background image

Operating Manual - English

PRIMERGY BX900 S2 

Blade Server  

System Unit Operating Manual

Edition December 2012

Summary of Contents for Primergy BX900 S2

Page 1: ...Operating Manual English PRIMERGY BX900 S2 Blade Server System Unit Operating Manual Edition December 2012 ...

Page 2: ...ntation mbH 2012 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 13563 001 fm Copyright 2012 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes ...

Page 3: ... components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The customer ...

Page 4: ... the power supply caused by lightning To prevent a momentary voltage drop use of an AC uninterruptible power supply is recommended This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produc...

Page 5: ...ty instructions 35 4 2 CE conformity 43 4 3 FCC Class A Compliance Statement 43 4 4 Environmental protection 45 5 Hardware installation 47 5 1 Unpacking the system unit 48 5 2 Installing removing the system unit 49 5 2 1 Installation in PRIMECENTER DataCenter rack 51 5 2 2 Installing removing the system unit 57 5 3 Connecting devices to the system unit 60 5 3 1 Cable routing 61 5 4 Connecting the ...

Page 6: ...GbE Switch IBP 36 12 SB11A 79 6 1 3 3 Connection Blade GbE Switch IBP 36 8 2 SB11 81 6 1 3 4 Connection Blade 10 GbE Switch IBP 18 8 83 6 1 3 5 Connection Blade Ethernet Pass Thru 10Gb 18 18 85 6 1 3 6 Connection Blade 8Gb FC Switch 18 8 86 6 1 3 7 Connection Blade 8Gb FC Pass Thru 18 18 87 6 1 3 8 Connection Blade DCB SW 10Gb 18 6 6 88 6 1 3 9 Connection Blade FEX B22F 10Gb Cisco 90 6 1 3 10 Conn...

Page 7: ... R Security functions in the BIOS Setup of the server blades and on the system boards protect the data on the blade server from manipulation Additional security is provided by the lockable rack door The BX900 S2 system unit takes up 10 height units U in the rack 1 1 Concept and target groups for this manual This operating manual describes how to install set up and operate your system unit This ope...

Page 8: ...lade Server for the Japanese market only included as a printed copy Quick Start Software Quick Installation Guide DVD booklet only included with the ServerView Suite as a printed copy Safety Notes and Regulations manual 安全上のご注意 for the Japanese market Warranty manual 保証書 for the Japanese market Returning used devices manual and Service Desk leaflet サポー ト サービス for the Japanese market PRIMERGY BX900...

Page 9: ...age showing the online documentation available on the Internet can be found using the URL for EMEA market http manuals ts fujitsu com The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option For the Japanese market Please refer to the following URL for the latest product manuals http jp fujitsu com platform server primergy manual Before using the prod...

Page 10: ...are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and terms that are being emphasized Ê describes activities that must be performed in the order shown V CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates a...

Page 11: ... the back of the PRIMERGY server provide you with information if a CSS event arises The ServerView Local Service Display for Blade enables you to identify the type of component affected by the error directly on the server In addition CSS errors are displayed in the management blade web interface and in the ServerView Operations Manager the server management software from Fujitsu In the event of er...

Page 12: ..._local work WALTER OBJ_DOKU 13566 001 fm http jp fujitsu com platform server primergy system for the Japanese market Server blades The PRIMERGY BX900 S2 system unit has 18 half height or 9 full height bays on the front for server or storage blades Figure 1 Numbering of the server blade slots 1 2 3 4 17 5 6 7 8 9 10 11 12 18 13 14 15 16 ...

Page 13: ...20 S3 server blade Processor type Intel Xeon processor E5 2400 family Processor quantity 1 2 Max per system unit 18 Memory slots 12 Maximum memory capacity 384 GB PRIMERGY BX922 S2 server blade Processor type Intel Xeon 5500 or 5600 series Processor quantity 1 2 Max per system unit 18 Memory slots 12 Maximum memory capacity 192 GB PRIMERGY BX924 S2 server blade Processor type Intel Xeon 5500 or 56...

Page 14: ...oltage and the redundant power supply requirements see the PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual For further information on the server blades see the relevant operating manuals PRIMERGY BX924 S3 server blade Processor type Intel Xeon processor E5 2600 family Processor quantity 1 2 Max per system unit 18 Memory slots 24 Maximum memory capacity 768 GB PRIMERGY BX960 S1 server ...

