background image

 

GalvinCare

®

 Mental Health

 

Tapware 

 

PRODUCT CODES: 

 

 

50197 

 

SPECIFICATIONS 

  This products unique design concept eliminates the institutional look and provides anti-ligature 

features and vandal resistant compliance 

  The paddle design handle allows the diverter to be activated with minimal effort. 

  The 170mm round faceplate has a polished stainless steel finish for a homely look and can 

withstand heavy knocks and bevelled edges provide tight fixing 

 

This item is designed for wall installation 

 

IMPORTANT: All GalvinCare

®

 prison taps are tested in accordance with AS/NZS 3718 and leave our premises 

in good working order.

 

 

TECHNICAL DATA 

Inlet

 

½” BSP – Male 

Outlet 

½” BSP – Female 

Headwork 

Diverter Cartridge 

Working Pressure Range (kPa)  

Min 

50 

Max 

500 

Working Temperature Range (°C) 

Min 

Max 

90 

Finish 

Chrome / Polished Stainless Steel 

NOTE: Galvin Specialised continually strive to improve their products.  Specifications may change without 
notice.

 

 

 

PRE-INSTALLATION

 

MOUNTING DETAILS 

– ROUGH IN & OVERALL DIMENSIONS

 

 

Suitable for in-wall mounting 

 

Drill 

6.5mm hole as shown for Anti-Rotation pin. 

 

TOOLS REQUIRED

 

 

Power drill 

Spanner or adjustable crescent

 

Summary of Contents for GalvinCare 50197

Page 1: ...igned for wall installation IMPORTANT All GalvinCare prison taps are tested in accordance with AS NZS 3718 and leave our premises in good working order TECHNICAL DATA Inlet BSP Male Outlet BSP Female Headwork Diverter Cartridge Working Pressure Range kPa Min 50 Max 500 Working Temperature Range C Min 5 Max 90 Finish Chrome Polished Stainless Steel NOTE Galvin Specialised continually strive to impr...

Page 2: ...le for horizontal and vertical mounting It is critical that the centre line of the cartridge spindle is perpendicular to the finished wall to ensure correct fitment of the faceplate and flange 2 Connect water supply Connect water supply to correct inlets as shown ensure a suitable sealing compound is used Connect correct outlet connection to shower outlet Note Water supply should be flushed before...

Page 3: ...t so the body is perpendicular to finshed wall Water flow does not match faceplate markings Handle not aligned correctly to faceplate Remove handle and rotate on the spline until handle matches faceplate Re tighten Outlet on body not connected to the correct service outlet Change outlet connection on body SERVICE AND MAINTENANCE 1 Turn off water Turn off the water supply and turn on the tap handle...

Page 4: ...r download from www galvinengineering com au Galvin Engineering Pty Ltd expressly warrants that the product is free from operational defects in workmanship and materials for the warranty period as shown on the schedule in the manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long ...

Reviews: