background image

Visit our Website for more information on this product

www.fumeboss.com

984 Farewell St S, Unit #3 Oshawa, ON L1H 6N6

Tel:   (416) 276-9211  |  info@ccmechanical.ca

READ AND SAVE THESE INSTRUCTIONS

Operation & Maintenance Manual

FUME BOSS

Summary of Contents for FB-800-015N1

Page 1: ...bsite for more information on this product www fumeboss com 984 Farewell St S Unit 3 Oshawa ON L1H 6N6 Tel 416 276 9211 info ccmechanical ca READ AND SAVE THESE INSTRUCTIONS Operation Maintenance Manu...

Page 2: ...cklist 7 4 4 Principles of Operation 8 4 5 Failure Event 8 SECTION 5 MAINTENANCE TROUBLESHOOTING 9 5 1 To Maintain this Product Safely 9 5 2 Tools Required 9 5 3 Routine Maintenance Schedule 10 5 4 Se...

Page 3: ...low all applicable ANSI OSHA UL CSA National Local Fire Codes and other regulatory guidelines covering the safe use of equipment that extracts fumes collects dusts and exhausts filtered air either ind...

Page 4: ...explosion protection system If you are unsure if the product you purchased is correct for your application call Fume Boss at 416 276 9211 1 4 Dust Collection Hazards 1 5 Safety Stickers This machine...

Page 5: ...iculated capture arm FB 800 015N1 1 5 1750 1P 60Hz 13 2 800 15 6 5 Model Arm Length ft Arm Diameter in Net Weight lbs Product Dimensions in Width a Height C Length b FUME BOSS with articulated capture...

Page 6: ...ly upon receiving the unit carefully examine the carton for damage during transit 2 Use lift forks or truck to move 3 Remove packing material 4 Avoid tipping or inverting during handling 5 The item se...

Page 7: ...as been followed Before plugging unit in to an input power source look at the manufacturer s label located on the exterior of the unit and ensure the source is correctly sized in terms of Voltage and...

Page 8: ...enough to the worksite to capture all dust and fumes that will be produced Ensuring that all safety procedures have been followed the operator can turn on the machine and begin working When not in use...

Page 9: ...enance on this product Disconnect power before performing any maintenance on unit including filter inspection The input power to this unit is high voltage and touching any live electrical parts can ca...

Page 10: ...4 Detach Rear Panel by first unclasping twist lock latches located on rear of the main body 5 Push the Retention Rod Handle to the forward most position 6 Slide and lock the Locking Bolt in the left...

Page 11: ...k Leads at Input Power Source Air Flow Restricted Check clean Hood inlet Capture tubes Unit Operates Properly Call for Service 416 276 9211 Fume Boss Call for Service 416 276 9211 Fume Boss Call for S...

Page 12: ...d Debris from use Read and understand SECTION 1 Safety Precautions and SECTION 4 Operation before maintenance Do not breathe the dust collected from product while changing cleaning filters or performi...

Page 13: ...n cause fatal shocks or severe burns Do not touch live electrical parts APPENDIX 1A ELECTRICAL DIAGRAM MANUAL ELECTRIC SHOCK HAZARD WARNING Do not route auxiliary contact cable in the same conduit as...

Page 14: ...MODEL N FUME BOSS SERIAL N SERVICE LOCATION CONTROL N 14 APPENDIX 2 MAINTENANCE RECORD Fume Boss authorizes this page to be photocopied or otherwise reproduced as needed for management of maintenance...

Page 15: ...Vent Hood STEP 1 Unpack capture arm hood and base STEP 2 Attach swivel base to mounting plate APPENDIX 3 ARM TO BLOWER DIRECT INSTALLATION 3 1 Unpack capture arm hood and base 3 2 Attach swivel base t...

Page 16: ...ntion Rod Handle 16 Twist and release Twist Lock Latches Open Rear Panel STEP 1 Opening rear panel APPENDIX 4 FILTER INSTALLATION 4 1 Opening rear panel for filter access 4 2 Preparing for filter STEP...

Page 17: ...antity Hardware 1 Fume Boss Assembly 1 Locking Bolt 1 Retention Rod Handle 1 Filter 17 4 3 Inserting filter STEP 3 Insert clean filter 4 4 Locking filter STEP 4 Locking filter Push Retention Rod to fo...

Page 18: ...Quantity Hardware 1 Fume Boss Assembly 1 Rear Panel 2 Twist Lock Latches 18 4 3 Closing rear panel for filter access STEP 5 Closing rear panel Close Rear Panel Twist and release Twist Lock Latches...

Page 19: ...19 APPENDIX 5 EXPLODED VIEW PART NUMBERS...

Page 20: ...STOP BRACKET 1 9 FB_LATCH BRACKET INV CAB FUMEBOSS BT GB LATCH BRACKET 1 10 FB_CAM LOCK INV CAB FUMEBOSS BT GB CAM LOCK 1 11 FB_ADAPTER INV CAB FUMEBOSS BT GB MOUNT PLATE 1 12 FB_HANDLE INV CAB FUMEBO...

Page 21: ...TICKERS The machine is marked with a wet filtration safety sticker to remind the operator of safe working practices The machine is marked with safety stickers in appropriate places to remind the opera...

Page 22: ...22 NOTES...

Page 23: ...23 NOTES...

Page 24: ...24 NOTES...

Page 25: ...25 NOTES...

Page 26: ...grated with any products equipment units connections and or systems of a third party Third Party Products we hereby expressly exclude all of the following warranties express or implied namely a warran...

Page 27: ...rder is for a customized product including without limitation any custom engineered product and b an event set forth at Section 5 2 hereof occurs you will be responsible for payment of the entire amou...

Page 28: ...Visit our Website for more information on this product www fumeboss com 984 Farewell St S Unit 3 Oshawa ON L1H 6N6 Email info ccmechanical ca An Absolent Group Company...

Reviews: