background image

                                                         

 

 

 

1

 / 

12

 

 
 
 
 
 
 
 
 

Magnetic &Portable GPS tracker with Installation in Seconds 

GT3012 

 

           

Summary of Contents for GT3012

Page 1: ...1 12 Magnetic Portable GPS tracker with Installation in Seconds GT3012...

Page 2: ...THE MASTER CONTROLLER 6 6 3 EMERGENCY TAKEOVER FUNCTION 7 6 4 CHANGING THE PASSWORD 7 7 MOTION DETECTED ALERT 7 7 1 VIBRATION SENSITIVITY 7 7 2 SMS OR CALL ALERT SETTINGS 7 8 SMS LOCATION QUERY 8 8 1...

Page 3: ...3 12 16 COMMAND SETTING LIST 11...

Page 4: ...0mAh rechargeable Lithium Ion battery can wait for a month in a true sleeping standby for motion or vibration to wake it into pre programmed periodic location reporting when it starts moving Key Featu...

Page 5: ...s must be less than 3 seconds each in all uses This control button is at the middle top of the device a On Press power button 5 times Both blue and green indicating light will be on for 30 seconds b O...

Page 6: ...ur master controller no is 55 12345678910 Then your login account would be 005512345678910 Default Password 123456 6 Operation Commands Guide 6 1 Set APN VERY IMPORTANT AND MUST BE DONE 1ST For the de...

Page 7: ...stem Since certain applications are more sensitive to external vibration sources the sensor has variable sensitivity settings The unit comes from the factory pre set to 1 on a scale of 1 5 with 1 bein...

Page 8: ...ion through cell phone browser It is suitable for smart phone user only Note Device will start positioning once it is powered on location data will be saved and retained in memory every minute automat...

Page 9: ...ck of 30 60 by controlling sampling frequency and data upload interval The device can be set to collect location data regularly and uploaded to server at appointed interval Initiate the start of inter...

Page 10: ...t exits the geofence will be immediately texted to the master controller as a GeoFence Exit Alert 11 2 Disable the Geofence SMS fenceoff Device Response The Geofence is disabled It should be noted tha...

Page 11: ...efault setting is 1 Alert Setting callalert Call alert will call master number 2 times when motion is detected after 3 minutes non movement smsalert SMS notification will sent to master number when mo...

Page 12: ...ion GeoFence Setting fence 1 99 1 99 represents 01 99km radius bubble around the device fenceoff End Geofence function Status query status Check system status Multi Controller multiquery Enable multi...

Reviews: