background image

Upgrade and Maintenance Manual - English

FUJITSU Server PRIMERGY RX1330 M1

Upgrade and Maintenance Manual

May 2015

Summary of Contents for PRIMERGY RX1330 M1

Page 1: ...Upgrade and Maintenance Manual English FUJITSU Server PRIMERGY RX1330 M1 Upgrade and Maintenance Manual May 2015 ...

Page 2: ...pyright and Trademarks Copyright 2015 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights ...

Page 3: ...of these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The c...

Page 4: ...l Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferred ...

Page 5: ...nese market Shielded LAN cables should be used in this product Only for the Japanese market I Although described in this manual some sections do not apply to the Japanese market These options and routines include CSS Customer Self Service USB Flash Module UFM ...

Page 6: ...30 M1 Version history Issue number Reason for update 1 0 August 2014 Initial release 2 0 September 2014 Max load label removed from photos 3 0 May 2015 Section 11 2 7 note added cable tie for front VGA cable added iRMC microSD card added ...

Page 7: ... you need at hand 28 3 Important information 31 3 1 Safety instructions 31 3 2 ENERGY STAR 39 3 3 CE conformity 39 3 4 FCC Class A Compliance Statement 40 3 5 Environmental protection 41 4 Basic hardware procedures 43 4 1 Using diagnostics information 43 4 1 1 Locating the defective server 43 4 1 2 Determining the error class 44 4 1 2 1 Global Error indicator 44 4 1 2 2 Customer Self Service CSS i...

Page 8: ...watchdog functionality 64 5 1 2 1 Viewing boot watchdog settings 64 5 1 2 2 Configuring boot watchdog settings 65 5 1 3 Removing backup and optical disk media 66 5 1 4 Verifying and configuring the backup software solution 67 5 1 5 Note on server maintenance in a Multipath I O environment 67 5 1 6 Switching on the ID indicator 70 5 2 Completing the maintenance task 71 5 2 1 Updating or recovering ...

Page 9: ...7 2 After replacing the system board 89 5 2 18 Switching off the ID indicator 89 5 2 19 Performing a fan test after replacing a defective fan 89 6 Power supply 91 6 1 Basic information 92 6 2 Standard power supply 93 6 2 1 Replacing the standard power supply unit 93 6 2 1 1 Preliminary steps 93 6 2 1 2 Removing the defective standard power supply unit 93 6 2 1 3 Installing the new standard power s...

Page 10: ...mation 116 7 2 2 5 inch HDD SSD configurations 117 7 2 1 Equipping the 2 5 inch HDD SSD bays 117 7 2 2 Configuration with up to four HDD SSD modules 117 7 2 3 Configuration with up to eight HDD SSD modules 118 7 2 4 Configuration with up to 10 HDD SSD modules 119 7 2 5 Installing 2 5 inch HDD SSD modules 120 7 2 5 1 Preliminary steps 120 7 2 5 2 Removing a 2 5 inch HDD SSD dummy module 120 7 2 5 3...

Page 11: ...S expander board 138 7 2 10 4 Concluding steps 138 7 2 11 Upgrading configuration from up to four to up to eight 2 5 inch HDDs SSDs 139 7 2 11 1 Preliminary steps 139 7 2 11 2 Installing the second HDD backplane 139 7 2 11 3 Installing additional HDD SSD modules 140 7 2 11 4 Concluding steps 140 7 3 3 5 inch HDD configurations 141 7 3 1 Equipping the 3 5 inch HDD bays 141 7 3 2 Installing 3 5 inch...

Page 12: ... and backup units 157 9 1 Basic information 158 9 1 1 Equipping the PCIe slots 158 9 2 Handling slot brackets 161 9 2 1 Installing a slot bracket 161 9 2 2 Removing a slot bracket 163 9 2 2 1 Removing the slot bracket 163 9 3 Handling SFP transceiver modules 164 9 3 1 Installing SFP transceiver modules 164 9 3 2 Removing an SFP transceiver module 167 9 4 Expansion cards and riser cards 170 9 4 1 I...

Page 13: ...1 Preliminary steps 182 9 4 6 2 Installing the upgrade kit 183 9 5 Backup units BBU FBU 186 9 5 1 Installing a BBU 186 9 5 1 1 Preliminary steps 186 9 5 1 2 Preparing the BBU 187 9 5 1 3 Installing the BBU 189 9 5 1 4 Concluding steps 191 9 5 2 Installing an FBU 192 9 5 2 1 Preliminary steps 192 9 5 2 2 Preparing the FBU 193 9 5 2 3 Installing the FBU 194 9 5 2 4 Concluding steps 195 9 5 3 Removin...

Page 14: ... 1 2 Modes of operation 208 10 2 Installing a memory module 209 10 2 1 Preliminary steps 209 10 2 2 Selecting the memory slot 209 10 2 3 Installing a memory module 209 10 2 4 Concluding steps 210 10 3 Removing a memory module 210 10 3 1 Preliminary steps 210 10 3 2 Removing a memory module 211 10 3 3 Concluding steps 211 10 4 Replacing a memory module 211 10 4 1 Preliminary steps 211 10 4 2 Removi...

Page 15: ...2 Installing the ODD 227 12 2 1 Preliminary steps 227 12 2 2 Removing the dummy cover 227 12 2 3 Installing the ODD 228 12 2 4 Concluding steps 229 12 3 Removing the ODD 230 12 3 1 Preliminary steps 230 12 3 2 Removing the ODD 230 12 3 3 Installing the dummy cover 232 12 3 4 Concluding steps 232 12 4 Replacing the ODD 233 12 4 1 Preliminary steps 233 12 4 2 Removing the defective ODD 233 12 4 3 In...

Page 16: ... front VGA board 245 13 3 3 3 Installing the new front VGA board 245 13 3 3 4 Concluding steps 245 13 4 Front panel on QRL 10 x 2 5 inch HDD configuration 246 13 4 1 Replacing the front panel on QRL 246 13 4 1 1 Preliminary steps 246 13 4 1 2 Removing the front panel on QRL 247 13 4 1 3 Installing the front panel on QRL 249 13 4 1 4 Concluding steps 250 14 System board and components 251 14 1 Basi...

Page 17: ...M 267 14 4 2 3 Concluding steps 268 14 4 3 Replacing the TPM 269 14 4 3 1 Preliminary steps 269 14 4 3 2 Removing the defective TPM 270 14 4 3 3 Installing the new TPM 270 14 4 3 4 Concluding steps 270 14 5 iRMC microSD card 271 14 5 1 Installing the iRMC microSD card 271 14 5 1 1 Preliminary steps 271 14 5 1 2 Installing the iRMC microSD card 271 14 5 1 3 Concluding steps 272 14 5 2 Removing the ...

Page 18: ...er interior 298 16 2 Connectors and indicators 300 16 2 1 Connectors and indicators on the system board 300 16 2 1 1 Onboard connectors 300 16 2 1 2 Onboard indicators and controls 302 16 2 1 3 I O panel connectors 304 16 2 1 4 I O panel indicators 304 16 2 1 5 Indicators on hot plug power supply units slide in units 305 16 2 2 Indicators on the front panel 306 16 2 3 Indicators on the accessible ...

Page 19: ...ing defective hardware components This manual focuses on on site maintenance tasks It is recommended to prepare each service assignment following remote diagnostics procedures as described in the ServerView Suite Local Service Concept LSC manual see section Documents you need at hand on page 28 V CAUTION The document at hand comprises procedures of a wide range of complexity Check the profile of q...

Page 20: ...at are being emphasized Ê describes activities that must be performed in the order shown Abc indicates keys on the keyboard V CAUTION Pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates additional information notes and tips indicates the procedure category in terms of complexity ...

Page 21: ...dvanced Thermal Design option only components that support the higher operating range may be installed Further information on this is available in the configurator Installing optional components The operating manual of your server gives an introduction to server features and provides an overview of available hardware options Use the Fujitsu ServerView Suite management software and the iRMC web fro...

Page 22: ...hardware components that need to be replaced For further information on the controls and indicators of your server refer to the operating manual of your server and section Connectors and indicators on page 300 If the system has been powered off in order to replace a non hot plug unit a system of PRIMERGY diagnostic indicators guides you to the defective component The Indicate CSS button enables th...

Page 23: ...er Replaceable Units CRU Customer Replaceable Units are intended for customer self service and may be installed or replaced as hot plug components during operation I Components that the customer is entitled to replace may differ according to the service form in his country Hot plug components increase system availability and guarantee a high degree of data integrity and fail safe performance Proce...

Page 24: ...and system board will report defective Upgrade and Repair Units as customer replaceable CSS components Upgrade and repair procedures involve shutting down and opening the server V CAUTION The device may be seriously damaged or cause damage if it is opened without authorization or if repairs are attempted by unauthorized and untrained personnel Components that are handled as Upgrade Units Optical d...

Page 25: ...must be performed exclusively by Fujitsu service personnel or technicians trained by Fujitsu Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability Components that are handled as Field Replaceable Units Processor replacement SAS SATA backplanes Power distribution board Front panel module System board Standard power supply un...

Page 26: ...re described in section Starting the maintenance task on page 63 Rack removal disassembly yes making the server available removing the server from the rack if applicable Transport no Transporting the server to the service table where required depends on local customer conditions Maintenance procedures yes maintenance procedures including preliminary and concluding software tasks Transport no Retur...

Page 27: ...bit insert Screw Usage Type Phillips PH2 No 2 Slot brackets M3 x 3 5 mm silver C26192 Y10 C151 Phillips PH2 No 2 SAS expander board M3 x 4 5 mm silver C26192 Y10 C67 Phillips PH2 No 2 System board front panel M3 x 6 mm silver C26192 Y10 C68 Torx Plus 6 ODD latch M2 x 4 mm black C26192 Y10 C166 Phillips PH1 No 1 Front VGA M3 x 3 5 mm silver C26192 Y10 C102 Special bit insert TPM screw REM 3 x 15 mm...

Page 28: ...r the Japanese market please use the following address http jp fujitsu com platform server primergy manual Phillips PH1 No 1 UFM nylon screw M3 x 4 5 mm white C26192 Y10 C151 Phillips PH1 No 1 TFM module M2 5 x 4 mm silver C26192 Y10 C103 Document Description Quick Start Hardware FUJITSU Server PRIMERGY RX1330 M1 leaflet Quick installation poster for initial operation available online ServerView Q...

Page 29: ... Manager Server Management user guide iRMC S4 Integrated Remote Management Controller user guide ServerView embedded Lifecycle Management eLCM user guide Illustrated Spares catalog Spare parts identification and information system EMEA market only available for online use or download Windows OS at http manuals ts fujitsu com illustrated_spares or from the CSS component view of the ServerView Opera...

Page 30: ...nuals ts fujitsu com under x86Servers Expansion Cards Storage Adapters For the Japanese market please use the following address http jp fujitsu com platform server primergy manual Third party documentation Operating system documentation online help Peripherals documentation Document Description Table 3 Documentation you need at hand ...

Page 31: ...s a person who is trained to install the server including hardware and software Repairs to the device that do not relate to CSS failures shall be performed by service personnel Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability Any failure to observe the guidelines in this manual and any improper repairs could expose the...

Page 32: ...type A connectors The unit automatically adjusts itself to a mains voltage in a range of 100 V 240 V Ensure that the local mains voltage lies within these limits This device must only be connected to properly grounded power outlets or connected to the grounded rack internal power distribution system with tested and approved power cords Ensure that the device is connected to a properly grounded pow...

Page 33: ...casing is completely assembled and the rear covers for the installation slots have been fitted electric shock cooling fire protection interference suppression Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals If you install other expansions they may damage the system or violate...

Page 34: ...stallation detaching internal options in former device position To use a screw of the different kind can cause a breakdown of equipment The installation indicated on this document is sometimes changed to the kind of possible options without notice Batteries Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type ...

Page 35: ...drive equipment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck High humidity and airborne dust levels are to be avoided Electric shocks and or server failures may be caused by liquids such as water or metallic items such as paper clips entering a drive Shocks and vibrations are also to be avoided Do not insert any objects other t...

Page 36: ...case wipe the CD DVD BD with a soft dry cloth then let it air dry Do not dry the CD DVD BD using devices such as a hair dryer To avoid dust damage and deformation keep the CD DVD BD in its case whenever it is not in use Do not store CDs DVDs BDs at high temperatures Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided I You can prevent damage from the optical dri...

Page 37: ...ust always discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or conducti...

Page 38: ...k using the handles on the front panel When connecting and disconnecting cables observe the relevant instructions in the Important Information chapter of the technical manual for the corresponding rack The technical manual is supplied with the corresponding rack When installing the rack make sure that the anti tilt protection is correctly fitted For safety reasons no more than one unit may be remo...

Page 39: ...ses the properties guaranteed by ENERGY STAR can no longer be assured The ServerView Operations Manager user guide contains instructions for reading out measurement values including those relating to current energy consumption and air temperatures Either the Performance Monitor or the Task Manager can be used to read out CPU utilization levels The system complies with the requirements of the EC di...

Page 40: ...e harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the ...

Page 41: ... constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting the system If possible the equipment should only be transported in its original packaging Information on handling c...

Page 42: ...ing used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 525 1410 Fax 49 5251 525 32 1410 The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EC on waste electrical and electronic equipment WEEE This directive set...

Page 43: ...n Illustrated Spares catalogs are available online at http manuals ts fujitsu com illustrated_spares EMEA market only Perform the following diagnostics procedures to identify defective servers and components 4 1 1 Locating the defective server When working in a datacenter environment switch on the ID indicator on the front and rear connector panels of the server for easy identification Ê Press the...

Page 44: ...el needs to be dispatched to replace the part I The indicators also light up in standby mode and after a server restart due to a power failure 4 1 2 1 Global Error indicator Ê Check the Global Error indicator on the front panel of the server Ê For further diagnostics proceed as follows Hardware errors Check the System Event Log SEL as described in section Viewing the SEL on page 81 Software agent ...

Page 45: ...he system I It is mandatory to disconnect power cords in order to use the Indicate CSS functionality Ê Press the Indicate CSS button to highlight defective components see section Onboard indicators and controls on page 302 I In addition to local diagnostic indicators CSS or Global Error LEDs indicate if the defective component is a customer replaceable unit or if a service technician needs to be d...

Page 46: ... an ACPI compliant operating system pressing the On Off button will perform a graceful shutdown Ê Switch on the ID indicator on the front and rear connector panels of the server as described in section Locating the defective server on page 43 4 3 Disconnecting the server from the mains Standard power supply Figure 2 Unlocking the cable tie of a standard power supply unit Ê Pull out on the locking ...

Page 47: ...ess to the component V CAUTION Only for non hot plug components Before removing or attaching covers turn off the server all peripheral devices and any other connected devices Also unplug all power cords from the outlet Failure to do so can cause electric shock The top cover must be replaced as soon as possible for purposes of cooling to comply with EMC regulations regulations regarding electromagn...

Page 48: ...es when sliding out the server or pushing it back Failure to do so may cause injury For further safety information please refer to chapter Important information on page 31 Ê Remove all remaining external cables from the rear connector panel and expansion cards Figure 4 Extending the server out of the rack Ê Fold down the two quick release levers 1 Ê Pull the server out of the rack until it locks i...

Page 49: ...k cabinet For the Japanese market please refer to 安全上のご注意 Additionally a lifter is required in the following cases The server weighs more than 50 kg The server weighs more than 21 kg and is installed above the height of 25 U When using a lifter this removal procedure needs to be carried out by maintenance personnel For configurations below 32 kg At least two people are needed to lift the server ou...

Page 50: ...ce Manual RX1330 M1 Basic hardware procedures Figure 5 Removing the server from the rack Ê Release the locking bars on both telescopic rails 1 Ê Lift the server out of the telescopic rails 2 and place it on an even surface 햲 햳 ...

Page 51: ...nual 51 Basic hardware procedures 4 4 3 Removing the top cover Figure 6 Removing the top cover Ê Push green touch points inside 1 Ê Push the top cover as far as it will go in the direction of the arrow 2 Ê Lift off the top cover upward 3 ...

Page 52: ...soon as possible for purposes of cooling to comply with EMC regulations regulations regarding electromagnetic compatibility and to prevent fires For further safety information please refer to chapter Important information on page 31 4 5 1 Installing the top cover Figure 7 Attaching the top cover Ê Place the top cover on the server 1 Ê Push the top cover as far as it will go in the direction of the...

Page 53: ...ghs more than 50 kg The server weighs more than 21 kg and is to be installed above the height of 25 U When using a lifter this installation procedure needs to be carried out by maintenance personnel For configurations below 32 kg At least two people are needed to lift the server into the rack cabinet For configurations below 55 kg At least three people are needed to lift the server into the rack c...

Page 54: ...The telescopic rails must click into place so that they can no longer be moved Ê At a slight angle lower the server onto the rear mounting point on the telescopic rails 2 Ê Fold down the server while pressing the rail to the server side 3 Ensure that all six rack mounting bolts are properly seated in the mounting points on the telescopic rails and that the locking bars engage 4 햲 햲 햴 햵 햳 햳 ...

Page 55: ... quick release levers engage 3 V CAUTION Be careful with your fingers You can pinch them when the quick release levers change to the release position Ê Reconnect all cables except the power cord to the server rear 4 6 Connecting the server to the mains V CAUTION The server supports a mains voltage in the range of 100 V 240 V You may only operate the server if its rated voltage range corresponds to...

Page 56: ...he insulated connector cannot now be disconnected from the server accidentally Redundant power supply Ê If applicable connect the mains plugs to power outlets of the rack socket strip I To provide true phase redundancy the second power supply unit should be connected to a different AC power source from the other power supply unit If one AC power source should fail the server will still continue to...

Page 57: ...he server make sure the top cover is closed In order to comply with applicable EMC regulations regulations on electromagnetic compatibility and satisfy cooling requirements the server must not run while the top cover is removed For further safety information please refer to chapter Important information on page 31 Ê Press the On Off button to start up the server Ê Ensure that the power on indicato...

Page 58: ...58 Upgrade and Maintenance Manual RX1330 M1 Basic hardware procedures 4 8 Handling riser modules 4 8 1 Removing a riser module Figure 12 Removing the riser module 1 Figure 13 Removing the riser module 2 ...

Page 59: ...ance Manual 59 Basic hardware procedures Figure 14 Removing the riser module 3 Figure 15 Removing the full height riser module Ê If necessary disconnect cables from the other components Ê Carefully pull out the riser module upward ...

Page 60: ... and Maintenance Manual RX1330 M1 Basic hardware procedures 4 8 2 Installing a riser module Figure 16 Installing the riser module 1 Figure 17 Installing the riser module 2 Figure 18 Installing the riser module 3 ...

Page 61: ...ll height riser module Ê Insert the riser card into the system board slot and press down the green touch points see circles V CAUTION Valid for the full height riser module Make sure that the EMC springs make contact correctly see close ups Ê If necessary connect the cables to the other components ...

Page 62: ...62 Upgrade and Maintenance Manual RX1330 M1 Basic hardware procedures ...

Page 63: ...tion without decrypting the drive Windows is installed on Suspend BitLocker before modifying the server s hardware configuration or startup files Resume BitLocker again after the maintenance procedure is complete V CAUTION With BitLocker features enabled modifying the system configuration hardware or firmware settings may render the system inaccessible The system may enter Recovery Mode and requir...

Page 64: ...data will not be protected while BitLocker is suspended I In order to determine which features are accessible through the BitLocker setup wizard it may be necessary to modify the BitLocker Group Policy settings For further information on how to suspend BitLocker drive encryption please refer to the Microsoft TechNet library at http technet microsoft com library cc731549 aspx Fujitsu service partne...

Page 65: ...e Viewing boot watchdog settings in ServerView Operations Manager Ê In ServerView Operations Manager Single System View select Maintenance from the Information Operation menu Ê Under ASR R select the Watchdog tab to obtain detailed information about the current watchdog status time out intervals and actions that are triggered if watchdog time outs are exceeded I For more detailed information refer...

Page 66: ...nt Controller user guide 5 1 3 Removing backup and optical disk media Ê Ask the system administrator to eject all remaining backup or optical media from the backup or optical disk drive before removing it from the server Ê If the backup media cannot be ejected by conventional means and it is mandatory that the cartridge be removed prior to returning the drive for repair or disposing it a manual ta...

Page 67: ...ujitsu service partners from the Fujitsu Extranet pages 5 1 5 Note on server maintenance in a Multipath I O environment When booting your server offline from the ServerView Suite DVD to perform an offline BIOS firmware update using the ServerView Update DVD or collect diagnostic data using PrimeCollect in a Multipath I O environment there is a risk of damaging the system configuration which may le...

Page 68: ...in the Local System Update for PRIMERGY Servers user guide Ê Boot the server from the prepared Update DVD or USB stick DVD Ê Switch on the server Ê Right after switching on the server insert the Update DVD into the DVD drive and close the tray USB Ê Connect the USB stick to the server Ê Switch on the server If the server does not boot from DVD or USB stick proceed as follows Ê Reboot the server e ...

Page 69: ...er e g by pressing the reset button on the front or switching the server off and then on again after a few seconds Ê Once the server has been started press F12 to enter the boot menu Ê Use the Ê and Ë cursor keys to select your DVD drive as boot device and press ENTER The server will now boot from the ServerView Suite DVD Ê After the boot process is complete select your preferred GUI language Ê In...

Page 70: ...cept LSC and Integrated Remote Management Controller user guides Using the ID button on the front panel Ê Press the ID button on the front panel to switch on the system identification LEDs I For further information refer to section Indicators on the front panel on page 306 Using the iRMC web frontend Ê Enter the ServerView iRMC web frontend Ê Under System Overview click Identify LED On to switch o...

Page 71: ...assume responsibility for any damage done to the server or for the loss of any data resulting from BIOS updates 5 2 1 1 Updating or recovering the system board BIOS BIOS flash procedure Ê Perform the BIOS flash procedure as described in your server s BIOS Setup Utility reference manual BIOS recovery procedure Ê Perform the BIOS recovery procedure as described in your server s BIOS Setup Utility re...

Page 72: ...k after flashing disconnect the system from the mains and reconnect it again Ê After completion of the flash process remove the USB stick and restart the server iRMC recovery procedure Ê Prepare a USB stick including the bootable iRMC firmware update image Ê Ensure that the server has been shut down and disconnected from the mains as described in section Disconnecting the server from the mains on ...

Page 73: ...non default settings when replacing the system board a backup copy of important system configuration data is automatically stored from the system board NVRAM to the Chassis ID EPROM After replacing the system board the backup data is restored from the Chassis ID board to the new system board In order to verify whether the backup or restore process has been successful check the System Event Log SEL...

Page 74: ...ttp jp fujitsu com platform server primergy downloads Japanese market I Fujitsu does not assume responsibility for any damage done to the server or for the loss of any data resulting from firmware updates For the Japanese market follow the instructions provided separately Using the ServerView Update Manager For a detailed description on how to update the RAID controller firmware using the ServerVi...

Page 75: ...nently e g in case of a boot controller that may require frequent setup or temporarily for one time configuration When permanently enabling a controllers s Option ROM keep in mind that only two Option ROMs can be activated in the system board BIOS at a time Ê Enter the BIOS Ê From the Advanced menu select Option ROM Configuration Ê Identify the desired PCI slot and set its Launch Slot OpROM settin...

Page 76: ... for the following backup software solutions Netvault for Windows ARCServe BackupExec I Procedures may differ depending on the backup software For details refer to the dedicated documentation provided separately Further information on suitable backup software solutions and related documentation is available to Fujitsu service partners from the Fujitsu Extranet pages Re enabling backup drives If a ...

Page 77: ...Ê Exit the BIOS 5 2 6 2 Resetting the boot retry counter The boot retry counter should be reset to its original value concluding every service task I Please note if the customer does not know about the original boot retry values If the system boots up and no further errors occur within 6 hours after that successful boot attempt the boot retry counter will automatically be reset to its default valu...

Page 78: ...vailable under ASR R Options Ê Under Retry counter max specify the maximum number of attempts to boot the operating system 0 to 7 Ê Under Retry counter the current number of remaining boot attempts is displayed Overwrite this value with the maximum number of boot attempts specified above in order to reset the boot retry counter Ê Click Apply for the changes to take effect I For detailed informatio...

Page 79: ...timeout delay Ê Click Apply for the changes to take effect I For detailed information on iRMC settings refer to the Integrated Remote Management Controller user guide 5 2 8 Enabling replaced components in the system BIOS When a processor an expansion card or a memory module fails the defective component will be set to Disabled or Failed in the system BIOS The server will then reboot with only the ...

Page 80: ...ge 208 After replacing the defective module s the memory operation mode is automatically reset to its original state It is recommended to verify that the operation mode has been correctly Ê Enter the BIOS Ê Select the Advanced menu Ê Under Memory Status verify that none of the memory modules are marked as Failed Ê Save your changes if applicable and exit the BIOS I For detailed information on how ...

Page 81: ...Time to UTC Universal Time Coordinated instead Greenwich Mean Time GMT can be considered equivalent to UTC Ê Save your changes and exit the BIOS I For detailed information on how to access the BIOS and modify settings refer to the corresponding BIOS Setup Utility reference manual 5 2 11 Viewing and clearing the System Event Log SEL 5 2 11 1 Viewing the SEL You can view the System Event Log SEL usi...

Page 82: ...s Manager refer to the ServerView Operations Manager Server Management user guide Viewing the SEL using the iRMC web frontend Ê Enter the ServerView iRMC web frontend Ê Select the Event Log and choose the Internal Event Log submenu Ê Under Internal Event Log Content the SEL is being displayed In order to filter the list select the check boxes next to the desired event types and press Apply for the...

Page 83: ...ition file on the client system Use the following information as reference Ask the system administrator to change the definition file Ê After replacing a network controller or the system board switch on and boot the server as described in section Switching on the server on page 57 kudzu the hardware configuration tool for Red Hat Linux will launch at boot and detect the new and or changed hardware...

Page 84: ...ecovery key when rebooting the server after the maintenance task However if BitLocker functionality has not been suspended Windows will enter recovery mode and ask you to input recovery key for further booting Ê In this case ask the system administrator to enter the recovery key in order to boot the operating system Ê Ask the system administrator to enable the previously suspended BitLocker protec...

Page 85: ... Wait until the progress bar has reached at least one percent Ê Inform the customer about the remaining rebuild time based on the displayed duration estimate Figure 20 Progress bar RAID array rebuild V CAUTION The system is now operational however data redundancy will not be available until the RAID array rebuild is complete Depending on the hard disk drive capacity the overall process can take up...

Page 86: ...ller s Option ROM in the system board BIOS as described in section Enabling Option ROM scan on page 75 Ê Restart the server Ê During boot as soon as the Emulex BIOS utility option appears press ALT E or CTRL E Ê Under Emulex Adapters in the System you will find all available Emulex adapters and their WWN addresses Ê Note down the new 16 digit WWN address Ê Press Esc to exit the Emulex BIOS utility...

Page 87: ...vironment and to enable server installation using the ServerView Installation Manager system data needs to be complete and correct After replacing the Chassis ID EPROM system information has to be entered using the Chassis ID Prom tool The tool and further instructions are available to maintenance personnel from the Fujitsu Technology Solutions Extranet https partners ts fujitsu com com service ps...

Page 88: ... LAN team I For more detailed information refer to the ServerView Operations Manager Server Management user guide 5 2 17 1 After replacing upgrading LAN controllers Please note when re using a replaced LAN controller Ê Confirm with the customer whether the LAN controller you have replaced has been used as part of a LAN teaming configuration Ê If LAN teaming has been active you will need to restore...

Page 89: ...e server on page 43 or to the ServerView Suite Local Service Concept LSC and Integrated Remote Management Controller user guides Using the ID button on the front panel Ê Press the ID button on the front panel to switch off the ID indicators Using the iRMC web frontend Ê Enter the ServerView iRMC web frontend Ê Under System Overview click Identify LED Off to switch off the ID indicators Using Serve...

Page 90: ... of the Server list tab select the server to be configured Ê In the right hand side of the window specify the details on the selected server and confirm your entries by clicking GO In the left hand section of the window the Configuration tab is being activated Ê In the navigation area of the Configuration tab select Other Settings Ê Under Daily Fan Test set the daily fan test time to a few minutes...

Page 91: ...wer supply unit When installing the power supply unit be sure to confirm that the connector of the power supply unit is not damaged or bent Do not insert your hands in the power supply unit slot when removing the power supply unit Doing so may cause electric shock If the power supply unit is hard to remove do not pull out it by force The power supply unit is heavy so handle it carefully If you dro...

Page 92: ... adjusts automatically to any mains voltage in the range of 100 V 240 V Besides the power supply unit a second power supply unit can be installed optionally to serve as a redundant power supply If one power supply unit fails the second power supply unit in the redundant configuration ensures operation can continue uninterrupted and the defective power supply unit can be replaced during operation h...

Page 93: ...functionality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 6 2 1 2 Removing the defective standard power supply unit Figure 21 Disconnecting the power cables Ê Disconnect the two power cables from the system board connectors PC98 and PWR1 Field Replaceable Unit FRU Hardware 10 minutes Tools Philli...

Page 94: ...ly Figure 22 Removing the screws Ê Remove the two screws see circles Figure 23 Taking out the standard power supply unit Ê Remove the two screws 1 Ê Pull the power supply unit a few centimeters toward the inside 2 Ê Take the power supply unit out upward 3 ...

Page 95: ...y unit Figure 24 Inserting the standard power supply unit Ê Insert the power supply unit into the bay 1 Ê Push the power supply unit toward the adapter plate 2 Ê Fasten the power supply unit with two screws in the chassis 3 Ê Attach the power supply unit with two screws to the adapter plate see figure 22 ...

Page 96: ...g on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 Ê Performing a fan test after replacing a defective fan on page 89 V CAUTION Except for Japanese market After replacing the power supply unit a fan calibration must be started for the PSU fan You will find the description for this procedure in the manual S...

Page 97: ...ver Figure 27 Removing a dummy cover Ê Press in on both release latches 1 and remove the dummy cover 2 V CAUTION Keep the dummy cover for future use If a power supply unit is removed and not immediately replaced by a new one a dummy cover must be reinstalled in the bay to comply with applicable EMC regulations and satisfy cooling requirements Customer Replaceable Unit CRU Hardware 5 minutes Tools ...

Page 98: ...re 29 Installing the hot plug power supply unit Ê Push the power supply unit into its bay 1 as far as it will go until the locking latch snaps in place Ê If applicable fold down the handle on the power supply unit 2 I Make sure that the power supply unit engages correctly in the bay and is locked in position This is the only way to prevent the power supply unit from sliding out of its bay and bein...

Page 99: ...de and Maintenance Manual 99 Power supply Figure 30 Installing the cable tie Ê Push the cable tie into the corresponding hole until it clicks in 6 3 1 4 Concluding steps Ê Connecting the server to the mains on page 55 ...

Page 100: ... additional tasks are needed due to an interference between CMA stopper and the power supply units Figure 31 Unlocking the CMA stopper Ê Push the lock spring inward to unlock the CMA stopper V CAUTION In case of not enough space at the under side unlock the CMA stopper of the server below and pull out the CMA to the rear side Customer Replaceable Unit CRU Hardware 5 minutes Tools tool less ...

Page 101: ...stopper with the mounted crossbar Ê Hold the CMA stopper the crossbar and the CMA including cables in the one hand Figure 33 Removing the power supply unit Ê Remove the power supply unit and install the dummy cover carefully Ê Mount the complete assembly CMA stopper the crossbar and the CMA again into the rail ...

Page 102: ...ains on page 46 Figure 34 Unlocking and removing the hot plug power supply unit Ê Push the handle of the power supply unit halfway upward in the direction of the arrow 1 Ê Push the lock in direction of the arrow 2 Ê Grip the handle and pull out the power supply unit in the direction of the arrow 3 V CAUTION Never leave the bay for the power supply unit empty for more than two minutes during operat...

Page 103: ...ush the dummy cover into its bay until it locks in place V CAUTION Always install dummy covers into unused bays to comply with applicable EMC regulations and satisfy cooling requirements 6 3 3 Replacing a hot plug power supply unit V CAUTION When replacing a power supply unit in a non redundant PSU configuration the server must be switched off first Replace the power supply unit after specifying t...

Page 104: ...stall the new power supply unit carefully Ê Mount the complete assembly CMA stopper the crossbar and the CMA again into the rail 6 3 3 1 Preliminary steps Ê Locating the defective server on page 43 Ê Locating the defective component on page 45 Ê Check which power supply unit is defective A power supply unit is defective when the indicator 1 in figure 228 lights orange For more information see sect...

Page 105: ...the mains on page 55 Ê Only when replacing a power supply unit in a non redundant configuration Switching on the server on page 57 Ê Performing a fan test after replacing a defective fan on page 89 6 3 4 Replacing the power distribution board 6 3 4 1 Preliminary steps Ê Locating the defective server on page 43 Ê Suspending BitLocker functionality on page 63 Ê Shutting down the server on page 45 Ê ...

Page 106: ... supply units as described in section Removing a hot plug power supply unit on page 102 Figure 36 Removing the power distribution board Ê Disconnect the two power cables from the power distribution board 1 Ê Remove the screw see circle Ê Slide the power distribution board out of the guidings of the chassis 2 and take it out upward 3 ...

Page 107: ...ution board Ê Insert the power distribution board 1 and slide it in the guidings of the chassis 2 Ê Fasten the power distribution board with one screw see circle Ê Connect the two power cables to the power distribution board 3 Check if the flat cable is correctly seated under the edge of the power distribution board Figure 38 Routing the flat cable ...

Page 108: ...e replaced by a redundant power supply The redundant power supply consists of up to two power supply units slide in units The upgrade kit contains only one power supply unit for power supply redundancy the second power supply unit must be additionally ordered The upgrade kit for the redundant power supply consists of the following parts PSU cage with power distribution board two power cables one h...

Page 109: ...e component on page 47 6 4 2 Removing the standard power supply unit Ê Remove the power supply unit as described in section Removing the defective standard power supply unit on page 93 Figure 39 Removing the adapter plate Ê Remove the screw see circle which attach the adapter plate of the power supply unit to the housing Ê Push the adapter plate a few centimeters inward to detach it from the two b...

Page 110: ... 3 Installing the upgrade kit Installing the PSU cage Figure 40 Positions of the bolts Figure 41 Inserting the PSU cage Ê Insert the PSU cage in the housing and push it to the rear side V CAUTION The PSU cage must engage in the five bolts positions see figure 40 ...

Page 111: ...ing the PSU cage Ê Fasten the PSU cage with one screw Installing the power distribution board Figure 43 Folding the flat cable Ê Fold the flat cable as shown Ê Install the power distribution board as described in section Installing the new power distribution board on page 107 ...

Page 112: ...1 Installing hot plug power supply unit and dummy cover Ê Install the power supply unit as described in section Installing a hot plug power supply unit on page 98 I The power supply unit must be installed in the first bay left bay seen from rear side The dummy cover must be installed in the second bay Ê Install the dummy cover as described in section Installing the dummy cover on page 103 ...

Page 113: ...upply Installing the additional fan module Figure 45 Removing the sponge Ê Remove the sponge Figure 46 Routing fan cable Ê Thread the fan cable through the opening of the fan cage and insert the fan module Notice the direction of the fan label see circle ...

Page 114: ...s down the four rubber pins until they engage see circles Ê Connect the fan cable to connector FAN5 on the system board 6 4 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 ...

Page 115: ...epending on the OS you can configure the write cache settings for the hard disk drives If a power failure should occur while the write cache is enabled cached data may be lost When disposing of transferring or returning a hard disk drive or solid state drive wipe out the data on the drive for your own security Rough handling of hard disk drives may damage the stored data To cope with any unexpecte...

Page 116: ...le is connected to the HDD backplane wirelessly This allows HDD modules to be plugged in or pulled out easily Hybrid configurations of SAS and SATA HDD modules are not supported 2 5 inch HDD SSD subsystem Up to four one HDD backplane eight two HDD backplanes or ten one HDD backplane 2 5 inch SAS SATA HDD SSD modules can be installed Each HDD SSD module can accommodate a SAS SATA hard disk drive or...

Page 117: ...osition 1 Free bays must be equipped with a dummy module 7 2 2 Configuration with up to four HDD SSD modules Mounting order Figure 48 Mounting order with up to four 2 5 inch HDDs SSDs HDD SSD naming scheme Figure 49 Naming scheme with up to four 2 5 inch HDDs SSDs I The HDD SSD numbering as listed in the ServerView RAID Manager differs from the HDD mounting order Position Logical drive number Serv...

Page 118: ...ng scheme Figure 51 Naming scheme with up to eight 2 5 inch HDDs SSDs I The HDD SSD numbering as listed in the ServerView RAID Manager differs from the HDD SSD mounting order Position Logical drive number ServerView RAID Manager display name 1 0 HDD vendor name 0 2 1 HDD vendor name 1 3 2 HDD vendor name 2 4 3 HDD vendor name 3 5 4 HDD vendor name 4 6 5 HDD vendor name 5 7 6 HDD vendor name 6 8 7 ...

Page 119: ...ng scheme with up to ten 2 5 inch HDDs SSDs I The HDD SSD numbering as listed in the ServerView RAID Manager differs from the HDD SSD mounting order Position Logical drive number ServerView RAID Manager display name 1 0 HDD vendor name 0 2 1 HDD vendor name 1 3 2 HDD vendor name 2 4 3 HDD vendor name 3 5 4 HDD vendor name 4 6 5 HDD vendor name 5 7 6 HDD vendor name 6 8 7 HDD vendor name 7 9 8 HDD ...

Page 120: ...2 Removing a 2 5 inch HDD SSD dummy module I In configuration with only one 4 x 2 5 inch HDD backplane dummy locks are installed to make it impossible to equip the bays with no HDD backplane behind Figure 54 Removing dummy lock Ê Only valid after upgrading the server with the second HDD backplane pull the dummy lock out of the dummy cover Please be aware that the dummy lock can be damaged Customer...

Page 121: ...mmy module out of its bay 2 V CAUTION Save the dummy module for future use Always replace dummy modules into unused HDD SSD bays to comply with applicable EMC regulations and satisfy cooling requirements 7 2 5 3 Installing a 2 5 inch HDD SSD module Figure 56 Opening the 2 5 inch HDD SSD module locking lever Ê Pinch the green locking clip 1 and open the locking lever 2 ...

Page 122: ...ive in place 2 7 2 5 4 Concluding steps Ê Performing a RAID array rebuild on page 85 7 2 6 Removing 2 5 inch HDD SSD modules 7 2 6 1 Preliminary steps Ê If the HDD SSD module to be removed is combined into a RAID array please proceed as follows Customer Replaceable Unit CRU Hardware 5 minutes Tools tool less RAID level Procedure RAID 0 Only remove an HDD module combined in a RAID 0 array if defect...

Page 123: ...ee figure 56 Ê Pull the HDD SSD module out a few centimeters Ê Wait about 30 seconds to allow the hard disk drive to spin down I This is not necessary when removing a solid state drive I This period is necessary for the RAID controller to recognize that an HDD module has been removed and for the hard disk drive to come to a stop Ê Pull the HDD SSD module completely out of its bay RAID 1 RAID 5 Rem...

Page 124: ...satisfy cooling requirements Figure 58 Installing a 2 5 inch dummy module Ê Push the dummy module into the empty bay until it engages 7 2 6 4 Concluding steps No steps needed 7 2 7 Replacing a 2 5 inch HDD SSD module V CAUTION Only remove an HDD SSD module during operation if the drive is not currently being accessed Observe the indicators for the corresponding HDD SSD modules see section Indicato...

Page 125: ...r original bays later If this is not done existing data can be lost 7 2 7 1 Preliminary steps Ê Locating the defective server on page 43 Ê Locating the defective component on page 45 Only applicable for removing intact HDD SSD modules Ê Before removing a non defective HDD SSD module put the drive into Offline mode using your RAID configuration software 7 2 7 2 Removing the defective 2 5 inch HDD S...

Page 126: ...The HDD SSD modules need not to be removed But if you want to remove them nevertheless check if all HDD SSD modules are uniquely identified so that you can reinsert them into their original bays 7 2 8 2 Removing the defective 4 x 2 5 inch HDD backplane I For configurations with up to four 2 5 inch HDDs SSDs please refer to section Left side 4 x 2 5 inch HDD backplane A3C40157852 on page 127 For co...

Page 127: ...from the ODD see orange circle Ê If applicable pull the ODD latch upward 1 until it disengages and push the ODD somewhat in direction of the front side 2 Ê Disconnect all cables from the HDD backplane see blue circles I If applicable remove the OOB cable from the HDD backplane too Figure 60 Removing the 4 x 2 5 inch HDD backplane Ê Pull the HDD backplane upward until the six hooks disengage see ci...

Page 128: ...too Ê Pull the HDD backplane upward until the four hooks disengage see circles Ê Take out the HDD backplane 7 2 8 3 Installing the new 4 x 2 5 inch HDD backplane I For configurations with up to four 2 5 inch HDDs SSDs please refer to section Left side 4 x 2 5 inch HDD backplane A3C40157852 on page 129 For configurations with up to eight 2 5 inch HDDs SSDs please refer to section Left side 4 x 2 5 ...

Page 129: ...HDD backplane A3C40157852 Figure 62 Installing the 4 x 2 5 inch HDD backplane Ê Position the HDD backplane on the six hooks see circles Ê Push the HDD backplane downward Make sure that the lower cant of the HDD backplane fits in the guides A V CAUTION Ensure that none of the cables are strained or damaged ...

Page 130: ...il the ODD latch engages see orange arrow Ê Connect the following cables to the ODD and the HDD backplane 1 power cable to ODD if applicable 2 SATA cable to ODD if applicable 3 SAS cable to connector X5 on the HDD backplane 4 power cable to connector PWR on the HDD backplane I If applicable connect the OOB cable to connector SMBus on the HDD backplane For the cable plan see section Cabling on page...

Page 131: ...Connect the following cables to the HDD backplane 1 SAS cable to connector X5 on the HDD backplane 2 power cable to connector PWR on the HDD backplane I If applicable connect the OOB cable to connector SMBus on the HDD backplane For the cable plan see section Cabling on page 285 7 2 8 4 Concluding steps Ê Insert all HDD SSD modules see section Installing 2 5 inch HDD SSD modules on page 120 I Make...

Page 132: ...nd pull them out a few centimeters see section Removing 2 5 inch HDD SSD modules on page 122 I The HDD SSD modules need not to be removed But if you want to remove them nevertheless check if all HDD SSD modules are uniquely identified so that you can reinsert them into their original bays 7 2 9 2 Removing the SAS expander board Figure 65 Disconnecting power cable from the HDD backplane Ê Disconnec...

Page 133: ...enance Manual 133 Hard disk drives solid state drives Figure 66 Disconnecting SAS cables Ê Disconnect the two SAS cables from the SAS expander board Figure 67 Removing the SAS expander board A Ê Remove the two screws see circles ...

Page 134: ...the HDD backplane and remove it V CAUTION Lift up the SAS expander board while removing it in order to prevent the components to be damaged by the stand offs of the chassis 7 2 9 3 Removing the defective 10 x 2 5 inch HDD backplane Figure 69 Removing the 10 x 2 5 inch HDD backplane Ê Pull the HDD backplane upward until the six hooks disengage see circles Ê Take out the HDD backplane ...

Page 135: ...hooks see circles Ê Push the HDD backplane downward Make sure that the lower cant of the HDD backplane fits in the guides A 7 2 9 5 Installing the SAS expander board Figure 71 Installing the SAS expander board A Ê Insert the SAS expander board into the two connectors of the HDD backplane V CAUTION Lift up the SAS expander board while inserting it in order to prevent the components to be damaged by...

Page 136: ... the SAS expander board B Ê Fasten the SAS expander board with two screws see circles Figure 73 Connecting SAS cables Ê Connect the two SAS cables to the SAS expander board 1 from SAS controller connector MLC1 to SAS expander board 2 from SAS controller connector MLC2 to SAS expander board MLC 1 MLC 2 ...

Page 137: ...e to the HDD backplane 7 2 9 6 Concluding steps Ê Insert all HDD SSD modules see section Installing 2 5 inch HDD SSD modules on page 120 I Make sure that you reinstall the HDD SSD module in the bay it was located before the HDD backplane replacement Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 ...

Page 138: ... 47 7 2 10 2 Removing the defective SAS expander board Ê Remove the SAS expander board as described in section Removing the SAS expander board on page 132 7 2 10 3 Installing the new SAS expander board Ê Install the SAS expander board as described in section Installing the SAS expander board on page 135 7 2 10 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on pag...

Page 139: ...t a few centimeters see section Removing 2 5 inch HDD SSD modules on page 122 I The HDD SSD modules need not to be removed But if you want to remove them nevertheless check if all HDD SSD modules are uniquely identified so that you can reinsert them into their original bays 7 2 11 2 Installing the second HDD backplane Ê Install the second HDD backplane as described in section Right side 4 x 2 5 in...

Page 140: ...hown in the figure above 7 2 11 3 Installing additional HDD SSD modules Ê Remove the dummy locks as described in section Removing a 2 5 inch HDD SSD dummy module on page 120 Ê Move the HDD SSD modules installed in the former HDD bays 1 to 4 see figure 48 to the new HDD bays 1 to 4 see figure 50 Ê Insert additional HDD SSD modules as described in section Installing 2 5 inch HDD SSD modules on page ...

Page 141: ...fferent capacities install the biggest capacity first Installing different rotating speed install the fastest rotating speed first Mounting order Figure 76 Mounting order with up to four 3 5 inch HDDs HDD naming scheme Figure 77 Naming scheme with up to four 3 5 inch HDDs I The HDD numbering as listed in the ServerView RAID Manager differs from the HDD mounting order Position Logical drive number ...

Page 142: ...igurations on page 141 7 3 2 2 Removing a 3 5 inch HDD dummy module Figure 78 Removing a 3 5 inch dummy module Ê Press both tabs together 1 and pull the dummy module out of its bay 2 V CAUTION Save the dummy module for future use Always replace dummy modules into unused HDD bays to comply with applicable EMC regulations and satisfy cooling requirements Customer Replaceable Unit CRU Hardware 5 minu...

Page 143: ...HDD module locking lever Ê Pinch the green locking clip 1 and open the locking lever 2 Figure 80 Installing the 3 5 inch HDD module Ê Insert the HDD module into a drive bay and carefully push back as far as it will go 1 Ê Close the locking lever to lock the hard disk drive in place 2 7 3 2 4 Concluding steps Ê Performing a RAID array rebuild on page 85 ...

Page 144: ...eleting a RAID array For further information please refer to the ServerView Suite RAID Management user guide Customer Replaceable Unit CRU Hardware 5 minutes Tools tool less RAID level Procedure RAID 0 Only remove an HDD module combined in a RAID 0 array if defective V CAUTION Removing an operational HDD module will result in data loss RAID 1 RAID 5 Removing an HDD module from a RAID 1 or RAID 5 a...

Page 145: ...AID controller to recognize that an HDD module has been removed and for the hard disk drive to come to a stop Ê Pull the HDD module completely out of its bay 7 3 3 3 Installing a 3 5 inch dummy module V CAUTION If the removed HDD module is not replaced immediately always replace a dummy module into the unused HDD bay to comply with applicable EMC regulations and satisfy cooling requirements Figure...

Page 146: ...ID level 1 1E 10 5 50 6 or 60 An HDD module can only be replaced during operation in conjunction with a corresponding RAID configuration All HDD modules drives must be uniquely identified so that they can be reinstalled in their original bays later If this is not done existing data can be lost 7 3 4 1 Preliminary steps Ê Locating the defective server on page 43 Ê Locating the defective component o...

Page 147: ...e 7 3 5 1 Preliminary steps Ê Locating the defective server on page 43 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Release all HDD modules and pull them out a few centimeters see section Removing a 3 5 inch HDD module on page 145 I The HDD modules need not to be removed But if you want to remove them neve...

Page 148: ...s disengage see circles Ê Take out the HDD backplane 7 3 5 3 Installing the new 3 5 inch HDD backplane Figure 83 Installing the 3 5 inch HDD backplane Ê Position the HDD backplane on the three hooks see circles Ê Push the HDD backplane downward Make sure that the lower cant of the HDD backplane fits in the guides A V CAUTION Ensure that none of the cables are strained or damaged ...

Page 149: ...ug P6 to connector SGPIO 3 power cable to connector PWR 7 OOB cable to connector SMBus if applicable For the cable plan see section Cabling on page 285 7 3 5 4 Concluding steps Ê Insert all HDD modules see section Installing a 3 5 inch HDD module on page 143 I Make sure that you reinstall the HDD module in the bay it was located before the HDD backplane replacement Ê Reassembling on page 52 Ê Conn...

Page 150: ...150 Upgrade and Maintenance Manual RX1330 M1 Hard disk drives solid state drives ...

Page 151: ...he metallic areas or the edges of the circuit boards If devices are installed or disassembled using methods other than those outlined in this chapter the warranty will be invalidated The installation indicated on this note is sometimes changed to the kind of possible options without notice For further safety information please refer to chapter Important information on page 31 8 1 Basic information...

Page 152: ...ng a defective fan module 8 2 1 Preliminary steps Ê Locating the defective server on page 43 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Locating the defective component on page 45 Field Replaceable Unit FRU Hardware 10 minutes Tools tool less ...

Page 153: ...6 Disconnecting the fan cable Ê Disconnect the fan cable of the fan module from the system board Ê Lift off the fan module upward about 2 cm To do this press up the four rubber pins A Figure 87 Removing the fan module Ê Push the fan cable through the opening of the fan cage Ê Take out the fan module ...

Page 154: ...alling the fan module Ê Thread the fan cable through the opening of the fan cage see close up and insert the fan module Notice the direction of the fan label see circle Figure 89 Connecting the fan cable Ê Press down the four rubber pins until they engage A Ê Connect the fan cable to the system board ...

Page 155: ...intenance Manual 155 Fans 8 2 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 Ê Performing a fan test after replacing a defective fan on page 89 ...

Page 156: ...156 Upgrade and Maintenance Manual RX1330 M1 Fans ...

Page 157: ...ving internal options Circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity Always discharge static build up e g by touching a grounded object before handling electrostatic sensitive devices ESDs Do not touch the circuitry on boards or soldered parts Hold circuit boards by their metallic areas or edges If devices are installed or disassembled us...

Page 158: ...tion Slot 1 Riser module 1 PCIe G3 x8 x8 wired Low profile slot maximum length 175 mm dedicated slot for modular RAID controller Slot 2 Riser module 2 PCIe G2 x8 x4 wired Low profile slot maximum length 175 mm Slot 3 Riser module 3 PCIe G3 x8 x8 wired Low profile slot maximum length 175 mm Fan2 Fan3 Fan4 Fan5 P30 PWR1 PWR2 Frontpanel Intel C226 Riser card x4 Riser card x8 CPU Indicate CSS Battery ...

Page 159: ...ujitsu Technology Solutions PSAS CP400i S26361 F3842 E2 L502 1 1 2 1 E 5 4 8 3 F 1 6 3 6 2 S e 0 0 4 P C S A S P c i g o L I S L 1 2 1 1 EMULEX FC CTRL LPe12002 S26361 F3961 E2 S26361 F3961 E202 S26361 F3961 L2 S26361 F3961 L202 1 1 2 2 EMULEX FC CTRL LPe1250 S26361 F3961 E1 S26361 F3961 E201 S26361 F3961 L1 S26361 F3961 L201 1 1 2 3 Qlogic FC CTRL QLE2560 S26361 F3631 E1 S26361 F3631 L1 S26361 F3...

Page 160: ...the latest information of the installing order refer to your server s hardware configurator available online at the following address for the EMEA market http ts fujitsu com products standard_servers index htm for the Japanese market http jp fujitsu com platform server primergy system ...

Page 161: ...n LSI MegaRAID Figure 92 Perforated and non perforated slot brackets Installing the slot bracket Ê Place the controller on the mounting tabs on the slot bracket Ê Fasten the slot bracket to the controller with two M3 x 4 5 mm screws Upgrade and Repair Unit URU Hardware 5 minutes Tools Phillips PH2 No 2 screw driver 1 Full height bracket non perforated 2 Full height bracket perforated 3 Low profile...

Page 162: ...abs on the slot bracket 1 Ê Carefully shift the slot bracket towards the controller until the plug shells engage with the cut outs in the slot bracket connector panel 2 Ê Ensure that the ESD springs on the plug shells properly engage with the slot bracket as shown see circles Figure 94 Fastening the slot bracket D2755 Ê Fasten the slot bracket to the controller with two M3 x 4 5 mm screws ...

Page 163: ...Figure 95 Assembled network adapter D2755 9 2 2 Removing a slot bracket 9 2 2 1 Removing the slot bracket Ê Remove the two screws Ê Remove the controller from the mounting tabs on the slot bracket Upgrade and Repair Unit URU Hardware 5 minutes Tools Phillips PH2 No 2 screw driver ...

Page 164: ...odules Preparing the SFP transceiver module Figure 96 Removing the protective optical port plug Ê Remove the SFP transceiver module from its protective packaging Ê Remove the optical port plug from the new additional SFP transceiver module V CAUTION Always keep the protective port plugs attached to the transceiver optical bores and fiber optic cable connectors until you are ready to make a connect...

Page 165: ...tch and fold down the locking bail on the SFP transceiver module Inserting the SFP transceiver module Figure 98 Inserting the SFP transceiver module Ê Insert and slide the SFP transceiver module into the socket connector as far as it will go I If only one slot is equipped with a SFP transceiver module use the left connector as shown ...

Page 166: ...e 99 Latching the locking bail Ê Carefully fold up and latch the locking bail Figure 100 Installing the protective optical port plug Ê If the SFP transceiver module is not immediately connected to an LC connector attach the protective optical port plug to the transceiver optical bores ...

Page 167: ...y SFP transceiver module Ê If applicable install the secondary SFP transceiver module accordingly 9 3 2 Removing an SFP transceiver module For Fiber Channel over Ethernet FCoE configurations the ethernet server adapter is equipped with one or two SFP small form factor pluggable transceiver modules Upgrade and Repair Unit URU Hardware 5 minutes Tools tool less ...

Page 168: ... port plug Ê If present remove the protective optical port plug from the SFP transceiver module V CAUTION Save the protective port plug for future use Figure 103 Unlatching the locking bail Ê Carefully unlatch and fold down the locking bail on the SFP transceiver module to eject the transceiver from the socket connector ...

Page 169: ...Figure 104 Removing the SFP transceiver module Ê Pull the SFP transceiver module out of its socket connector Ê Attach the protective optical port plug to the transceiver optical bores I Place the removed SFP transceiver module in an antistatic bag or other protective environment ...

Page 170: ...functionality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Remove the corresponding riser module as described in section Removing a riser module on page 58 9 4 1 2 Removing the slot cover Figure 105 Removing the slot cover example riser module 1 Ê Remove the slot cover Upgrade and Repair Unit UR...

Page 171: ...scribed in section Installing a slot bracket on page 161 Figure 106 Installing an expansion card example riser module 1 Ê Carefully press the expansion card into the riser card slot A until it clicks into place 1 Make sure that the lug on the slot cover B clicks into place in the corresponding hole 2 9 4 1 4 Concluding steps Ê Install the corresponding riser module as described in section Installi...

Page 172: ... Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Remove the corresponding riser module as described in section Removing a riser module on page 58 9 4 2 2 Removing the expansion card Ê If necessary disconnect the cables from the expansion card Figure 107 Removing the expansion card example riser module 1 Ê Pull out the expansion card from the riser ...

Page 173: ...he slot cover Make sure that the lug on the slot cover A clicks into place in the corresponding hole 9 4 2 4 Concluding steps Ê Install the corresponding riser module as described in section Installing a riser module on page 60 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 ...

Page 174: ...defective server on page 43 Ê If applicable ensure to note down your current network settings in the operating system Ê Disabling SVOM boot watchdog functionality on page 64 Ê Suspending BitLocker functionality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Locating the defective component on page...

Page 175: ...ents in the system BIOS on page 79 Ê Updating RAID controller firmware on page 74 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 Ê After replacing a network controller in a server running Linux OS Updating the NIC configuration file in a Linux environment on page 83 Ê If applicable reconfigure your network s...

Page 176: ... component on page 47 Ê Locating the defective component on page 45 Ê Remove the corresponding riser module as described in section Handling riser modules on page 58 9 4 4 2 Removing the defective riser card Ê Remove the expansion card as described in section Removing the expansion card on page 172 Figure 109 Removing the riser card example riser module 1 Ê Remove the two screws 1 Ê Remove the ris...

Page 177: ...he riser card 1 Ê Fasten the riser card with two screws 2 Ê Install the expansion card as described in section Installing the expansion card on page 171 9 4 4 4 Concluding steps Ê Install the corresponding riser module as described in section Handling riser modules on page 58 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 ...

Page 178: ...45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Locating the defective component on page 45 9 4 5 2 Removing the defective TFM Ê Remove the depending expansion card as described in section Removing the expansion card on page 172 RAID controller TFM kit PRAID EP400i S26361 D3216 Axx TFM 4G LSZ 03 25444 05 PRAID EP420i S26361 D3216 Bxx TFM 8G LS...

Page 179: ... RAID controller D3216 Figure 111 Disconnecting the FBU adapter cable from the TFM Ê Disconnect the FBU adapter cable from the TFM Figure 112 Removing the TFM Ê Remove the two screws 1 Ê Remove the TFM 2 I Note for replacing the TFM The two spacer bolts can remain on the RAID controller ...

Page 180: ... Manual RX1330 M1 Expansion cards and backup units 9 4 5 3 Installing the new TFM Example RAID controller D3216 Figure 113 Installing the TFM A Ê If no TFM has been installed before fit the two spacer bolts on the RAID controller ...

Page 181: ...ith the two screws from the TFM kit Figure 115 Connecting the FBU adapter cable Ê Connect the FBU adapter cable to the TFM Ê Install the expansion card as described in section Installing the expansion card on page 171 9 4 5 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 ...

Page 182: ...utting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Remove the riser module 2 and the riser module 3 as described in section Handling riser modules on page 58 Upgrade and Repair Unit URU Hardware 10 minutes Tools Phillips PH2 No 2 screw driver 1 Full height riser module 2 Extension bracket 3 Screw ...

Page 183: ...dule support 2 Ê Remove the riser card from riser module 3 as described in section Removing the defective riser card on page 176 Figure 118 Installing the riser card example full height riser module Ê Insert the riser card 1 Ê Fasten the riser card with two screws 2 Ê If applicable install a full height slot bracket to the expansion card as described in section Installing a slot bracket on page 16...

Page 184: ...Installing the expansion card example full height riser module Ê Install the expansion card as described in section Installing the expansion card on page 171 Figure 120 Installing the extension bracket Ê Fasten the extension bracket with one screw to the full height riser module see circle ...

Page 185: ...n cards and backup units Figure 121 Installing the full height riser module Ê Insert the riser card into the system board slot and press down the green touch points see circles V CAUTION Make sure that the EMC springs make contact correctly see close ups ...

Page 186: ... The BBU FBU backs up the memory contents of the RAID controller in the event of a power failure You can install one BBU FBU 9 5 1 Installing a BBU 9 5 1 1 Preliminary steps Ê Disabling SVOM boot watchdog functionality on page 64 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Upgrade and Repair Unit URU Hardwa...

Page 187: ...eparing the BBU V CAUTION Do not connect the cable using excessive force the connector is weak Figure 122 Connecting the BBU cable Ê Connect the BBU cable to the BBU V CAUTION Make sure that the connector side with the three dots is on the top see close up Otherwise you risk short circuits ...

Page 188: ...nce Manual RX1330 M1 Expansion cards and backup units Figure 123 Installing the BBU in the holder Ê At a slight angle fit the BBU under the right retaining bracket on the holder 1 Ê Fold down the BBU until it locks in place 2 ...

Page 189: ...older Ê Insert the holder into the chassis so that the three shoulder screw caps on the chassis floor rest in the wide ends of the keyhole slots on the holder Ê Slide the holder in direction of the arrow The shoulder screw caps on the chassis floor will lock in the narrow ends of the keyhole slots on the holder Ê Ensure that the locking handle on the holder properly snaps in place see circle ...

Page 190: ...n Installing an expansion card on page 170 Figure 126 Connecting the BBU cable to the RAID controller Ê Connect the BBU cable to the RAID controller V CAUTION Make sure that the connector side with the three dots is on the top Otherwise you risk short circuits Do not connect the cable using excessive force the connector is weak ...

Page 191: ...n page 78 Ê Switching on the server on page 57 Note on BBU charging and calibration The BBU may be deeply discharged due to extended storage time and wrongly show as bad or defective in the ServerView RAID Manager In this case the BBU will automatically enter a trickle charge cycle for recovery This initial charge may take up to 12 hours before the BBU will initiate a recalibration cycle Ê Enter t...

Page 192: ...ion process manually using the ServerView RAID Manager I If this procedure still does not fix the BBU status please contact your local Fujitsu customer service partner 9 5 2 Installing an FBU 9 5 2 1 Preliminary steps Ê Disabling SVOM boot watchdog functionality on page 64 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component o...

Page 193: ...eparing the FBU Figure 128 Installing the FBU in the holder A Ê At a slight angle fit the FBU under both retaining brackets of the holder Ê Push in the FBU until it locks in place Figure 129 Installing the FBU in the holder B Ê Ensure that the FBU is properly seated in the holder as shown ...

Page 194: ...3 Installing the FBU Ê Install the FBU with the holder as described in section Installing the BBU on page 189 Ê If applicable install the TFM as described in section Installing the new TFM on page 180 Ê Connect the FBU adapter cable to the TFM as described in section Installing the new TFM on page 180 Ê Install the RAID controller with the TFM as described in section Installing an expansion card o...

Page 195: ... the FBU cable Ê Route the FBU cable as shown in the figure 9 5 2 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Updating RAID controller firmware on page 74 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Switching on the server on page 57 ...

Page 196: ...t on page 47 9 5 3 2 Removing the BBU with the holder Figure 132 Removing the BBU with the holder Ê Lift up the green locking handle on the holder see circle while sliding the holder in direction of the arrow as far as it will go I After that the shoulder screw caps on the chassis floor will rest in the wide ends of the keyhole slots on the holder Ê Lift the holder out of the chassis Upgrade and R...

Page 197: ...e holder Ê Fold up the BBU 1 and at a slight angle remove it from the holder 2 9 5 3 4 Disconnecting the BBU cable from the BBU Figure 134 Disconnecting the BBU cable from the BBU Ê Disconnect the BBU cable from the BBU 9 5 3 5 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 ...

Page 198: ...sposed of in accordance with local regulations concerning special waste 9 5 4 1 Preliminary steps Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 9 5 4 2 Removing the FBU with the holder Ê Remove the FBU with the holder as described in section Removing the BBU with the holder on page 196 Upgrade and Repair Unit...

Page 199: ...s 9 5 4 3 Disconnecting the FBU cable from the FBU Figure 135 Disconnecting the FBU cable from the FBU Ê Disconnect the FBU cable from the FBU 9 5 4 4 Removing the FBU from the holder Figure 136 Removing the FBU from the holder Ê Pull the FBU at a slight angle out of the holder ...

Page 200: ...waste 9 5 5 1 Preliminary steps Ê Disabling SVOM boot watchdog functionality on page 64 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 9 5 5 2 Removing the defective BBU Ê Remove the BBU with the holder as described in section Removing the BBU with the holder on page 196 Ê Remove the BBU from the holder as des...

Page 201: ...ue to extended storage time and wrongly show as bad or defective in the ServerView RAID Manager In this case the BBU will automatically enter a trickle charge cycle for recovery This initial charge may take up to 12 hours before the BBU will initiate a recalibration cycle Ê Enter the ServerView RAID Manager and check the current BBU status I For further information please refer to the ServerView S...

Page 202: ...s to the component on page 47 9 5 6 2 Removing the defective FBU Ê Remove the FBU with the holder as described in section Removing the FBU with the holder on page 198 Ê Disconnect the FBU cable from the FBU as described in section Disconnecting the FBU cable from the FBU on page 199 Ê Remove the FBU from the holder as described in section Removing the FBU from the holder on page 199 9 5 6 3 Instal...

Page 203: ...rds and backup units 9 5 6 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Updating RAID controller firmware on page 74 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Switching on the server on page 57 ...

Page 204: ...204 Upgrade and Maintenance Manual RX1330 M1 Expansion cards and backup units ...

Page 205: ...ol down before installing or removing memory modules to prevent burns Do not insert and remove memory modules repeatedly Doing so may cause failures If the memory module has not been correctly inserted it may cause a fire Insert the memory module with attention to its direction Pressing out the securing clips on the memory module connector will eject the installed memory module To prevent damage a...

Page 206: ...tm for the Japanese market http jp fujitsu com platform server primergy system Technology DDR3 1600 unbuffered single rank SR or dual rank DR UDIMM memory modules with ECC Support for up to 4 UDIMM memory modules Total memory size up to 32 GB Configuration per channel Max speed DIMM 2 DIMM 1 1 DDR3 1600 empty SR DR 2 DDR3 1600 SR DR SR DR Front VGA SMB4 SATA5 iRMC S4 Riser card x4 Indicate CSS TPM...

Page 207: ...memory slot 1 channel A DIMM 1A first Within all channels memory slot 1 must be populated prior to slot 2 Install memory modules within a channel in descending order of capacity higher capacity in slot 1 lower capacity in slot 2 Channel A B Slot ID 2A 1A 2B 1B DIMM 1 1 2 1 2 3 3 1 2 4 3 1 4 2 Table 4 Mounting order ...

Page 208: ...from one channel to the other If the amount of memory differs between the two channels the system board will run in dual channel asymmetric mode Regardless of the mode all DIMMs will run at the highest common frequency that is allowed by the SPD Data of the DIMMs and the max speed of the selected configuration Single channel mode is used when 1 memory module is populated in DIMM 1A channel A B D u...

Page 209: ...n page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 10 2 2 Selecting the memory slot Ê Choose the memory slot according to the configuration rules in Basic information on page 206 10 2 3 Installing a memory module Figure 139 Opening the securing clips Ê Press the securing clips on both sides of the memory slot concerned outward Upgrade and Re...

Page 210: ...ins on page 55 Ê Updating or recovering the system board BIOS and iRMC on page 71 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 10 3 Removing a memory module 10 3 1 Preliminary steps Ê Suspending BitLocker functionality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mai...

Page 211: ...y module out of the slot 2 10 3 3 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 10 4 Replacing a memory module 10 4 1 Preliminary steps Ê Locating the defective server on page 43 Ê Disabling SVOM boot watchdog functionality on page 64 Upgrade and Repair Unit URU Hardware ...

Page 212: ...ection Removing a memory module on page 211 10 4 3 Installing the new memory module Ê Install the memory module as described in section Installing a memory module on page 209 10 4 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Updating or recovering the system board BIOS and iRMC on page 71 Ê Enabling replaced components in the system BIOS on page 79...

Page 213: ...up e g by touching a grounded object before handling electrostatic sensitive devices ESDs Do not touch the circuitry on boards or soldered parts Hold circuit boards by their metallic areas or edges When removing or installing the processor be careful not to touch or bend the spring contacts on the processor socket Never touch the underside of the processor Even minor soiling such as grease from th...

Page 214: ... fujitsu com products standard_servers index htm for the Japanese market http jp fujitsu com platform server primergy system 11 2 Replacing the processor V CAUTION Processors are modules which are extremely sensitive to electrostatic discharges and therefore must always be handled with care After a processor has been removed from its protective sleeve or from its socket place it with its smooth si...

Page 215: ...t on page 47 Ê Removing a riser module on page 58 11 2 2 Removing the heat sink Figure 142 Removing the heat sink Ê Loosen the four screws of the heat sink in a crossover pattern according to the numbering Ê Carefully turn the heat sink back and forth to detach it from the processor I This may be necessary due to the adhesive quality of the thermal paste located between the heat sink and the proce...

Page 216: ...the surface of the processor Ê Clean the underside of the heat sink and the surface of the processor using a lint free cloth 11 2 3 Removing the defective processor Figure 143 Opening the lever Ê Press down the lever 1 and unhook it Ê Open the lever 2 Figure 144 Opening the holder Ê Take the holder by the small grip 1 and open it 2 ...

Page 217: ...processor socket V CAUTION Be careful not to touch or bend the spring contacts on the processor socket 11 2 4 Installing the new processor Ê Remove the protective cap from the bottom side of the processor Figure 146 Installing the processor Ê Insert the new processor carefully into the processor socket Notice the coding see circles ...

Page 218: ...ecause soldering pads may be damaged Ê Press the lever slowly downward 2 until it is hooked in again 3 11 2 5 Applying the thermal paste to the processor surface I For the Japanese market the service engineer must follow the instruction provided separately If the processor replacement kit contains a new heat sink a thin layer of thermal compound has already been pre applied to its lower surface In...

Page 219: ...ompound syringe FTS FSP P304000004 contains thermal paste for three processors Figure 149 Applying the thermal paste Ê Apply a small point shaped amount of thermal paste 1 0 gram see description above to the center of the processor surface as shown V CAUTION Do not mix different types of thermal paste ...

Page 220: ...value doesn t apply to the Japanese market Notice the position of the air flow label 11 2 7 Concluding steps Ê Installing a riser module on page 60 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 I If the Global Error LED is flashing with the error message CPU has been changed on the display after the system is powered on please follow the steps below Ê Restart the system...

Page 221: ...7 Ê Resuming BitLocker functionality on page 84 11 3 Replacing the heat sink 11 3 1 Preliminary steps Ê Locating the defective server on page 43 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Removing a riser module on page 58 11 3 2 Removing the defective heat sink Ê Remove the heat sink as described in sec...

Page 222: ...e heat sink V CAUTION Do not touch the thermal paste on the underside of the heat sink Ê Install the heat sink as described in section Installing the heat sink on page 220 11 3 4 Concluding steps Ê Installing a riser module on page 60 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 ...

Page 223: ...t touch the circuitry on boards and soldered parts Hold the metallic areas or the edge of the circuit boards The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity Before handling them first touch a metal part on the server to discharge static electricity from your body Before installing an internal accessible drive see the manual for the acc...

Page 224: ... 2 5 inch or 3 5 inch HDD configuration The proceeding for installing removing is identic except the routing of the cables and the depending ODD power connector on the system board see section Onboard connectors on page 300 3 5 inch HDD configuration Figure 151 Position of the ODD bay example 3 5 inch HDD configuration Figure 152 Routing ODD cables example 3 5 inch HDD configuration ...

Page 225: ...grade and Maintenance Manual 225 Optical disk drive 2 5 inch HDD configuration Figure 153 Position of the ODD bay example 2 5 inch HDD configuration Figure 154 Routing ODD cables example 2 5 inch HDD configuration ...

Page 226: ...g the ODD latch Depending on chassis variants the ODD latch can be stored in different ways ODD latch and two screws in a package fastened with two screws to the chassis of the fan bridge Figure 155 Example ODD latch in a package Figure 156 Example ODD latch on fan bridge ...

Page 227: ...s to the component on page 47 12 2 2 Removing the dummy cover Figure 157 Removing the dummy cover Ê Pull the dummy cover out of the bay V CAUTION Keep the dummy cover for future use If you remove the accessible drive again and do not replace it with a new one the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures Upgrade ...

Page 228: ...age see figure 155 or Ê Remove the two screws and take the ODD latch from the fan bridge see figure 156 Figure 158 Installing the ODD latch on the ODD Ê Fasten the ODD latch with two screws to the rear side of the ODD Figure 159 Installing the ODD Ê Push the ODD into the bay 1 simultaneously pressing the front of the ODD slightly down until the ODD latch engages 2 ...

Page 229: ...nect the ODD power cable 1 to the ODD Ê Connect the SATA cable 2 to the ODD I The ODD power cable and the SATA cable are preinstalled 12 2 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 ...

Page 230: ...ocker functionality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 12 3 2 Removing the ODD Figure 161 Disconnecting the cables from the ODD Ê Disconnect the ODD power cable and the SATA cable from the ODD Field Replaceable Unit FRU Hardware 5 minutes Tools Torx Plus 6 screw driver ...

Page 231: ...f the arrow until it disengages 1 Ê Pull the ODD out of the bay 2 Figure 163 Removing the ODD latch from the ODD Ê Remove the two screws see circles Ê Remove the ODD latch Ê If no new ODD will be installed Ê Store the ODD latch in a package see figure 155 or Ê Fasten the ODD latch with two screws to the fan bridge see figure 156 ...

Page 232: ...dummy cover Ê Push the dummy cover inward until it engages at the right side 12 3 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 Ê Verifying and configuring the backup software solution on page 76 ...

Page 233: ...e mains on page 46 Ê Getting access to the component on page 47 12 4 2 Removing the defective ODD Ê Remove the ODD as described in section Removing the ODD on page 230 12 4 3 Installing the new ODD Ê Install the ODD as described in section Installing the ODD on page 228 12 4 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on pa...

Page 234: ...234 Upgrade and Maintenance Manual RX1330 M1 Optical disk drive ...

Page 235: ...ter replacing the front panel it is necessary to program the ChassisID prom of the front panel Beside the CPU temperature sensor and housing temperature sensor provided on the system board an ambient temperature sensor is also included on the front panel In case of a defective ambient temperature sensor please replace the front panel Front panel module The front panel module consists of a holder a...

Page 236: ...cing the system board the backup data is restored from the Chassis ID board to the new system board V CAUTION For that reason the front panel and system board must not be replaced simultaneously In this case restoring the system configuration data on the system board would fail 13 2 1 1 Preliminary steps Ê Locating the defective server on page 43 Ê Disabling SVOM boot watchdog functionality on pag...

Page 237: ... 2 Removing the front panel module Figure 165 Disconnecting the cables A Ê Disconnect the front panel cable 1 and the front USB cable 2 from the system board Figure 166 Disconnecting the cables B Ê If applicable disconnect the front VGA cable from the system board ...

Page 238: ...its bay 2 until the holder is completely accessible Figure 168 Removing cables from the front panel module Ê Disconnect the front panel cable 1 Ê Remove the two corresponding screws and disconnect the front USB cable 2 Ê If applicable disconnect the front VGA cable 3 I If the VGA cable is secured with a cable tie open the cable tie Please do not cut the cable tie ...

Page 239: ... front VGA board with the front VGA connector as described in section Installing the front VGA board on page 242 Figure 169 Connecting cables to the front panel module Ê Connect the front panel cable 1 Ê Push the front USB connector in the corresponding recess and fasten the front USB cable with two screws 2 Ê If applicable connect the front VGA cable to the front VGA board 3 I If the VGA cable wa...

Page 240: ... Push the front panel module in its bay 1 Ê Fasten the front panel module with two screws 2 Figure 171 Connecting the cables A Ê Connect the front panel cable 1 and the front USB cable 2 to the system board Figure 172 Connecting the cables B Ê If applicable connect the front VGA cable to the system board ...

