 VDC, 2.0 A max on 

visible  high  luminosity  backlight  indicator  position  on  the  aluminum  housing  and  a  Door  Status 

Sensors  (DSS)  for  remote  monitoring  of  Door  status  through  reed  switch  contact.  For  wiring 

instruction refer to Figure 1.

The (+) lead of the power source is connected to Pins 1 (VDC +) of the terminal block and the (-) lead 

is connected to Pin 2 (-). The operating switch or controlling contacts must be installed between the 

power source and the magnetic lock to reduce operating time of the magnetic lock to a minimum. The 

electromagnetic lock requires a filtered and regulated DC Power Source for optimal performance.

Remove the wiring cavity cover plate and check the position of the two shunts located on the PCB. A 

single shunt across pins 2 and 3 will set the operating voltage to 24 volts. A shunt between pins 1 to 

2 and a shunt between pins 3 to 4 sets the operating voltage to 12 volts.

These voltage shunts must be set correctly before 12 VDC or 24 VDC power is supplied to the 

Electromagnetic Lock to prevent damage to the unit.

 

 LIGHT PANEL

R

 B G

12 

24 

12

 B 

HR

Light Panel:

 

BLACK

RED

GREEN

RED

BLACK

GREEN

Hall IC Wiring:

R

 B 

G

  

  

  

  

4

  

 3 

 

DSS Wiring:       BLACK

  

-

 

COM

Rated: 30 VDC  

 

RED

      

- NC

0.2 A max.         

  

GREEN - NO

    

                 

12 VDC

24 VDC

1 2 3 4

1 2 3 4

FEM5700M/ FEM5700DM PCB

GROUND

VOLTAGE

+

-

NO

C

NC RELAY NC

RELAY NO
RELAY C

   NO  NC

-   

VDC

C   

   NO  NC

-   

VDC

C   

FEM5700/ FEM5700D PCB

1

2

3

4

GROUND

VOLTAGE

+

-

R
G

B
W

Figure 2

12 VDC

24 VDC

1 2 3 4

1 2 3 4

Figure 1

Power Input

FEM5700/FEM5700M

FEM5700D/FEM5700DM

0.53 A
0.26 A

2 × 0.53 A
2 × 0.26 A

12 VDC
24 VDC

Backlight Indicator OFF

Relay De-energized,

No Power on Magnetic Lock

Relay De-energized,
Relay Energized,

Power on Magnetic Lock and Door is Open.
Power on Magnetic Lock and Door Locked.

Backlight Indicator RED
Backlight Indicator GREEN