WARNING:
BEFORE PLUGGING IN THE UNIT OR TURNING THE UNIT ON/OFF, BE SURE TO
RESET THE VOLUME CONTROL KNOB TO ITS MINIMUM SETTING. STARTING THE UNIT AT ITS
MAXIMUM SETTING MAY DAMAGE THE FUSE.
The vacuum system aids deep pore cleansing and is also referred to as the suction machine. The suction
removes out deeply embedded dirt, sedum and other impurities. Another benefit is a deep penetrating
massage, drawing blood to the surface of the skin. Note: the vacuum suction does not dislodge blackheads.
Included with this unit should be a pre-assembled complete handle, 6 glass ventricles, and 2 spray bottles.
VACUUM OPERATION
A.
Connect the air tubing with the “yellow” adapter to the “yellow” connector on the machine. Also
connect the
tubing with the “green” adapter to the “green” connector.
B. Select the appropriate ventouse and insert to the yellow adapter (a metal connector w/ a built in
filter).
C. Turn the green power switch to the ON position.
D. Turn the VACUUM ADJUSTMENT KNOB this knob clockwise MAX. (This knob can turn
approximately 1½-2 revolutions).
E. The ventouse control hole should be covered when the ventouse is touching the skin and should be
uncovered when taken off the skin.
F. After the vacuum treatment is complete, use the spray to lightly cover the face with a toner, and pat
dry with cotton pads or a clean towel. This will help remove any debris left on the skin and close the
pores.
SPRAY OPERATION
The spray bottle can be filled with distilled water or toner. The spray bottle is not recommended to be filled
with lotion; lotion is too thick and will cause the blockage of the very fine spray hole in the cap.
A. C
onnect the “green” adapter to the spray bottle.
B. Hold the bottle in an upright position.
C. Place your finger over the small hole at the top of the bottle.
MAINTENANCE
Attachments should be sanitized after each use.
A. Wash glass ventouses and attachments thoroughly with soap and warm water.
B. Soak the glass ventouses in alcohol for 5 minutes allowing them to sterilize.
C. Dry ventouses and store in sterilizer cabinet or autoclave.
PARAGON
®
204 VACUUM & SPRAY
ATTENTION
Recommended for use by professional, state-licensed
estheticians. Operator shall be responsible for and damages to
him/herself, the machine, and/or clients.
Before installing and/or using this unit, please carefully read these
instructions. Be sure to keep this available for later reference.
C A U T I O N
VACUUM TREATMENT TIME VARIES, DIFFERENT SKIN TYPES REQUIRE DIFFERENT
TREATMENTS. PLEASE USE AT YOUR DISCRETION. WHEN THE SKIN IS THIN, DRY,
OR AGING, A LIGHT SUCTION IS RECOMMENDED. FOR OILY SKIN, IT IS
RECOMMENDED THAT THE VACUUM TREATMENT BE PERFORMED AFTER THE
DISINCRUSTATION TREATMENT WITH THE GALVANIC CURRENT.