background image

 1

SERVICE DEPARTMENT: (724) 746-1100

7610.478.49      6/04

18-2-700  1st Edition

RPD SERIES REFRIGERATED DRYERS

MODELS: RPD25, RPD35, RPD50, RPD75, RPD100

CONTENTS

GENERAL SAFETY INFORMATION ............................ 2
RECEIVING, MOVING, UNPACKING .......................... 2
1.0 INSTALLATION ...................................................3
2.0 OPERATION .......................................................4
3.0 MAINTENANCE .................................................6
SIZING ......................................................................6
ENGINEERING DATA .................................................7
ELECTRICAL SCHEMATICS ........................................ 8
DIMENSIONS / WEIGHTS ..........................................9
TROUBLESHOOTING ...............................................10
PARTS LIST .............................................................11
WARRANTY ............................................................12

INSTRUCTION MANUAL

Internal Use Only

478.39A/040624

Summary of Contents for RPD Series

Page 1: ...RPD35 RPD50 RPD75 RPD100 CONTENTS GENERAL SAFETY INFORMATION 2 RECEIVING MOVING UNPACKING 2 1 0 INSTALLATION 3 2 0 OPERATION 4 3 0 MAINTENANCE 6 SIZING 6 ENGINEERING DATA 7 ELECTRICAL SCHEMATICS 8 DI...

Page 2: ...evidence of loss or damage at time of delivery to you insist that a notation of this loss or damage be made on the delivery receipt by the carrier s agent B UNPACKING Check for Concealed Loss or Dama...

Page 3: ...ded to prevent possible damage from vibration NOTE Outdoor installation Standard units are designed for indoor installation Contact manufacturer if installing outdoors 1 2 Mounting Mount the dryer on...

Page 4: ...d void the warranty 1 5 Moisture separator A Separator and Oil Removal Filter where applicable has an internal drain which automatically discharges collected condensate It may be desirable to pipe the...

Page 5: ...ed in Table 1 2 Where the dryer is consistently operating at less than maximum capacity it may be possible to increase the LED set point to minimize air loss Discretionary adjustments to the dryer sho...

Page 6: ...d drain mechanism annually To facilitate service maintenance kits are available Please refer to page 11 3 0 Maintenance Sizing Determining dryer capacity at actual operating conditions To determine th...

Page 7: ...29 220 183 350 292 Electrical Nominal Voltages 115 1 60 Max Min Voltage 127 104 127 104 127 104 127 104 127 104 Rated Load Amps 3 4 3 9 5 9 7 4 10 3 Locked Rotor Amps 18 0 22 0 28 0 35 0 48 0 Minimum...

Page 8: ...FM R C 1 OL BRN BRN TB 1 L SW L 1 TB 3 1 1 FM 3 L TC1 DRAIN NEUTRAL DRAIN P COMP ON N TB 5 RPD 25 75 115 1 50 60 CUSTOMER CONNECTION POWER CORD IC1 OPTION BOARD SEE OPTION NOTES IC2 OPTION BOARD ADDI...

Page 9: ...8 3 16 18 3 16 20 11 16 20 11 16 H 21 3 16 21 3 16 21 3 16 24 3 16 24 3 16 I 18 1 2 18 1 2 18 1 2 24 24 J 16 1 2 16 1 2 16 1 2 21 13 16 21 13 16 Inlet Outlet Connections 1 2 MPT 1 2 MPT 1 2 MPT 3 4 MP...

Page 10: ...gh air outlet temperature 2 Refrigeration system not func tioning properly resulting in high air outlet temperature 3 Dryer is running with no load a Power failure b Line disconnect switch open c Blow...

Page 11: ...led G4130 120 5 G4130 120 8 G4130 120 9 G4130 121 11 G4130 121 9 G4130 121 9 G4130 122 10 G4130 122 11 G4130 122 15 Compressor Only G4130 108 34 G4130 108 61 G4130 108 35 G4130 108 38 G4130 108 39 G41...

Page 12: ...OR STATU TORY AND IS EXPRESSLY IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE THE MANUFACTURER SHALL NOT BE LIABLE FOR LOSS OR DAMAGE B...

Reviews: