background image

 

 

 

INSTRUCTION MANUAL FOR WEATHER STATION 

MODEL  

Precise

 

 

 
 
 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Precise

 
 

Summary of Contents for GARNI610 Precise

Page 1: ...INSTRUCTION MANUAL FOR WEATHER STATION MODEL Precise Precise ...

Page 2: ...its of indoor and outdoor temperature weather forecast icons based on monitoring of changes in barometric pressure option to set a default weather forecast icon absolute relative barometric pressure display display of outdoor heat Index and dew point memory for maximum and minimum measured values of temperature and rel humidity memory for measured values of temperature rel humidity and barometric ...

Page 3: ...imits of the outdoor temperature 5 Indoor temperature and relative humidity alarm upper and lower limits of the indoor temperature Rear side of the main unit 6 Mounting hole 7 Power adapter socket 8 Battery compartment cover 9 Acoustic alarm opening Wireless sensor GARNI 060H 10 TX button 11 Battery compartment cover 12 Battery compartment ...

Page 4: ...Year will flash Use the MEM and CH buttons to set the current year and confirm with SET 7 Month will flash Use the MEM and CH buttons to set the current month and confirm with SET 8 Day will flash Use the MEM and CH buttons to set the current day and confirm with SET 9 The day name shortcut will flash Use the MEM and CH buttons to set the required language CZ Czech EN English DE German IT Italian ...

Page 5: ...lash Now press the TX button in the battery compartment of the wireless sensor Select a different channel for each wireless sensor Once the connection of the main unit to the wireless sensor is established the icon will be displayed permanently Place the main unit and the wireless sensor in the desired location within the range of the wireless sensor signal The connection establishment process mus...

Page 6: ...ioned to ensure good reception of the DCF 77 signal that is outdoors away from potential sources of interference Receiving and adjusting time can take up to 10 minutes MEMORY FOR MAX AND MIN MEASURED VALUES The main unit is equipped with memory for maximum and minimum measured values Press the MEM button repeatedly to display the maximum and minimum measured values of the indoor and outdoor temper...

Page 7: ...ash Use the MEM and CH buttons to set the required temperature The temperature alarm is enabled or disabled by pressing the ALARM button The activation of the alarm is indicated on the display by the icon The upper limit alarm for the indoor temperature can be set from 9 C to 60 C the lower limit from 10 C to 59 C The upper limit alarm for the outdoor temperature can be set from 9 C to 70 C the lo...

Page 8: ...reless sensor away from other electrical equipment the main unit keeps displaying the outdoor temperature and rel humidity even after the wireless sensor is disconnected the main unit displays the last measured data for 30 minutes after disconnection of the wireless sensor the temperature and rel humidity are different when the main unit and the wireless sensor are placed next to each other measur...

Page 9: ...ature measurement range 10 C to 60 C Measurement accuracy 0 2 C 10 C to 50 C Resolution 0 1 C Humidity measurement range 1 to 99 Accuracy of measurement 2 20 to 80 4 1 to 20 80 to 99 Resolution 1 Outdoor HEAT INDEX from 26 C from 40 relative humidity Type of used sensors SENSIRION SHTC3 Dimensions 194 9 x 130 8 x 35 7 mm Wireless sensor GARNI 060H Power supply 2 pcs batteries type AAA 1 5 V micro ...