SERIES II 16 AMP POWER CONDITIONERS

Summary of Contents for PL-PRO DE II

Page 1: ...SERIES II 16 AMP POWER CONDITIONERS...

Page 2: ...eter displays incoming line voltage 1 5 VAC True RMS Current Meter displays power draw 0 5 amp 1 Furman Series II Features SMP advanced surge protection extreme voltage shutdown ultra low clamping vol...

Page 3: ...y Additionally Furman s trusted over voltage circuitry protects against those all too frequent accidental connections to 380 VAC by shutting off the incoming power until the over voltage condition is...

Page 4: ...to the PowerCon outlets of P models while the unit is switched on 5 Route the power cord and other cables where they are not likely to be walked on tripped over or stressed Pay particular attention to...

Page 5: ...the rack PL PRO SERIES II E PE These models offer a 20 segment LED bar graph meter that displays incoming voltage between 180 and 256 volts in 4 volt steps The normal range voltages are indicated in...

Page 6: ...witch Rear Light Switch Rear Light Switch Rear Light Switch Light Tube Dimmer Light Tube Dimmer Light Tube Dimmer Light Tube Dimmer LED Light Tubes LED Light Tubes Switched Outlet Switched Outlet Swit...

Page 7: ...ether the light tubes are extended or ush with the front panel our high ef ciency full spectrum LEDs generate no appreciable heat All Series II units feature a rear BNC socket which will accept any 12...

Page 8: ...ive or resistive NOTE Your Series II Power Conditioner does not compensate for high or low line voltage If you frequently move your rack to different locations derive power from generators use long ex...

Page 9: ...em and change the AC source if necessary TROUBLE SHOOTING GUIDE 1 Symptom No power to the AC outlets Possible Cause Circuit breaker switch has tripped to the off position due to excessive load Action...

Page 10: ...urces Because noise occurs at higher frequencies than the 50 or 60 Hz AC line it can be effectively reduced by low pass lters THREE YEAR LIMITED WARRANTY Furman Sound Inc having its principal place of...

Page 11: ...ve Product in the manner and for the period provided above Manufacturer shall not have any other obligation with respect to the Products or any part thereof whether based on contract tort strict liabi...

Page 12: ...PRO E II PE II 4 VAC calibrated with internal trimpot adjustments PL PRO DE II PDE II PM PRO E II PE II 1 5 VAC Current Meter Accuracy PM PRO E II PE II 0 5 amp Spike Protection Modes Line to neutral...