Page 15: ... to server blade in the adjacent slot to the left or to the right PRIMERGY SX940 S1 storage blade Storage media 2 5 inch HDD or SSD modules Disk slots quantity 4 Max per system unit 6 Installable in slots 2 17 7 10 18 15 Connected to server blade in the adjacent slot to the left or to the right PRIMERGY SX960 S1 storage blade Storage media 2 5 inch HDD or SSD modules Disk slots quantity 10 Max per...

Page 16: ...stem unit 3 Installable in slots 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Connected to server blades with SAS mezzanine card via SAS connection blade PRIMERGY SX980 S2 storage blade Storage media 2 5 inch HDD or SSD modules Disk slots quantity 10 Max per system unit 3 Installable in slots 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Connected to server blades with SAS mezzanine card via SAS connection bla...

Page 17: ...n the back Connection blades provide the installed server blades with connections to the Ethernet LAN as well as to SAN environments and SAS storage environments The connection blade slots of the BX900 S2 system unit are numbered as follows Figure 2 Connection blade slots CB1 CB3 CB5 CB7 CB2 CB4 CB6 CB8 Fabric 1 Fabric 2 Fabric 3 Fabric 4 ...

Page 18: ...nit Server blade Connection blade slots Fabric 1 CB1 1Gb Ethernet or CB2 1Gb Ethernet or 10 Gb Ethernet or 10 Gb Ethernet or Onboard LAN controller DCB SW 10Gb or DCB SW 10Gb or Onboard CNA controller FEX B22F 10Gb Cisco FEX B22F 10Gb Cisco Fabric 2 CB3 1Gb Ethernet or CB4 1Gb Ethernet or Mezzanine card 1 10 Gb Ethernet or 10 Gb Ethernet or DCB SW 10Gb or DCB SW 10Gb or FEX B22F 10Gb Cisco or FEX ...

Page 19: ...ons Installable in all connection blade slots I This connection blade can be used as a layer 2 switch or an Intelligent Blade Panel IBP 1Gb Ethernet connection blades in slots CB3 4 fabric 2 CB5 6 fabric 3 and CB7 8 fabric 4 only support server blades that are fitted with an 1 Gb Ethernet mezzanine card Connection Blade GbE Switch IBP 36 12 SB11A 36 internal 1 Gbit s ports to the server blades 8 e...

Page 20: ...le 1 internal stacking port to the midplane of the BX900 S2 system unit 1 external stacking port through a CX4 connection Installable in all connection blade slots I This connection blade can be used as a layer 2 switch or an Intelligent Blade Panel IBP The stacking ports allow up to 8 SB11 connection blades to be switched together to form a so called stack see the PRIMERGY BX900 S2 System Unit Up...

Page 21: ...fitted with corresponding 10 Gb or 1 Gb Ethernet mezzanine cards or 10 Gb CNA mezzanine cards The 18 internal ports are divided into 9 groups Each port group is associated with two server blade slots on top of each other The ports within a single group must use the same link protocol with either 10 Gbit s or 1 Gbit s link speed Default link speed is 10 Gbit s The management blade web interface all...

Page 22: ...bric 2 and CB5 6 fabric 3 I 10 Gb Ethernet Pass Thru connection blades in slots CB3 4 fabric 2 and CB5 6 fabric 3 only support server blades that are fitted with 1Gb or 10 Gb Ethernet mezzanine cards or 10Gb CNA mezzanine cards The 18 internal ports are divided into 6 groups Each port group is associated with three server blade slots The ports within a single group must use the same link protocol ...

Page 23: ...e in three license variants Brocade 5450 with 14 port license Brocade 5450 with 26 port license Brocade 5450 with 26 port license and performance bundle As the operating system for the 8 Gb FC Switch Connection Blade 18 8 the complete functional scope of Brocade Fabric OS the shared software platform for Brocade Fibre Channel switches is available The FC switch blade is administered via Fabric Wat...

Page 24: ...ports server blades that are fitted with one of the following mezzanine cards 10 Gbit CNA mezzanine card MC CNA102E 10 Gbit CNA mezzanine card MC CNA112E 10 Gbit Ethernet mezzanine card Connection Blade FEX B22F 10Gb Cisco 16 internal 10 Gbit s ports to the server blades 8 external 10 Gbit s Ethernet ports for connection to the parent Cisco Nexus 5000 Series Switch through Cisco branded copper Twi...

