OWNERS MANUAL
SERIES 72
INDOOR/OUTDOOR WIRE-IN LIGHT CONTROL
FOR INSIDE USE ONLY WITH INCANDESCENT LAMP CIRCUITS OF 500 WATTS OR LESS. NOT FOR USE IN CIRCUITS WITH
FLUORESCENT LAMPS OR WITH LIGHT DIMMERS.
The Wire-in Control can be operated by any Series 50, 51, 52, 53 or Model 73 transmitter.
The Wire-in Control consists of two parts: the power supply and the receiver. It can replace either single pole (1 switch controlling a single light) or 3-
way switches (2 switches controlling a single light). Depending on the 3-way switch wiring, light may turn on after a power failure. If properly wired,
this will not occur with a single pole switch installation.
TURN OFF THE POWER TO CIRCUIT AT FUSE
BOX OR CIRCUIT BREAKER BEFORE BEGIN-
NING INSTALLATION
Figure 1 illustrates the installation of receiver and power supply
to junction box in interior wall.
1. Pry up lower edge of actuator button until it separates from
receiver housing. Set actuator aside.
2. Remove the 6-32"x1-1/2" screw and unplug receiver from power
supply. Set receiver aside.
3. Remove wall plate and set aside for re-assembly.
4. Remove screws holding switch to junction box.
5. Pull switch from the junction box in order to access the connecting
terminals.
On 3-way switches, mark the common terminal wire before
disconnecting. (Common terminal may be marked "common",
"com" - or uses a different color screw (gold or silver) than the
other two terminal screws.)
6. Disconnect wires from switch. Straighten the ends and make sure
that insulation is trimmed back 1/2" to allow connection of power
supply wires.
Transmitter range will vary depending on your house and wiring construction. Metal lath, foil-backed insulation or aluminum siding will
reduce range. After installation is complete, test transmitter operation at various locations within your home for convenience and range.
SINGLE POLE SWITCH: If transmission range Is noticeably shorter when turning light OFF than when turning light ON, reverse wiring
connections.
3-WAY SWITCH: It transmission range Is noticeably shorter when turning light OFF than when turning light ON, the Wire-in Control needs
to be installed in the other switching location. (The black wire in the Wire-in Control must be connected to the "hot" junction box wire.)
CAUTION: If there is a ground on your switch (usually a bare wire attached to a green screw on switch), connect wire to the metal junction
box. If box is plastic, connect wire to metal part of Wire-in Control.
SINGLE POLE SWITCH
3-WAY SWITCH
Fold the BLUE power supply wire back as shown and cap with wire nut.
Screw nut in clockwise direction to secure.
Cap black control wire to one junction box wire and red conrol wire to the
other. Screw wire nuts on clockwise, making sure bare wires are covered.
Start by capping the black control wire to the COMMON "hot or live"
wire; the red and blue control wires separately to the other two junction
box wires in any order. Screw wire nuts on clockwise making sure bare
wires are covered.
_________________________________________________________________________________________________________