background image

Part Number: 3E2453 R1  |  

1   

Installation Note  |  Gallagher T10 Mifare Reader

Installation Note

Gallagher T10 Mifare Reader

 

The Gallagher T10 Mifare Reader

The Gallagher T10 Mifare reader is a smart card proximity reader.  It can 
be installed as either an entry reader or exit reader.

The reader can read Mifare DESFire EV1, Mifare Plus and Mifare Classic 
cards.

The reader sends information to the Cardax FT Controller and acts upon 
information sent from the Cardax FT Controller.  The reader itself does not 
make any access decisions.

The Gallagher T10 Mifare reader uses the “Cardax IV Reader” 
communications protocol to communicate with the Cardax FT Controller.

This equipment contains components that can be damaged by 
electrostatic discharge.  Ensure both you and the equipment are 
earthed before beginning any servicing.

Summary of Contents for T10

Page 1: ...SFire EV1 Mifare Plus and Mifare Classic cards The reader sends information to the Cardax FT Controller and acts upon information sent from the Cardax FT Controller The reader itself does not make any...

Page 2: ...should be linear or a good quality switched mode power supply The performance of the reader may be affected by a low quality noisy power supply Cabling The Gallagher T10 Mifare reader requires a mini...

Page 3: ...al wall check that any reader fixed to the other side of the wall is not less than 200mm 8 inches away Wall thickness less than 200mm 200mm Installation The Gallagher T10 Mifare reader is designed to...

Page 4: ...he reader is flush with and tight against the mounting surface Note Ensure the centre hole allows the cable to run freely out through the mounting surface so that the reader facia can clip into the ba...

Page 5: ...orque of 1 5Nm 1 1 lb ft Fit screw to secure facia to base Facia Building cable Reader tail Connection Removal of the facia assembly is a simple reversal of these steps 7 Connections A Gallagher T10 M...

Page 6: ...x IV Reader 1 Connecting to the Cardax FT GBUS Universal Reader Interface Connect the wires to the sockets as shown in either of the following diagrams RLY 2 COM RLY 2 NO RLY 2 NC DATA 0 DATA 1 OUT 1...

Page 7: ...rs into the Cardax FT Command Centre system The ports to which the Gallagher T10 Mifare reader can connect are set up as groups as follows Two groups numbered 1 and 2 on the Controller 3000 4R and Fou...

Page 8: ...T 2 PB PA Positive Red Negative Black Reserved Orange Reserved Green Reserved Brown CDXIV TX White CDXIV RX Blue Cardax IV Reader Positive Red Negative Black Reserved Orange Reserved Green Reserved Br...

Page 9: ...vironmental regulations for the Restriction of Hazardous Substances in electrical and electronic equipment RoHS The RoHS directive prohibits the use of electronic equipment containing certain hazardou...

Page 10: ...is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the...

Page 11: ...Drill Template 115mm 4 53 inches 35mm 1 38 inches 44mm 1 73 inches 40mm 1 57 inches 13mm 1 2 inch diameter hole for cable 22 5mm 0 89 inches 40mm 1 57 inches...