background image

Extractor hood
AW 280790/280720

Gaggenau Operating and installation instruction

Summary of Contents for AW 280720

Page 1: ...Extractor hood AW 280790 280720 Gaggenau Operating and installation instruction...

Page 2: ...m settings b Always turn hood on when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pa...

Page 3: ...ng procedure 8 Intensive setting 9 Special functions 9 Filters and maintenance 10 Grease filters 10 Saturation indicator F 10 Activated carbon filter 11 Cleaning and care 12 Replacing the light bulbsn...

Page 4: ...cal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee...

Page 5: ...racted particularly well at the front of the cooking field The Coanda effect may allow you to operate the extractor hood at a lower quieter level than you were previously accustomed to The Coanda air...

Page 6: ...ging elements out of the reach of children Thoroughly clean the appliance before using it for the first time Before operating the appliance for the first time check that the mains connection is in pro...

Page 7: ...njury to the user Do not place any heavy objects on the appliance Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate...

Page 8: ...ight Fan follow on Intensive setting The most effective method of removing vapours produced during cooking is to Switch the ventilator ON as soon as you begin cooking Switch the ventilator OFF a few m...

Page 9: ...l running time to 3 5 or 10 minutes by simultaneously pressing the Int key and the 1 2 or 3 key and you can store this setting When delivered the appliance is set to five minutes i e the combination o...

Page 10: ...has not started to flash Cleaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dishwasher It is h...

Page 11: ...moving and inserting the metal mesh grease filters 2 Insert the activated carbon filter 3 Insert the metal grease filters see Removing and inserting the metal grease filters Replacing the activated ca...

Page 12: ...sk of fire and ensures that the extractor hood continues operating at maximum efficiency Clean the operating buttons with a mild soapy solution and a soft damp cloth only Do not use stainless steel cl...

Page 13: ...a risk of being burnt 2 Remove the metal mesh filters see Removing and inserting the metal mesh grease filters 3 Loosen the screws for the mounting rails 4 Carefully remove the glass panes 5 Remove t...

Page 14: ...9 Tighten the screws for the mounting rails 10 Insert the metal grease filters see Removing and inserting the metal grease filters 11 Restore the power by inserting the mains plug or switching on the...

Page 15: ...haust air shaft or directly into the open through the outside wall It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to t...

Page 16: ...The extractor hood must not be installed over a solid fuel cooker a potential fire hazard e g flying sparks unless the cooker features a closed non removable cover and all national regulations are obs...

Page 17: ...coal fired heaters continuous flow heaters hot water boilers care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion Safe operatio...

Page 18: ...es We recommend Internal diameter 6 Flat ducts must have an internal cross section that equates to that of round pipes There should be no sharp bends l 6 approx 177 cm2 If pipes have different diamete...

Page 19: ...ly be connected to an earthed socket that has been installed according to relevant regulations If possible site the earthed socket directly behind the chimney panelling The earthed socket should be co...

Page 20: ...w the outline of the area where the hood will be attached Ensure that the minimum distance between the hob and the extractor hood is maintained 30 for an electric hob and 30 for a gas hob The bottom e...

Page 21: ...ove the extractor hood Drill the 4 lower 5 16 fixing holes and press in the wall plugs flush with the wall 8 Attach the extractor hood and screw into position with the remaining 4 screws 9 Stick prote...

Page 22: ...nsert the upper flue duct into the lower flue duct Protect the cover panels from scratches for example by laying the template used for marking the wall over the top edge of the lower section 14 Insert...

Page 23: ...23 KF001 010...

Page 24: ...nau 5551 McFadden Avenue Huntington Beach CA 92649 Telephone 877 4GAGGENAU USA www gaggenau usa com Gaggenau Hausger te GmbH Carl Wery Stra e 34 81739 M nchen Germany www gaggenau com 9000384457 EB 88...