Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent  
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been 
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation 
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,  
or which has been modified or repaired using unauthorized parts or by unauthorized service agents. 
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.  

The information contained herein, (including design and parts specifications), may be superseded and is subject  

to change without notice.

GARLAND COMMERCIAL INDUSTRIES

185 East South Street

Freeland, Pennsylvania 18224

Phone: (570) 636-1000

Fax: (570) 636-3903

GARLAND COMMERCIAL RANGES, LTD.

1177 Kamato Road, Mississauga, Ontario L4W 1X4

CANADA

Phone: 905-624-0260

Fax: 905-624-5669

Enodis UK LTD.

Swallowfield Way, Hayes, Middlesex UB3 1DQ ENGLAND

Telephone: 081-561-0433

Fax: 081-848-0041

Part # 4520898 (03/31/11)

© 2005 Garland Commercial Industries, Inc.

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE  

OR OTHER FLAMMABLE VAPORS OR  

LIQUIDS IN THE VICINITY OF  

THIS OR ANY OTHER

APPLIANCE

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, 

ALTERATION, SERVICE OR MAINTENANCE 

CAN CAUSE PROPERTY DAMAGE, INJURY, 

OR DEATH. READ THE INSTALLATION,  

OPERATING AND MAINTENANCE  

INSTRUCTIONS THOROUGHLY  

BEFORE INSTALLING OR  

SERVICING THIS EQUIPMENT

INSTALLATION AND  

OPERATION MANUAL

GARLAND RTCS TECHNOLOGY BUILT IN  

INDUCTION COOKERS,  

MODELS: BH/IN 2500, SH/IN 3500,SH/IN 5000,  

SH/WO/IN 3500,SH/WO/IN 5000 & SH/WO/IN 8000 

PLEASE READ ALL SECTIONS OF THIS MANUAL 

AND RETAIN FOR FUTURE REFERENCE.

THIS PRODUCT HAS BEEN CERTIFIED AS  

COMMERCIAL COOKING EQUIPMENT AND 

MUST BE INSTALLED BY PROFESSIONAL  

PERSONNEL AS SPECIFIED. 

INSTALLATION AND ELECTRICAL CONNECTION 

MUST COMPLY WITH CURRENT CODES:

IN CANADA - THE CANADIAN ELECTRICAL 

CODE PART 1 AND / OR LOCAL CODES.

IN USA – THE NATIONAL ELECTRICAL CODE 

ANSI / NFPA – CURRENT EDITION.

ENSURE ELECTRICAL SUPPLY CONFORMS WITH 

ELECTRICAL CHARACTERISTICS SHOWN ON  

THE RATING PLATE.

SA

NITATION

LISTED

CM

86037

C

Summary of Contents for SH/IN 5000

Page 1: ...60 Fax 905 624 5669 Enodis UK LTD Swallowfield Way Hayes Middlesex UB3 1DQ ENGLAND Telephone 081 561 0433 Fax 081 848 0041 Part 4520898 03 31 11 2005 Garland Commercial Industries Inc FOR YOUR SAFETY...

Page 2: ...Part 4520898 03 31 11 Page 2...

Page 3: ...ngerous voltage CAUTION Indicates a hazard or unsafe practice which could result in minor personal injury or property damage Electromagnetic field IMPORTANT INFORMATION Warning Risk of fire or electri...

Page 4: ...Part 4520898 03 31 11 Page 4...

Page 5: ...IN 8000 11 Unit Placement 12 Installation of Operating Unit 12 Fresh Air Intake Installation 13 Instructions For Assembly Induction Built In Units 14 Guidelines For Assembly 14 Mounting Instructions 1...

Page 6: ...ximum Relative Humidity Of Air Storage 10 90 Function 30 90 ELECTRICAL SPECIFICATIONS MODEL VOLTAGE Total KW BH IN2500 208 230 240 2 5 SH IN 3500 208 230 240 3 5 SH IN 5000 208 230 400 440 5 0 SH WO I...

Page 7: ...allowing for efficient cooking and have the following features Simple operation with rotary switch with integrated mains switch Compact module in a frame design with an induction generator controller...

Page 8: ...fresh air by fixing an air duct including shackle or by air openings The air exit must not to be hindered by any obstructions Electrical Supply Please observe the following rules 1 Check and ensure t...

Page 9: ...73mm Side View of the right 0 06 1 5mm air exit air exit 4 06 103mm Ventilator Mains Cable air supply 6 73 171mm 11 02 280mm Ceran surface 10 23 260mm 10 23 260mm 12 20 310mm 12 20 310mm Front view Co...

Page 10: ...3 90 410 x 353mm Side view of the right 0 06 1 5mm Air exit Ventilator Air Supply Air exit 5 63 143mm 12 99 330mm 7 20 183mm Ceran surface 12 60 320mm 12 60 320mm 15 12 384mm 15 12 384mm Front view Ne...

Page 11: ...14 x 13 90 410 x 353mm 11 81 300MM WOK CERAN BOWL Air supply Air exit 0 06 1 5mm 8 46 5mm Side view of the right Front view Net cable Air exit 7 20 183mm 13 47 330mm Ventilator 15 12 384mm 15 12 384m...

Page 12: ...it In order to fix this unit on the surface of the enclosure a cut out for the power switch and the LED must considered The operator control panel has to be fixed vertically on the installation panel...

Page 13: ...nches for dual units for the hot air to escape by installer Failure to provide adequate ventilation for the unit will result in the unit overheating nuisance shut down and potential failure of the uni...

Page 14: ...ake sure that the in coming and outgoing exhaust air do not mix We recommend guaranteeing the supply of fresh air by using a tube with screens vent ducts or Air Intake Kit It is highly recommend that...

Page 15: ...Part 4520898 03 31 11 Page 15 3...

Page 16: ...Part 4520898 03 31 11 Page 16 Figure 4...

Page 17: ...Part 4520898 03 31 11 Page 17 Figure 5...

Page 18: ...Part 4520898 03 31 11 Page 18 Figure 6...

Page 19: ...id injuries burning do not touch this area Use a pan suitable for induction cooking having a bottom diameter of at least 4 72 120mm only BH IN and SH IN 1 Put some water in the pan and place it in the...

Page 20: ...stored Out Of Operation If the cooker is not in use make sure that the control knob is in the OFF position If you don t use the cooker for a long period several days unplug the unit Make sure that no...

Page 21: ...sconnected from the electric connection Don t touch any parts inside the cooker If the supply cord is damaged it must be replaced by the manufacturer the service agent or a similarly qualified person...

Page 22: ...identical to other similar surfaces like glass Do not use corrosive or abrasive cleaning agents such as grill and oven sprays stain and rust removers scouring powder and rough sponges 2 Before being...

Page 23: ...ir inlet temperature must be lower than 104 F 40 C E07 Empty cooking sensing element activated Reset empty cooking protection by switching the unit off E08 Ambient temperature beyond operating range M...

Page 24: ...normal operating conditions 2 Verify that no hot air is sucked in by the fan Reduce the ambient temperature The air inlet temperature must be lower than 104 F 40 C One phase is missing only units with...

Page 25: ...r supplier for repair service 1 To verify if the pan is suitable use a permanent magnet and find out if it sticks on the bottom of the pan If not your pan is not suitable for induction cooking Choose...

Page 26: ...Part 4520898 03 31 11 Page 26...

Page 27: ...Part 4520898 03 31 11 Page 27...

Page 28: ......

Reviews: