BEFORE CLEANING
Remove documents from the stacker.
Pull up the lever on the right front of
the upper transport and raise it.
Pad Assy
Guide Plate
Pull the ADF release lever towards you
and lift up the ADF upper sheet guide.
Press down on the upper part of the
guide plate with your fingers at the
two positions shown, rotate the plate
towards you and remove it.
Wipe the translucent rubber part of
the pad ASSY using cleaning paper
moistened with cleaner F1.
Cleaning the Pad -
Recommended Cleaning Cycle Every 300,000 Sheets
Parts
Part Number
Pad
CA04315-G730
Pick Roller
CA03296-F711
Brake Roller
CA04315-F705
Cleaning Kit
SC-CLE-KIT2
Note: Please ensure Cleaner F2 is
NOT
used on Rubber Rollers.
Cleaning Instructions for
fi-4860C2 Scanner
ADF Upper Sheet Guide
ADF
Release
Lever
Pad (Cleaning Area)
Pad
Assy
Guide
Plate
Pick Roller Unit
Ring
Shaft
Ring
Ring
Pick Roller Unit
Separation
Roller
While pulling the ADF lever towards you,
lift up the ADF upper sheet guide.
Slide the Pick Roller unit to the left to
disengage the clutch ring from the shaft.
Wipe both Pick Rollers (2 positions)
and the Separation Roller using
cleaning paper moistened with F1
cleaner.
Cleaning the Pick Roller -
Recommended Cleaning Cycle Every 300,000 Sheets
1
2
3
1
2
3
For further cleaning
instructions please
refer to the
fi-4860C2 Image
Scanner Operators
Guide
which can be found on
our Website:
www.fel.fujitsu.com/scanner