Page 25: ...fabric 2 CB5 6 fabric 3 and CB7 8 fabric 4 I Connection Blades Infiniband Switch 40 Gb 18 18 only support server blades that are fitted with an 40 Gb Infiniband mezzanine card PY IB CX2 Mezz Card 40Gb 2 Port Connection Blade Infiniband Switch 56 Gb 18 18 FDR 18 internal 56 Gbit s ports to the server blades 18 external 56 Gbit s Infiniband connections through QSFP modules 1 external debug port thro...

Page 26: ...he ServerView management blade is compliant with IPMI Intelligent Platform Management Interface 2 0 It supports schemes like FRU Field Replaceable Units SEL System Event Log SDR Sensor Data Records and the PDA Prefailure Detection and Analysis technology from Fujitsu It also allows the configuration of a watchdog timer Communication with the server blades The ServerView management blade communicat...

Page 27: ...de S1 User Interface Description Power supply The system unit has six installation bays for hot plug power supply units There are two types of power supply units available standard PSU and High Efficiency PSU hereinafter referred to as HE PSU see Electrical data standard PSU on page 31 and Electrical data HE PSU on page 31 Both types automatically set themselves to a voltage in the range of 100 24...

Page 28: ...ation with ServerView Resource Coordinator Virtual Edition RCVE and the ServerView Resource Orchestrator ROR the PRIMERGY BX900 S2 can completely protect itself against any possible failure at the same time it excels with the fastest automatic recovery and with an allocation of its available resources to services according to requirements Service and support PRIMERGY servers are easy to maintain a...

Page 29: ...erial 1 9 pin 1 x serial RS 232 C Management LAN RJ 45 Management LAN ports for blade server management 2 x 1 Gbit s Ethernet Service LAN RJ45 Dedicated Service LAN port for MMB 1 Gbit s Ethernet Dual Server Blades or Storage Blades 18 x Management Blades 2 x Connection Blades 8 x 2 per 4 fabrics PSU 6 x Operating buttons On off button ID button Status LEDs ID indicator blue Power indicator orange...

Page 30: ...m Bezel 445 mm Body x 778 mm x 438 mmm Height Unit Rack 10 U Weight Up to 204 kg Weight notes Weight may vary depending on actual configuration Rack mounting kit Included Environment class 3K2 Environment class 2K2 EN 60721 IEC 721 Part 3 3 EN 60721 IEC 721 Part 3 2 Temperature Operation 3K2 5 C 35 C Transport 2K2 20 C 60 C Humidity 10 85 non condensing Sound power level LWAd ISO 9296 8 6 B operat...

Page 31: ...EMEA market 1635 VA 100 V EMEA market 2550 VA 230 V Japanese market 1120 VA 100 V Japanese market Heat dissipation 11520 kJ h with 3200 W EMEA market 9000 kJ h with 2500 W Japanese market 5760 kJ h with 1600 W EMEA market 3999 kJ h with1080 W Japanese market Main power fuse 16 A Protection class I Rated voltage range 100 240 V Frequency 50 Hz 60 Hz Max rated current 230 V 13 7 A 100 120 V 16 A 200...

Page 32: ...N 50371 EN 50392 Ergonomics ISO 9241 3 EN 2941 3 EK1 ITB 2003 2007 USA Canada CSA C22 2 No 60950 1 07 2ed UL 60950 1 2ed Taiwan CNS 14336 China GB 4943 Electromagnetic compatibility International CISPR 22 Europe EN 55022 Class A EN 55024 EN 61000 3 2 EN 61000 3 3 ETSI 300386 USA Canada 47CFR part 15 Class A ICES 003 Taiwan CNS 13438 Class A China GB 9245 GB 17625 Japan VCCI Class A JEITA Korea KN ...

Page 33: ... order lists Ê Connect the cables see section Connecting devices to the system unit on page 60 Please also read the section Notes on connecting disconnecting cables on page 65 Ê Connect the system to the mains see section Connecting the system unit to the mains on page 61 Ê Familiarize yourself with the control and display elements on the front and back of the system unit see section Control and d...

Page 34: ...34 Operating Manual BX900S2 Installation steps overview cognitas Gesellschft für Technik Dokumentation mbH 2012 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 13567 001 fm ...

Page 35: ... to install the server including hardware and software Repairs to the device that do not relate to CSS failures shall be performed by service personnel Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability Any failure to observe the guidelines in this manual and any improper repairs could expose the user to risks electric s...

Page 36: ... that the local mains voltage lies within these limits This device must only be connected to properly grounded power outlets or connected to the grounded rack internal power distribution system with tested and approved power cords Ensure that the device is connected to a properly grounded power outlet close to the device Ensure that the power sockets on the device and the properly grounded power o...

Page 37: ...ents and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals If you install other expansions they may damage the system or violate the safety regulations Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet The components marked with a warning notice e g ligh...

Page 38: ...ions in former device position To use a screw of the different kind can cause a breakdown of equipment The installation indicated on this document is sometimes changed to the kind of possible options without notice Batteries Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer D...

Page 39: ...ment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck High humidity and airborne dust levels are to be avoided Electric shocks and or server failures may be caused by liquids such as water or metallic items such as paper clips entering a drive Shocks and vibrations are also to be avoided Do not insert any objects other than the spe...

Page 40: ... CD DVD BD with a soft dry cloth then let it air dry Do not dry the CD DVD BD using devices such as a hair dryer To avoid dust damage and deformation keep the CD DVD BD in its case whenever it is not in use Do not store CDs DVDs BDs at high temperatures Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided I You can prevent damage from the optical disk drive and t...

Page 41: ...ricity To ensure reliable protection you must wear an earthing band on your wrist when working with this type of module and connect it to an unpainted non conducting metal part of the system Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edge...

Page 42: ...arry the system unit mount the handles on the long sides of the unit Only lift or carry the system unit by the handles on the long sides Never lift or carry the system unit by the handles on the front or back Notes on installation into the rack For safety reasons at least 3 people are required to install the system unit in the rack because of its weight and size For the Japanese market please refe...

Page 43: ...distributed over the three phases of a three phase mains connection Other important information During cleaning observe the instructions in section Cleaning the system unit on page 102 Keep this operating manual and the other documentation such as the technical manual documentation DVD close to the device All documentation must be included if the equipment is passed on to a third party 4 2 CE conf...

Page 44: ... be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio ...

Page 45: ...ly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling consumable...

Page 46: ...consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 525 1410 Fax 49 5251 525 32 1410 The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EC on waste el...

Page 47: ...and heat Make sure that the server is acclimatized for the time indicated in this table before putting it into operation In the table Acclimatization time the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously outside transport or storage temperature Temperature difference C Minimum acclimatiz...

Page 48: ...nese market please refer to 安全上のご注意 Only unpack the system unit at the place where you want to set it up Ê Unpack all the individual parts Keep the original packaging of the system unit as you may need it for future transport applies only to EMEA market Ê Check the delivery for any damage during transport Ê Check whether the items delivered match the details on the delivery note The product name a...

Page 49: ...em unit weighs more than 21 kg and is to be installed above the height of 25 U When using a lifter this install removal procedure needs to be carried out by maintenance personnel The rack may tip over if more than one unit is removed at the same time For configurations below 32 kg At least two people are needed to lift the system unit For configurations below 55 kg At least three people are needed...

Page 50: ...refer also to the Rack system structure guide I Online documentation for rack installation can be found on http manuals ts fujitsu com index php id 5406 5605 5606 for the EMEA market http jp fujitsu com platform server primergy manual peri_rack html for the Japanese market To accommodate the ventilation concept and ensure proper ventilation any unused areas in the rack must be sealed using dummy c...

Page 51: ...the current support system For other support systems you will find the appropriate description in the packaging of the rack mounting kit General information regarding server installation in the rack is included in the manual for the appropriate rack Positioning the system unit in the rack The BX900 S2 system unit occupies 10 Height Units HU in the rack The figure 4 and figure 5 show the position o...

Page 52: ...umentation mbH 2012 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 13569 001 fm Figure 4 Position of the system unit in the rack front support uprights Position of M5 screws including plugwashers Position of cage nuts A Carrier rails A A 1 10 15 20 25 30 5 1 10 15 20 25 30 5 ...

Page 53: ... rear support uprights Ê Clarify the position of the system unit in the rack Ê Mark the position of the bottom edge of the system unit on the support uprights Position of centering screws Position of the insert knob A Carrier rails B Holding down clamps A A B B 1 10 15 20 25 30 5 1 10 15 20 25 30 5 ...

Page 54: ...ed on the rear left support upright flush with the bottom edge of the device I The support bracket is not necessary for the symmetrical rack Ê Read the installation guide in the manual for the corresponding rack Ê Mark the position of the bottom edge of the system unit on the support uprights Figure 6 Attaching the support brackets Ê Position the support bracket at the relevant height on the rear ...

Page 55: ...ctly on the support upright Ê Fasten the second holding down clamp at the same height as the first one to the rear right support upright using two centering screws Ê Identify the right and the left rail Figure 7 Attaching the left carrier rail Ê Position the carrier rail in the support bracket insert knob see 1 I For the symmetrical racks The support bracket is not necessary for the symmetrical ra...

Page 56: ... centering screws 2 Ê Position the carrier rail in the front left support upright Ê Fasten the carrier rail to the front support upright 3 using three M5 screws including plugwashers Ê Repeat the operation for the right carrier rail This rail does not require a support bracket Figure 8 Position of the cage nuts Ê Fit the cage nuts for securing the system unit in the corresponding catches on the ri...

Page 57: ... unit by the handles on the long sides Never lift or carry the system unit by the handles on the front or back Ê Make a note of the positions of the individual server blades and storage blades the connection blades power supply units and fan modules in the system unit for reinstallation Ê Remove the server blades storage blades power supply units fan modules connection blades management blades and...

Page 58: ...569 001 fm Figure 9 Placing the system unit on the rack rails I Before inserting the system unit in the rack ensure the stability of the rack Ê Lift the back end of the system unit onto the carrier rails in the rack Ê Remove the back handles both sides on the side of the system 1 Ê Push the system unit into the rack until just before the front pair of side handles 2 2 ...

Page 59: ...ement blades power supply units fan modules and dummy modules in their old bays see page 57 Installation of these components is described in the PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual V CAUTION Incorrect fitting of the system unit may lead to serious errors Removing the system unit V CAUTION Make a note of the positions of the individual server blades storage blades connectio...

Page 60: ...or connection blades For information on the ports of the connection blades see Indicators and connectors of the connection blades on page 78 MMB 1 2 The management blades have the following ports 1 Service LAN port as a point to point connection for system unit administration only no access to server blades and connection blades 2 USB ports for backing up and restoring the MMB configuration and fo...

Page 61: ...em unit to the mains The system unit has six bays for hot swap power supply units In the base configuration it is fitted with three power supply units V CAUTION Read the information on determining how many power supply units are required see the PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual The power supply units automatically adjust to a mains voltage between 100 240 V The system u...

Page 62: ...power distribution unit or an external socket AC source phase redundancy Make sure that the individual power supply units are connected to different AC sources phases This ensures additional AC source phase redundancy for high availability configurations If only one AC source phase fails the power supply units connected to the other AC sources phases remain operational Figure 12 Numbering of the p...

Page 63: ...re sufficient to deliver the required power Power system with 3 AC sources phases available With 6 power supply units you must connect units 1 and 4 to the first AC source phase units 2 and 5 to the second and units 3 and 6 to the third Thus 4 2 redundancy is supported the system continues to run if one source fails provided the remaining 4 power supplies are sufficient to deliver the required pow...

Page 64: ... prevent the C19 connector from being pulled out of the server accidentally The cable tie is included in the accessories pack that is delivered together with the server Figure 13 Using cable ties Ê Route the cable through the loop of the cable tie Ê Pull the cable tie tight to secure the power cable The insulated connector cannot now be disconnected from the server accidentally I You can undo the ...

Page 65: ...g cables Ê Turn off all power and equipment switches Ê Disconnect all power plugs from the properly grounded power outlets Ê Connect all cables to the server and peripherals Ê Plug all data communication cables into the utility sockets Ê Plug all power cords into the properly grounded power outlets Disconnecting cables Ê Turn off all power and equipment switches Ê Disconnect all power plugs from t...

Page 66: ...cal work WALTER OBJ_DOKU 13569 001 fm Information for ensuring electromagnetic compatibility All data and signal cables must have sufficient shielding The use of cable type S FTP Cat5 or better is recommended Use of unshielded or badly shielded cables may lead to increased emission of interference and or reduced fault tolerance of the device ...

Page 67: ...d is used for local diagnostics and administration of the blade server It is also used for the initial configuration of the management blades see Configuring management blades on page 96 Figure 14 ServerView Local Service Panel The most important control and display elements can also be found on the front of the ServerView local service panel This means they are also available when it is folded aw...

Page 68: ... Dokumentation mbH 2012 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 13570 001 fm Figure 15 Locking the ServerView local service panel V CAUTION Press the touch point see arrow of the ServerView local service panel before you push it back into the frame of the system unit ...

Page 69: ...Figure 16 Control and display elements on the front of the ServerView local service panel 1 CSS indicator 5 Power indicator 2 Global Error indicator 6 ID indicator 3 ID button 7 Navigation buttons for the LocalView menu system 4 On Off button 1 2 3 4 5 6 7 ...

Page 70: ...V CAUTION Risk of loss of data I The On Off button does not disconnect the server from the mains voltage To disconnect from the mains completely remove the power plug s ID ID button Lights up blue on the front and on the rear of the system unit when the ID button is pressed The two ID indicators are synchronized Navigation buttons for the LocalView menu system With the buttons and you select a fun...

Page 71: ... S3 s Web interface CSS CSS indicator yellow Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself for reasons of precaution with the CSS concept Flashes yellow if an error was detected that you can fix yourself with the CSS concept Does not light up when the system is OK If the event is still acute after a power cycle the indicator is activated after th...

Page 72: ...ad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 13570 001 fm 6 1 1 3 ID card You can pull out the ID card see figure 17 as far as it will go and push it back in again Figure 17 ID card in system unit The ID card contains various system information such as the product name serial number and order number ...

Page 73: ...s up when the management blade is active master Blinks when the management blade is defective Is not lit when the management blade is not active slave 2 LAN link indicators service LAN port Lights up green if a LAN connection exists Does not light up if no LAN connection exists 3 LAN activity indicators service LAN port Flashes yellow for a LAN transfer is in progress Does not light up for no LAN ...

Page 74: ...rverView Operations Manager or via the iRMC S2 S3 s Web interface 5 CSS indicator yellow Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself for reasons of precaution with the CSS concept Flashes yellow if an error was detected that you can fix yourself with the CSS concept Does not light up when the system is OK If the event is still acute after a pow...

Page 75: ...dicators Management LAN ports Lights up green if a LAN connection exists Does not light up if no LAN connection exists 8 10 LAN activity indicators Management LAN ports Flashes yellow when a LAN transfer is in progress Does not light up if no LAN transfer 11 Reset button ...

Page 76: ...er supply unit Figure 20 Indicators on the hot plug HE power supply unit 1 Error indicator for fan module 1 orange Lights up if fan module 1 is defective 2 Mains power indicator two color Flashes green when the system unit is switched off but still connected to the mains standby mode Lights up green when the system unit is switched on and is working properly Lights up yellow when a prospective err...

Page 77: ...rors The temperature is very high The power consumption is very high The current strength is very high 1 Error indicator for fan module 1 orange Lights up if fan module 1 is defective 2 Power indicator Flashes green when the system unit is switched off but still connected to the mains standby mode Lights up green when the system unit is switched on and the fan module is working properly 3 Error in...

Page 78: ...y is supplied to the connection blade Lights up orange Switch error Dark Power supply is not supplied to the connection blade 2 ID indicator blue Lit ID indicator was activated via the management blade Dark Normal operation A 1 Gbit Ethernet ports RJ45 with two integrated LAN status LEDs each 3 LAN transfer rate green orange Lights up orange LAN transfer rate 1 Gbit s Lights up green LAN transfer ...

Page 79: ...k power supply is not supplied to the connection blade Lights up orange Switch error Dark Power supply interrupted A 1 Gbit Ethernet ports for SFP modules for connecting fiber optic or copper cables 4x with two integrated status LEDs each 3 ERR Error indicator orange Dark No SFP transceiver error Lit SFP transceiver error Flashes SFP module not supported 4 LINK LAN connection indicator green Lit S...

Page 80: ...0 001 fm B 1 Gbit Ethernet ports 8x RJ45 with two integrated LAN status LEDs each 5 LAN transfer rate green orange Lights up orange LAN transfer rate 1 Gbit s Lights up green LAN transfer rate 100 Mbit s Dark LAN transfer rate 10 Mbit s 6 LAN connection indicator green Lit LAN connection available Flashes LAN connection active Dark LAN connection unavailable or deactivated ...

Page 81: ...lade Dark Normal operation 3 Stacking port 1 internal green Lit Stacking port 1 is available Flashes green Stacking port 1 is active Dark Stacking port 1 is not available 4 Stacking port 2 external green Lit Stacking port 2 is available Flashes green Stacking port 2 is active Dark Stacking port 2 is not available 5 Stacking green orange Lights up yellow Connection blade is stack master Flashes yel...

Page 82: ...or indicator orange Dark No SFP transceiver error Lit SFP transceiver error Flashes SFP module not supported 7 LINK LAN connection indicator green Lit SFP transceiver connection available Flashes SFP transceiver connection active Dark SFP transceiver connection not available or deactivated C 1 Gbit Ethernet ports RJ45 with two integrated LAN status LEDs each 8 LAN transfer rate green orange Lights...

Page 83: ... Connection blade error Dark Power supply is not supplied to the connection blade 2 Stack indicator green yellow future use Lit yellow Operating as a stack master Flashes yellow Operating failure as a stack master Lit green Operating as a stack slave Flashes green Operating failure as a stack slave or during master election process Dark No stacking 3 ID indicator blue Lit ID indicator was activate...

Page 84: ... for SFP modules for connection of fiber optic cables or for active twinax copper cables 8x each with two integrated status LEDs 4 ERR Error indicator orange Dark No SFP module error or SFP module not installed Lit SFP module error Flashes SFP module not supported 5 LINK LAN connection indicator green Lit LAN connection available Flashes LAN connection active Dark LAN connection unavailable or dea...

Page 85: ...en orange Dark Occurs in the following cases Server blade not present powered down or link is inactive Uplink port module not present Uplink port cable not connected One or both of the internal and or external links is down Lit green Both the internal and external links are up Flashes orange Occurs in the following cases Link protocol mismatch one indicator flashes orange Internal port speed confi...

Page 86: ...unning or is defective Lights up green Connection blade is running Lights up orange Boot phase one or more ports are offline restarting connection Flashes orange green Warning An error has occurred The LED can also flash during a test A External FC ports 8x Ports for FC SFP Multi Mode MMF or FC SFP Multi Mode MMF SFP modules B Status indicators for external FC ports green orange Dark No signal rec...

Page 87: ...ia the management blade 2 Status indicator green orange Dark Connection blade is powered off Lights up green Connection blade is powered on status OK Flashes orange Connection blade is powered on status fail 3 Status indicators for external FC ports green Lit FC link up A B External FC ports A 1 12 B 13 18 from left to right Ports for FC SFP Multi Mode MMF 4Gbit s or FC SFP Multi Mode MMF 8Gbit s ...

Page 88: ...reen Link is established and port is active Online is normal but no port activity Flickers green Port online data transport Flashes green Slow Port online but segmented Fast Internal loop Lights up orange Port with no sync light or signal carrier issue Flashes orange Slow 2 sec interval Port deactivated Fast 0 5 sec interval Port defective 2 Status indicators for external FC ports green orange Dar...

Page 89: ...ge Dark Connection blade is shut down and powered off normally Lights up green Connection blade is running Flashes green Boot phase connection blade is running diagnostics and initialization programs Flashes orange Warning Critical failures have occured e g The temperature has risen the normal thermal threshold The switch continues operating Lights up orange Warning Fatal failures have occured Ser...

Page 90: ...ables Fabric Extender Transceivers FET or other standard 10 Gigabit Ethernet optics such as 10Gbase SR 10Gbase LR and 10Gbase ER B Service port only for diagnostic purposes 1 ID ID indicator blue Lit ID indicator was activated via the management blade 2 Status indicator green Dark Connection blade is not running or is defective Lights up green Connection blade is running 3 Status indicators for ex...

Page 91: ...blade Flashes yellow Switch error 2 ID ID indicator blue Lit ID indicator was activated via the management blade 3 P Physical link status indicator of the external IB ports green Dark No signal reception IB port offline Lights up green IB port online 4L A Logical link status indicator of the external IB ports yellow Dark No signal reception Lights up yellow IB port online Flashes yellow Data trans...

Page 92: ...ts up green Power supply is supplied to the connection blade Flashes yellow Switch error 2 ID indicator blue ID Lit ID indicator was activated via the management blade 3 Physical link status indicator of the external IB ports green P Dark No signal reception IB port offline Lights up green IB port online 4 Logical link status indicator of the external IB ports yellow L A Dark No signal reception L...

Page 93: ... Gb 18 6 1 Status indicator green orange Lights up green Power supply is supplied to the connection blade Lights up orange Switch error Dark Power supply is not supplied to the connection blade 2 ID indicator blue Lit ID indicator was activated via the management blade Dark Normal operation 3 Reset button A 6 Gbit SAS connectors 6x 1 2 3 A ...

Page 94: ...g environment the server may operate improperly damage data etc Furthermore Fujitsu cannot be held responsible for any related damage malfunction or loss of data etc Be sure to wait for 10 seconds or more after shutdown before turning the server on After connecting power cable press the On Off button after it passes for more than 10 seconds Switching on the system unit Ê Press the On Off button on...

Page 95: ...can also switch off the system unit and the individual server blades via the Web interface of the management blade see manual PRIMERGY BX900 Blade Server Systems ServerView Management Blade S1 User Interface Description After power failure After a power failure the system unit will switch itself on again automatically and the server blades which were running prior to the power failure are automati...

Page 96: ...Server Systems ServerView Management Blade S1 User Interface Description Initial configuration with the Base Configuration Wizard Ê Make sure that the hardware installation of the system unit as described in chapter Hardware installation on page 47 Ê Press the On Off button on the ServerView local service panel position 4 in figure 16 on page 69 to switch on the system unit The management blade bo...

Page 97: ...he following default settings Language Date Time Identification Network Language Defines the language for the menu English or Japanese Date Time Contains the date time and the time zone and activates deactivates summer time Date and Time Settings Date Time Time Zone Daylight Saving Time enabled Import Import Settings 1 Import System Unit settings from USB memory device Select the settings to be im...

Page 98: ...me FCT tim_app tim_local work WALTER OBJ_DOKU 13570 001 fm Ident Identification Settings 1 Assign a name for the chassis System Name Assign a name for the rack where the chassis resides Rack Name Identification Settings 2 Assign a contact person for the system SystemContact Designate where the system resides System Location ...

Page 99: ...s IP Address is assigned by DHCP Assign IP Address manually IP Address Subnet Mask Gateway Management LAN Settings 2 IPv4 settings Obtain DNS Config from DHCP Assign primary and secondary Domain Servers DNS Server 1 DNS Server 2 Management LAN Settings 3 IPv6 settings IPv6 is enabled Obtain IP Address from DHCP IP Address Management LAN Settings 4 IPv6 settings Obtain DNS Config from DHCP Assign D...

Page 100: ...orized access PIN enable OFF PIN 0000 Check Ekeying Check This is a function which allows you to query the compatibility of the modules before startup and then activate partially activate or deactivate the module depending on the result For example you would not activate modules whose operating voltages or power consumption are not compatible with the system This test begins automatically after sw...

Page 101: ...with the Save button Save Settings All necessary configurations are done Do you really want to save your setting Save Export Stored settings can be saved on a USB storage medium In the next menu you can specify which configuration data you want to save to the USB storage medium You can export the following parameters Language Identification Network PIN Power Export Settings Do you like to export i...

Page 102: ...sing interior of the system unit should only be cleaned by authorized qualified personnel Do not use abrasive powder or detergents which dissolve plastic to clean the housing exterior Make sure that no liquid gets inside the device and that the ventilation slits on the system unit remain open Clean the keyboard and the mouse with a disinfecting cloth You may clean the housing surface of the system...

Page 103: ...u can activate the security functions of the management blade For more information see the manual PRIMERGY BX900 Blade Server Systems ServerView Management Blade S1 User Interface Description Further security options can be set in the BIOS setups and in the operating systems of the server blades For information on these see the BIOS Setup Utility for Reference Manuals or the operating manuals for ...

Page 104: ...104 Operating Manual BX900S2 Property and data protection cognitas Gesellschft für Technik Dokumentation mbH 2012 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 13571 001 fm ...

Page 105: ...ult Also make a list of any error messages that were displayed Ê Switch off the server Ê Contact our customer service team 8 1 System power indicator does not light up The system s power indicator see figure 16 on page 69 does not light up after you have switched on your system Power cable not connected correctly Ê Make sure that the power cable is correctly connected to the system s power supply ...

Page 106: ...ans in the power supply unit is not working properly Overcurrent Overvoltage or undervoltage The power supply unit is reaching the end of its life or its ambient thresholds are being exceeded Ê Check the status of the power supply unit and or the fan failure LEDs to identify the defective module and replace it see the PRIMERGY BX900 S2 System Unit Upgrade and Maintenance Manual One of the fans in ...

Page 107: ...hooting and tips 8 3 System switches itself off Server Management has detected an error Ê Check the error list of System Event Log in ServerView Operations Manager or in the management blade web interface and attempt to eliminate the error ...

Page 108: ...108 Operating Manual BX900S2 Troubleshooting and tips cognitas Gesellschft für Technik Dokumentation mbH 2012 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 13572 001 fm ...