FW-1000SA

INSTRUCTION

MANUAL

Alkaline ionizer

Thank you for purchasing our products.

The instruction manual says important matter for use.

Read carefully before use and use this product correctly.

keep this manual at a safe where you can consult it 

whenever necessary.

FW-107T

Summary of Contents for TREVI FW-107T

Page 1: ...ne ionizer Thank you for purchasing our products The instruction manual says important matter for use Read carefully before use and use this product correctly keep this manual at a safe where you can consult it whenever necessary FW 107T ...

Page 2: ......

Page 3: ...ct body 16 How to attach the delivery pipe 19 How to attach the drain hose 19 How to attach the water supply hose 20 How to use alkaline ionized water acid water purified water 21 Check with ORP 23 Precaution for use 23 Measure the pH value of ionized water 24 Refill glycerophosphoric acid calcium 25 Cleaning inside the product 26 Maintenance 27 Exchange of cartridge 28 Q A 31 Specification 34 3 ...

Page 4: ...ou can consult it whenever necessary after reading Improper use may result in injury or damage to property property refers to houses household belongings domestic animals and pets Improper use may result in serious injury or death or damage This notes are the purpose of preventing you or those who are around from harm or damage by using this product correctly The notes are classified as follow Rea...

Page 5: ...may occur Do not use this product with incorrect voltage Fire or electrification may occur Do not damage the power cord and power plug Do not do followings Hold with staple Damage Process Bend Twist Pull close to heating equipment Put heavy objects bundle Tucking it may cause electric shock fire Grab the power plug and unplug it Ask the dealer for repair of power cord or power plug Do not use when...

Page 6: ...th closed container and use within 2 days General bacteria are easy to increase as fungicide in ionized water and purified water is removed Drinking the stored water for a long time may cause disconditioning Flow the accumulated water inside the product in the beginning of use Flow the water for 1 minute a few cup ot water and use the product in every use In case of non use more than 2 days flow t...

Page 7: ...e accessory of pH measurement solution and examine the pH after installation and no use for a long time Use the product after the water of pH9 5 is not over pH10 by the examination Keep examining the water more than once a month Pull out the power plug by holding the actual power plug and not the cord This may cause electrification short circuits or fire Unplug the power cord when not using for a ...

Page 8: ...e touch Multi branch faucet Protect the product by the notification of safty valve in the area that is high water pressure of tap water Protect the product by hot water shut off function if the hot water is flowed by accident Accidental ingestion prevention function Alkaline ionized water for drinking is created preferentially and prevent accidental ingestion of acid water The alarm announce when ...

Page 9: ...cription indicate the page that the explanation is written Front cover Water purification cartridge Delivery pipe Spout Adjuster Operation panel Calcium cap Calcium case Body Accessory Multi branch faucet Delivery pipe Drain hose Fixing sucker Cartridge exchange seal Calcium glycerophosphate Accessory for mounting multi branch faucet spoon for calcium glycerophosphate Name of each part Introductio...

Page 10: ...on Select button for the type of cartridge Select lamp for the type of cartridge Select lamp for the life of cartridge Select button for the life of cartridge Reset button for replacement of cartridge Refresh button Temperature rise warning lamp Name of each part Introduction Digital display part pH value of generating ionized water and ORP value is displayed All the displayed value is indication ...

Page 11: ...ing completion drawing Delivery pipe water faucet Not in the accessories Multi branch faucet Water supply hose Power plug Power cord Drain hose Fixing sucker Drain hose Water from here cannot drink Introduction ...

Page 12: ...ater come out when the water pressure become too high inside the product Hot water spout hot water come out from the spout when switching lever is set on ionized water purified water and hot water over 50 flow Metal net Remove the accumulated garbage with brush when the amount of tap water ionized water purified water is less or after using for a long time more than 6 months How to use Ionized wat...

Page 13: ... too high when water pressure of tap water is high or the water pressure inside the product become about 500kPa 5kgf cm2 caused by clogging of dirt in the cartridge Reduce the water pressure by squeezing the cock of tap water when water come out from safty valve Works Multi branch faucet is not attachable to following water faucet Diameter of external thread more than 23mm Diameter of faucet more ...

Page 14: ...t is made of plastic Recommend to change the faucet Notice Packing How to install CAUTION Turn the accessory of external and internal thread with coin and attach the Branch faucet tightening cap on the faucet Let branch faucet tightening cap in Tighten the branch faucet tightening cap with fitting the branch faucet horizontally from underneath External thread When use white external thread and the...

Page 15: ...ll Let the 16mm or 19mm of mounting accessory into the pipe Let the branch tightening cap into the pipe The board of adaptor assy for branch faucet Remove the screw and let the metal fitting into the branch faucet Loose the screw and place the branch faucet onto the faucet horizontally with pressing and tighten it Do not tighten too much It may make a hole on the faucet Tighten the branch faucet a...

Page 16: ...r Refrigerator Where it is exposed to direct sunlight Where the oil is attached Where it is exposed to wind and rain or outdoors Bathroom or where it is exposed to water steam Where there is a possibility of freezing Do not extend the water outlet with commercial hose It may cause failure Do not connect other equipment to water supply hose or drain hose It may cause water leak or failure Do not op...

Page 17: ...e installation in case of using the product over the wall It may cause an accident by dropping the machine Screw the wooden screws in either virtical one or horizontal one How to install CAUTION Cut Screw hole position chart for the wall page on 18 along with dotted line put the tape and screw the wodden screw in the accessory from the top of the position chart Leave 8 9mm Hook the mounting hole i...

Page 18: ...utoff line and use it for the reference of screw hole position Make sure to save it after using 160mm 160 mm Make a space over 11cm on the top so that the calcium case can be removed when install the product over the wall 11cm and over Calcium case Cu t o f f lin e ...