Page 241: ...e server on page 57 Ê Verifying system information backup restore on page 73 Ê Resuming BitLocker functionality on page 84 13 3 Front VGA board 13 3 1 Installing the front VGA board 13 3 1 1 Preliminary steps Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Removing the front panel module on page 237 Upgrade a...

Page 242: ...GA board again and do not replace it with a new one the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures 13 3 1 3 Installing the front VGA board Figure 174 Installing the front VGA board Ê Push the front VGA connector in the corresponding recess 1 and fasten the front VGA board with two screws 2 Ê Route the cable tie un...

Page 243: ...he mains on page 55 Ê Switching on the server on page 57 13 3 2 Removing the front VGA board 13 3 2 1 Preliminary steps Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Removing the front panel module on page 237 Upgrade and Repair Unit URU Hardware 10 minutes Tools Phillips PH1 No 1 screw driver ...

Page 244: ...ed with a cable tie pull out the cable tie 1 Ê Remove the two screws 2 and remove the front VGA board 3 13 3 2 3 Installing the dummy cover Ê Install the dummy cover see figure 173 13 3 2 4 Concluding steps Ê Installing the front panel module on page 239 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 ...

Page 245: ... 3 3 2 Removing the defective front VGA board Ê Remove the front VGA board as described in section Removing the front VGA board on page 244 13 3 3 3 Installing the new front VGA board Ê Install the front VGA board as described in section Installing the front VGA board on page 242 13 3 3 4 Concluding steps Ê Installing the front panel module on page 239 Ê Reassembling on page 52 Ê Connecting the se...

Page 246: ...PROM After replacing the system board the backup data is restored from the Chassis ID board to the new system board V CAUTION For that reason the front panel and system board must not be replaced simultaneously In this case restoring the system configuration data on the system board would fail 13 4 1 1 Preliminary steps Ê Locating the defective server on page 43 Ê Disabling SVOM boot watchdog func...

Page 247: ...I The front panel on QRL and the front panel cable are combined in one spare part Figure 176 Disconnecting the front panel cable Ê Pull up the locking bar 1 Ê Remove the front panel cable 2 Figure 177 Disconnecting the front panel cable B Ê Thread the front panel cable through the opening see circle ...

Page 248: ...nce Manual RX1330 M1 Front panel Figure 178 Removing the front panel on QRL A Ê Remove the two screws see circles Figure 179 Removing the front panel on QRL B Ê Remove the front panel Ê Pull the front cable out of the opening ...

Page 249: ... 1 3 Installing the front panel on QRL Figure 180 Installing the front panel A Ê Thread the front panel cable through the opening Figure 181 Installing the front panel B Ê Position the front panel on the ear Ê Fasten the front panel with two screws see figure 178 ...

Page 250: ...ront panel cable 2 Please make sure that the front panel cable is assembled as shown blue marking Ê Press down the locking bar 3 13 4 1 4 Concluding steps Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Enabling SVOM boot watchdog functionality on page 78 Ê Using the Chassis ID Prom Tool on page 87 Ê Switching on the server on page 57 Ê Verifying system information back...

Page 251: ...edges For further information please refer to chapter Important information on page 31 14 1 Basic information This section provides instructions for the system board and the following components CMOS memory volatile BIOS memory and the real time clock are powered by a lithium coin cell CMOS battery This cell lasts up to ten years depending on ambient temperature and use If the CMOS battery is depl...

Page 252: ...hildren Do not throw batteries into the trash can Lithium batteries must be disposed of in accordance with local regulations concerning special waste For further safety information please refer to section Environmental protection in the operating manual of your server Ensure to insert the CMOS battery with the positive pole facing up 14 2 1 1 Preliminary steps Ê Locating the defective server on pa...

Page 253: ...em board components in case of slipping If the CMOS battery cannot be ejected without the help of a tool it is recommended to use a tooth pick Ê Insert a new CMOS battery of the same type into the socket 3 and 4 14 2 1 3 Concluding steps Ê Dispose of the CMOS battery in accordance with local regulations concerning special waste Ê Reassembling on page 52 Ê Connecting the server to the mains on page...

Page 254: ...ality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Remove the riser module 3 as described in section Removing a riser module on page 58 14 3 1 2 Installing the UFM Figure 184 UFM installation kit Field Replaceable Unit FRU Hardware 5 minutes Software 5 minutes Tools tool less 1 USB Flash Module ...

Page 255: ... Ê Connect the UFM to the system board The UFM spacer must click into the hole on the system board 14 3 1 3 Concluding steps Ê Install the riser module 3 as described in section Installing a riser module on page 60 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Enabling SVOM boot watchdog functionality on page 78 ...

Page 256: ...e the drive tray Ê The server should now boot from the Recovery Tool CD Ê Follow the on screen instructions 14 3 2 Removing the UFM 14 3 2 1 Preliminary steps Ê Disabling SVOM boot watchdog functionality on page 64 Ê Suspending BitLocker functionality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê...

Page 257: ...nual 257 System board and components 14 3 2 2 Removing the UFM Figure 187 Removing the UFM Ê Remove the nylon screw of the UFM 1 Ê Disconnect and remove the UFM 2 The UFM spacer remains on the system board Figure 188 Remaining UFM spacer ...

Page 258: ... the customer you break it according to the following procedure and dispose it Figure 189 Tools for breaking the UFM Figure 190 UFM breaking method Ê Use a long nose pliers and a combination pliers to break the UFM in half as shown in the figure 14 3 2 3 Concluding steps Ê Install the riser module 3 as described in section Installing a riser module on page 60 Ê Reassembling on page 52 Ê Connecting...

Page 259: ...tionality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Remove the riser module 3 as described in section Removing a riser module on page 58 14 3 3 2 Removing the defective UFM Ê Remove the UFM as described in section Removing the UFM on page 257 Ê The UFM spacer remains on the system board Field...

Page 260: ... nylon screw from the UFM 1 Ê Remove the UFM spacer 2 Figure 192 Installing the UFM Ê Connect the UFM to the system board and the remaining UFM spacer 1 Ê Fasten the UFM to the UFM spacer with the nylon screw 2 14 3 3 4 Concluding steps Ê Install the riser module 3 as described in section Installing a riser module on page 60 Ê Reassembling on page 52 0 ...

Page 261: ... the server Ê Right after switching on the server insert the Recovery Tool CD into the DVD drive and close the drive tray Ê The server should now boot from the Recovery Tool CD Ê Follow the on screen instructions 14 4 Trusted Platform Module TPM 14 4 1 Installing the TPM 14 4 1 1 Preliminary steps Ê Suspending BitLocker functionality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting...

Page 262: ...iser module 1 as described in section Removing a riser module on page 58 14 4 1 2 Installing the TPM Figure 193 TPM installation kit Figure 194 Position on the system board 1 TPM Trusted Platform Module 3 Special screw for TPM 2 TPM spacer I The black TPM spacer is not used in this server 4 TPM bit insert for TPM special screw 0 1 2 ...

Page 263: ... board and components Figure 195 Inserting the TPM spacer on the system board Ê Insert the TPM spacer into the hole on the system board Figure 196 TPM bit insert Ê Attach the TPM bit insert or TPM module fixing tool Japanese market to a bit screw driver ...

Page 264: ...ng steps Ê Install the riser module 1 as described in section Installing a riser module on page 60 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 Ê Enable TPM in the system board BIOS Proceed as follows Ê Switch on or restart your server Ê As soon as the startup screen appears press the F2...

Page 265: ...f the contact persons DO NOT have a backup copy available inform them that removing the TPM will cause to lose all data 14 4 2 1 Preliminary steps Before removing the TPM board perform the following steps Ê Before removing the TPM board it is necessary to remove BitLocker protection from the computer and to decrypt the volume Ask the system administrator to turn off BitLocker protection using the ...

Page 266: ...itLocker drive encryption please refer to the Microsoft Knowledge Base Fujitsu service partners will find additional information also available in Japanese on the Fujitsu Extranet web pages Ê Disable TPM in the system board BIOS Proceed as follows Ê Switch on or restart your server Ê As soon as the startup screen appears press the F2 function key to enter the BIOS Ê Select the Advanced menu Ê Sele...

Page 267: ... Ê Carefully loosen the TPM screw using a thin slotted screw driver e g watchmaker s screw driver or the dedicated TPM screw driver Japanese market 2 V CAUTION Ensure to turn the screw clockwise in order to remove it Slowly and carefully increase the pressure on the screw until it begins to turn The effort when loosing the screw should be as low as possible Otherwise the thin metal bar may break r...

Page 268: ...ether the hooks on the TPM spacer 1 see close up and remove it from the system board 2 I If the TPM is to be replaced the TPM spacer may remain on the system board 14 4 2 3 Concluding steps Ê Installing the new system board on page 280 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 ...

Page 269: ...TPM board will cause to lose all data 14 4 3 1 Preliminary steps Ê Locating the defective server on page 43 Ê Suspending BitLocker functionality on page 63 Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Removing the defective system board on page 279 Field Replaceable Unit FRU Hardware 30 minutes Tools Remov...

Page 270: ...er is already present on the system board Ê Install the TPM as described in section Installing the TPM on page 262 14 4 3 4 Concluding steps Ê Reinstall the system board as described in section Installing the new system board on page 280 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 Ê Resuming BitLocker functionality on page 84 I You...

Page 271: ... web frontend For further information please refer to the ServerView embedded Lifecycle Management eLCM user guide 14 5 1 Installing the iRMC microSD card 14 5 1 1 Preliminary steps Ê Shutting down the server on page 45 Ê Disconnecting the server from the mains on page 46 Ê Getting access to the component on page 47 Ê Remove the riser module 1 as described in section Removing a riser module on pag...

Page 272: ...ard slot 1 until it locks in place 2 I The onboard position of the microSD card slot can be found in section Connectors and indicators on the system board on page 300 14 5 1 3 Concluding steps Ê Install the riser module 1 as described in section Installing a riser module on page 60 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 ...

Page 273: ...e 46 Ê Getting access to the component on page 47 Ê Remove the riser module 1 as described in section Removing a riser module on page 58 14 5 2 2 Removing the iRMC microSD card Figure 202 Removing the iRMC microSD card Ê To eject the iRMC microSD card gently push it in and then let go 1 Ê Pull the iRMC microSD card straight out of its slot 2 Upgrade and Repair Unit URU Hardware 5 minutes Tools a p...

Page 274: ...Concluding steps Ê Install the riser module 1 as described in section Installing a riser module on page 60 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 14 5 3 Replacing the iRMC microSD card 14 5 3 1 Preliminary steps Ê Locating the defective server on page 43 Ê Shutting down the server on page 45 Ê Disconnecting the server from the...

Page 275: ...on Removing the iRMC microSD card on page 273 Ê Install the new iRMC microSD card as described in section Installing the iRMC microSD card on page 271 14 5 3 3 Concluding steps Ê Install the riser module 1 as described in section Installing a riser module on page 60 Ê Reassembling on page 52 Ê Connecting the server to the mains on page 55 Ê Switching on the server on page 57 ...

Page 276: ...e system board and connected to the new system board For a detailed description please refer to section Replacing the TPM on page 269 The TPM is activated in the system BIOS Field Replaceable Unit FRU Hardware 40 minutes Software 20 minutes Tools Replacing the system board Phillips PH2 No 2 screw driver Magnifying glass for inspecting processor socket springs recommended Replacing the TPM Bit scre...

Page 277: ...ains system information like server name and model housing type serial number and manufacturing data To avoid the loss of non default settings when replacing the system board a backup copy of important system configuration data is automatically stored from the system board NVRAM to the Chassis ID EPROM After replacing the system board the backup data is restored from the Chassis ID board to the ne...

Page 278: ...note on the installation slot number for each memory module Make sure that you reinstall the memory modules in the slot they were located before the replacement Ê Remove the heat sink see section Removing the heat sink on page 215 Ê Remove all expansion cards see section Expansion cards and riser cards on page 170 I Before removing the expansion cards take a note on the installation slot number fo...

Page 279: ...Maintenance Manual 279 System board and components 14 6 1 2 Removing the defective system board Ê Disconnect all cables from the system board Figure 203 Position of the screws Ê Remove the eight screws from the system board ...

Page 280: ...ystem board come under tension and increase the risk of damage and malfunction Don t damage the EMI springs which are essential to comply with applicable EMC regulations and satisfy cooling requirements and fire protection measures Ê Place the removed and the new system board on an antistatic surface Ê Remove the TPM as described in section Removing the TPM on page 265 14 6 1 3 Installing the new ...

Page 281: ... probably have to be scrapped Ê Install the processor on the new system board as described in section Installing the new processor on page 217 Ê Reconnect all cables to the system board Two power cables of power supply Fan cables Front panel cable Front USB cable Power cable for HDD backplane SATA cable s for HDD backplane SATA cable for ODD if applicable Power cable for ODD if applicable Front VG...

Page 282: ... not restored automatically please change the settings manually using the information collected during preliminary steps If you couldn t determine the BIOS version ask the customer to reconfigure all BIOS settings and password Ê Verifying the system time settings on page 80 Ê Looking up changed MAC WWN addresses on page 85 Ê Updating the NIC configuration file in a Linux environment on page 83 Ê E...

Page 283: ...h HDD backplane C9 T26139 Y4041 V1 CBL_PDB_POWER System board to power distribution board C10 T26139 Y3956 V3 CBL_PDB_SIDEBAND System board to power distribution board C11 T26139 Y4040 V2 CBL 4HDD SAS 2 5 RAID card to 4x 2 5 inch HDD backplane C12 T26139 Y4040 V3 CBL 4HDD SAS 2 5 RAID card to 4x 2 5 inch HDD backplane L shape C13 T26139 Y3959 V351 CBL_HDD_3 5_POWER From System board to 3 5 inch HD...

Page 284: ... C19 T26139 Y4040 V15 CBL_4HDD_DATA3 5 Cougar4 to 3 5 inch HDD backplane C20 T26139 Y4040 V20 CBL_SAS3 0_385 Cougar4 to 4x 2 5 inch HDD backplane rectangular Expander C21 T26139 Y4031 V103 CBL FBU03 700 Cougar4 to FBU No Part number Description From to ...

Page 285: ... standard power supply PSU E614 V70 P W R C T R L P W R D3229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR PWR4 HDD PWR SMBus DVD opt SAS BP A3C40157818 4 x 3 5 Frontpanel 2x USB Front USB Front VGA optional C1 Data PWR P1 P2 P3 P4 C13 PWR SMBus C6 C7 C3 C5 C4 C8 SGPIO ...

Page 286: ...P W R C T R L P W R D3229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR PWR4 HDD PWR SMBus DVD opt SAS BP A3C40157818 4 x 3 5 Frontpanel 2x USB Front USB Front VGA optional C1 Data PWR P1 SAS Controller 1 MLC1 oller 1 MLC2 iBBU FBU P2 P3 P4 C8 C17 PWR SMBus C10 C7 C3 C5 C4 C13 C9 C6 SGPIO ...

Page 287: ...andard power supply PSU E614 V70 P W R C T R L P W R D3229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR PWR3 HDD PWR SMBus DVD opt SAS BP A3C40157852 L shape 4 x 2 5 Frontpanel 2x USB Front USB Front VGA optional C1 Data PWR X5 C2 PWR SMBus C6 C7 C3 C5 C4 C12 ...

Page 288: ... E575 P W R C T R L P W R D3229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR PWR3 HDD PWR SMBus DVD opt Frontpanel 2x USB Front USB Front VGA optional C1 Data PWR SAS Controller 1 MLC1 oller 1 MLC2 iBBU BBU C12 C16 C10 C7 C3 C5 C4 C2 C9 C6 SAS BP A3C40157852 L shape 4 x 2 5 X5 PWR SMBus ...

Page 289: ...W R D3229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR PWR3 HDD PWR SMBus DVD opt Frontpanel 2x USB Front USB Front VGA optional C1 Data PWR SAS Controller 1 MLC1 oller 1 MLC2 iBBU FBU C12 C17 C10 C7 C3 C5 C4 C2 C9 C6 SAS BP A3C40157852 L shape 4 x 2 5 X5 PWR SMBus SAS BP A3C40157828 4 x 2 5 X5 PWR SMBus C11 ...

Page 290: ...dundant power supply SAS BP A3C40170040 10 x 2 5 10 x 2 5 PWR D3229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR HDD PWR SMBus Frontpanel 1x USB Front USB C15 RAID Controller 1 MLC1 oller 1 MLC2 iBBU FBU C11 C17 C14 Expander C11 PSU E575 P W R C T R L P W R C10 C9 ...

Page 291: ...7818 4 x 3 5 P1 P2 P3 P4 PWR SMBus SGPIO PSU E575 P W R C T R L P W R D3229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR HDD PWR SMBus DVD opt Frontpanel 2x USB Front USB Front VGA optional C1 Data PWR SAS Controller 1 Cougar IV ugar IV ll 1 MLC1 e r IV r IV MLC2 FBU FBU C19 C21 C10 C7 C3 C5 C4 C13 C9 ...

Page 292: ...P W R C T R L P W R D3229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR HDD PWR SMBus DVD opt Frontpanel 2x USB Front USB Front VGA optional C1 Data PWR SAS Controller 1 Cougar IV ugar IV MLC1 ller 1 IV r IV MLC2 FBU FBU C18 C21 C10 C7 C3 C5 C4 C2 C9 SAS BP A3C40157852 L shape 4 x 2 5 X5 PWR SMBus ...

Page 293: ...229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR HDD PWR SMBus DVD opt Frontpanel 2x USB Front USB Front VGA optional C1 Data PWR SAS Controller 1 Cougar IV ugar IV MLC1 ller 1 IV r IV MLC2 FBU FBU C18 C21 C10 C7 C3 C5 C4 C2 C9 SAS BP A3C40157852 L shape 4 x 2 5 X5 PWR SMBus SAS BP A3C40157828 4 x 2 5 X5 PWR SMBus C20 ...

Page 294: ...er supply Cougar 4 SAS BP A3C40170040 10 x 2 5 10 x 2 5 PWR D3229 SATA HDD P W R C T R L P W R Frontpanel Front USB Front VGA ODD Data ODD PWR HDD PWR SMBus Frontpanel 1x USB Front USB C15 RAID Controller 1 MLC1 oller 1 MLC2 FBU FBU C20 C21 C14 Expander C20 PSU E575 P W R C T R L P W R C10 C9 Cougar IV ...

Page 295: ...gure 215 Front side 2 5 inch HDDs up to 4 HDDs Figure 216 Front side 2 5 inch HDDs up to 8 HDDs Figure 217 Front side 2 5 inch HDDs up to 10 HDDs Pos Component 1 ID card 2 Front VGA option dummy cover 3 Front panel and indicators 4 ODD option dummy cover 5 4x 8x 10x 2 5 inch hard disk drives dummy modules ...

Page 296: ...enance Manual RX1330 M1 Appendix Figure 218 Front side 3 5 inch HDDs Pos Component 1 ODD option dummy cover 2 ID card 3 Front VGA option dummy cover 4 Front panel and indicators 5 4x 3 5 inch hard disk drives dummy modules ...

Page 297: ...ower supply Figure 221 Rear side redundant power supply and full height riser module Pos Component 1 Standard power supply one power supply unit Redundant power supply up to 2 hot plug power supply units dummy cover 2 PCI slot 3 riser module 3 3 PCI slot 2 riser module 2 4 PCI slot 1 riser module 1 5 I O panel 6 PCI slot 3 full height riser module ...

Page 298: ...h HDDs and standard power supply Pos Component 1 Standard power supply one power supply unit 2 Front panel module front VGA option dummy cover 3 Up to 4x 3 5 inch hard disk drives dummy modules 4 ODD option dummy cover 5 4x fan modules 6 Processor 7 Main memory 8 Riser module 1 9 Riser module 2 10 Riser module 3 ...

Page 299: ...r supply Pos Component 1 Redundant power supply up to 2 hot plug power supply units dummy cover 2 Front panel module front VGA option dummy cover 3 ODD option dummy cover 4 Up to 8x 2 5 inch hard disk drives dummy modules 5 5x fan modules 6 Processor 7 Main memory 8 Riser module 1 9 Riser module 2 10 Riser module 3 ...

Page 300: ... board D3229 P30 PWR1 PWR2 Front VGA Frontpanel SMB4 SATA5 Intel C226 iRMC S4 Riser card x4 Riser card x8 CPU Indicate CSS Battery TPM Riser card x8 Shared LAN Standard LAN UFM USB 2 0 USB 2 0 USB 3 0 USB 3 0 Slot3 Slot2 Slot1 Jumper Micro SD MLC SATA1 4 DIMM2A DIMM1A DIMM2B DIMM1B Managem LAN VGA COM1 Intel i210 Service LAN Intel i210 HDD ACTIVITY Front USB FAN4 FAN5 FAN3 FAN2 FAN1 PWR3 PWR4 PC98...

Page 301: ...er supply connector 12V 8 FAN5 Power connector for system fan 5 9 USB FRONT Front USB connector 10 FAN4 Power connector for system fan 4 11 FAN3 Power connector for system fan 3 12 FAN2 Power connector for system fan 2 13 FAN1 Power connector for system fan 1 14 PWR4 Power supply connector for ODD 3 5 inch HDD configuration 15 FRONT VGA Connector for optional front VGA 16 SMB4 OOB Out Of Band conn...

Page 302: ...disconnected it is possible to indicate the faulty component by pressing the indicate CSS button No Description 1 Indicate CSS button P30 PWR1 PWR2 Front VGA Frontpanel SMB4 SATA5 Intel C226 iRMC S4 Riser card x4 Riser card x8 CPU Indicate CSS Battery TPM Riser card x8 Shared LAN Standard LAN UFM USB 2 0 USB 2 0 USB 3 0 USB 3 0 Slot3 Slot2 Slot1 Jumper Micro SD MLC SATA1 4 DIMM2A DIMM1A DIMM2B DIM...

Page 303: ...r a failure may be over temperature measured by one of the sensors sensor is defective CPU error software detected an error C Identification blue on server has been highlighted using iRMC web frontend ServerView Operations Manager or the ID button on the front panel for easy identification blue flashing local monitor off D Memory off memory module running orange on memory module failure E AUX powe...

Page 304: ...or VGA 5 Error indicator orange ID indicator blue description see preceding section 6 Standard LAN connector this connector is displayed in BIOS Setup Utility and MAC address label as LAN1 7 Shared LAN connector for WOL PXE iSCSI function this connector is displayed in BIOS Setup Utility and MAC address label as LAN2 8 Management LAN connector for iRMC S4 server management function Indicator Statu...

Page 305: ...lue flashing local monitor off 2 LAN link transfer indicator green on LAN connection established off no LAN connection green flashing data transfer in progress 3 LAN speed indicator yellow on traffic a transfer rate of 1 Gbit s green on traffic a transfer rate of 100 Mbit s off traffic a transfer rate of 10 Mbit s Indicator Status Description Status indicator green flashing power supply unit opera...

Page 306: ... Indicators on the front panel on QRL I The meaning of the buttons is described in the corresponding operating manual 1 Reset button 2 NMI button 3 ID button ID indicator 4 CSS indicator orange 5 Global Error indicator orange 6 HDD SSD activity indicator 7 On Off button power on indicator 8 Power off indicator AC connected near by the On Off button ...

Page 307: ...or off no critical event non CSS component orange on prefailure detected non CSS component orange flashing indicates a failure of a non CSS component Reasons for a failure may be over temperature measured by one of the sensors sensor is defective CPU error software detected an error 6 HDD SSD activity indicator green on data access in progress 7 Power on indicator off is off in the following case ...

Page 308: ...but connected to the mains AC connected the system has been switched on and is in power on delay I After connecting the server to the mains it takes about 60 seconds until the server enters the standby mode off is off in the following cases the system is not connected to the mains the system is powered on and in normal operation S0 Pos Indicator Status Description 1 Activity indicator off optical ...

Page 309: ...s Description 1 HDD BUSY off HDD inactive green on HDD in active phase drive active drive being accessed 2 HDD FAULT off no HDD error orange on HDD faulty or rebuild stopped drive defective needs replacing a rebuild process was stopped or the HDD module is not correctly inserted orangeslow flashing HDD rebuild the data is being restored after changing a drive ...

Page 310: ...of the following components and cables Print Setting PWD CLR open normal operation default short clear password and apply the default BIOS settings RCVR 1 2 normal operation default 2 3 recovery mode Field Replaceable Units FRU Front VGA SMB4 SATA5 iRMC S4 Indicate CSS TPM Riser card x8 Shared LAN Standard LAN Slot1 Jumper Micro SD MLC SATA1 4 DIMM2B DIMM1B Managem LAN Intel i210 Service LAN Intel...

Page 311: ...an module is not included in the minimum startup configuration the server must be shut down immediately after the diagnostic process is complete POST phase has been passed The minimum startup configuration must be used exclusively for diagnostic purposes by maintenance personnel never in daily operation Component Notes System board no TPM UFM or expansion cards installed CPU with CPU heat sink 1 m...

Page 312: ...312 Upgrade and Maintenance Manual RX1330 M1 Appendix ...

Reviews: