   FURMAN

   FURMAN

   FURMAN

   FURMAN

PRO SERIES

Power Conditioner/Monitor

MODELS PM-PRO, PM-PRO-E

Owner's Manual

3-9844

© 1998 FURMAN SOUND, INC.

960112-1407

Summary of Contents for PM-PRO

Page 1: ...FURMAN FURMAN FURMAN FURMAN PRO SERIES Power Conditioner Monitor MODELS PM PRO PM PRO E Owner s Manual 3 9844 1998 FURMAN SOUND INC 960112 1407...

Page 2: ...TVSS rating 400V peak L N 680V peak L G N G 1 nanosecond 11 000 amps 8 x 20mS pulse 550 joules total Differential mode Greater than 40 dB Common mode greater than 60 dB both 1 to 200 MHz 1 75 4 45 cm...

Page 3: ...uctions for future reference 2 The PM PRO should not be used near water for example near a bathtub washbowl kitchen sink laundry tub in a wet basement near a swimming pool etc 3 The PM PRO should be s...

Page 4: ...ified service personnel when a The power supply cord or the plug has been frayed kinked or cut b Objects have fallen or liquid has spilled into the unit c The PM PRO has been exposed to rain or other...

Page 5: ...on can safely absorb and dissipate large spikes from nearby light ning strikes and other sources up to 11 000 amps across any wiring mode hot neutral hot ground or neutral ground as well as highly att...

Page 6: ...220V where 120V is expected The PM PRO senses voltages that are so high or low that operation would be impossible and shuts the power down before damage can occur For the PM PRO the cutoff voltages a...

Page 7: ...e power from generators use long extension cords travel internationally or are in an area prone to brownouts you may benefit from the use of one of Furman s AC Line Voltage Regulators LED AMMETER This...

Page 8: ...lowing chart summarizes how the PM PRO s voltmeter responds to input voltages from extremely low to extremely high AC VOLTS 90 100 110 120 128 Mains Below 80V 80 90 90 104 106 108 110 120 122 124 126...

Page 9: ...the actual building where the PM PRO is installed or somewhere very nearby some damage may be unavoid able due to the extremely high voltage and current present If this does occur most likely damage w...

Page 10: ...rization from Furman Furman s liability under this warranty is limited to repair or replace ment of the defective unit Furman will not be responsible for incidental or consequential damages result ing...

Page 11: ...PM PRO POWER CONDITIONER MONITOR 11...

Page 12: ...Voltage Regulator 30A 220 230 240V AC Line Voltage Regulator 30A 24 230 220V N America Use AC Line Voltage Regulator 30A 120V Worldwide Use On Line Uninterruptible Power Supply 1KVA Power Distro 100A...