background image

BEFORE CLEANING

Remove documents from the stacker.
Pull up the lever on the right front of
the upper transport and raise it.

Pad Assy

Guide Plate

Pull the ADF release lever towards you
and lift up the ADF upper sheet guide.

Press down on the upper part of the
guide plate with your fingers at the
two positions shown, rotate the plate
towards you and remove it.

Wipe the translucent rubber part of
the pad ASSY using cleaning paper
moistened with cleaner F1.

Cleaning the Pad - 

Recommended Cleaning Cycle Every 300,000 Sheets

Parts

Part Number

Pad

CA04315-G730

Pick Roller

CA03296-F711

Brake Roller

CA04315-F705

Cleaning Kit

SC-CLE-KIT2

Note: Please ensure Cleaner F2 is 

NOT

used on Rubber Rollers.

Cleaning Instructions for

fi-4860C2 Scanner

ADF Upper Sheet Guide

ADF

Release

Lever

Pad (Cleaning Area)

Pad

Assy

Guide

Plate

Pick Roller Unit

Ring

Shaft

Ring

Ring

Pick Roller Unit

Separation

Roller

While pulling the ADF lever towards you,
lift up the ADF upper sheet guide.

Slide the Pick Roller unit to the left to
disengage the clutch ring from the shaft.

Wipe both Pick Rollers (2 positions)
and the Separation Roller using
cleaning paper moistened with F1
cleaner.

Cleaning the Pick Roller - 

Recommended Cleaning Cycle Every 300,000 Sheets

1

2

3

1

2

3

For further cleaning

instructions please

refer to the

fi-4860C2 Image

Scanner Operators

Guide

which can be found on

our Website:

www.fel.fujitsu.com/scanner