Page 19: ...ure the drain hose with drain hose Fixing sucker Delivery pipe Screw the delivery pipe to the root Attach this part The spigot part How to install Attention Attention The difference in height of tip of delivery hose and drain hose should be 15cm to less than 40cm Drain hose should be lower than the bottom of the product If the drain hose is too long cut and use it Make sure the drain hose does not...

Page 20: ...ranch faucet 2 1 Hose tightening cap Water supply hose Water supply hose Hose tightening cap Attach this part Make enoough space that the faucet can move side to side CAUTION Do not bend or twist the water supply hose It may cause water leak Do not connect with the faucet of hot water only It may cause malfunction Do not use hot water when connected with mixing faucet It may cause malfunction How ...

Page 21: ...ater until the water become clear Plug into erectrical out let and push the power button Power lamp is on Switch the lever to Tap water and use it after the water become clear as the water after the water supply work may become cloudy It may cause the clogged filter in the cartridge Do not unplug the power plug do not use the product remining the power off If the product is used without energizati...

Page 22: ...ain the capability of the product and it sounds a clicky sound after cleaning When the cock is closed the switch lever is switched to Tap water after using alkaline ionized water The sound means that electric component is operating this is not a malfunction Use this product after the digital display change from blinks to lighting Digital display changes to lighting after water pass for 3 seconds w...

Page 23: ...a cup of water per 6 seconds Check with ORP Display the ORP indication of creating water when push the ORP button while alkaline ionized water acid water is running ORP is displayed the value under the particular condion It is not the measured value of actual created water Actual value may be different depends of water quality ORP display button ORP display lamp Precaution for use When use this pr...

Page 24: ...H comparison paper in the dark place because these change the color by the sunlight In case of using the tap water which is based on well water in the area it may contain much carbonic acid The pH value and pH testing liquid may show the difference because of the effect of this carbonic acid Refer to page 32 that says about reason and treatment of Alkaline ionized water doesn t show blue or mazari...

Page 25: ...s to be used in case pH value doesn t rise or to promote electrolyzation It is not for the purpose of ingestion of calcium Do not use except the specified calcium Make sure to conform to the amounts of calcium Take out the remaning calcium when not use for a long time more than about a wek Clean the calcium case and cap once a week It may get moldy if the calcium case get dirty How to melt the cal...

Page 26: ...r and take the front cover out Turn the switch lever to Ionized water Purified water and open the water cock Do not stop running the tapwater during cleaning Keep pushing the refresh button on the setting panel for more than 2 seconds Refresh lamp blinks and alarm Refresh button 1 2 3 4 Front cover Switch lever Keep running water and confirm the refresh lamp lights off and stop alarming after 2 mi...

Page 27: ... may have clogging and water quantity become less Take apart the multi branch faucet and remove the garbage in the metal net or shower cap with toothbrush when Purified water Ionized water Shower of tap water Straight of tap water become less amount or after using more than 6 months Pay attention not to lose the parts when it is taken apart Refer to the assembling drawing not to make a mistake Do ...

Page 28: ...e of cartridge even if it is before the lighting up or blinking of cartridge exchange lamp Cartridge exchange lamp approx 40L approx 90L approx 150L approx 200L FW 4000F FW 9100N FW 8000T FW 9000C FW 8000T FW 8000T FW 4000F FW 9000C FW 9100N FW 4000F FW 9100N FW 9000C removable trihalomethane removable trihalomethane removable trihalomethane removable chlorine removable chlorine removable chlorine...

Page 29: ... cartridge is different by turbidity of law water concentration of residual chlorine or total trihalomethane Water quantity may decrease regardless of the period of use when turbid water or red rust come into the product by water service works etc Exchange the cartridge in this case as well The water quantity of ionized water purified water may decrease in following case Water temperature is low I...

Page 30: ...mp of cartridge type 1 2 3 Keep running water a few minutes until the water turn to clear after confirming no water leak is found when it pass the product The black water is the powder of activated carbon Bubbles may be mixed in ionized water purified water or water quantity may decrease after changing the cartridge The air inside the cartridge is not deflated it become normal condition after runn...

Page 31: ...r a while Check if the cartridge exchange reset button is pushed Keep pushing the cartridge exchange reset button for more than 2 seconds when it is exchanged Cartridge exchange lamp remain lighting on Cartridge exchange lamp lights on earlier Check if the life setting of cartridge isn t set as trihalomethane If trihalomethane is set cartridge exchange lamp lights on earlier Residual chlorine is s...

Page 32: ...pH9 0 in a cup 2 add a few drops of pH testing liquid into the dedicated cup 3 pour the alkaline ionized water of 1 to the scale mark of the dedicated cup The color turns to green or yellow from blue or navy at the moment of adding the alkaline ionized water if carbonic acid is contained 24 27 28 30 26 28 30 21 23 21 23 25 26 ー Check if the multi branch faucet isn t clogged Remove the garbage from...

Page 33: ...er rice can be cooked because starchiness in rice is soften by alkaline Reduce pH value or use purified water Water come out from the bottom of the product There is a hole at the bottom to drain for the case water comeinto the product The spilled water come out when exchange the cartridge Wipe the spilled water and use it It has clicky sound from the product It is the operating sound of electronic...

Page 34: ...57mm x H341mm Water discharge branch faucet Switch lever Water purification cartridge FW 8000T body built in 2 Approx 2 1L min Water amount of spout Approx 0 7L min Water amount of drain outlet 2 Water pressure100kPa 1kgf cm To reach 0 4mg L of filtered water concentration 2mg L of raw water residual chlorine concentration Exchange system One touch exchange system Dissolved organic material Residu...