Description ATS1151/1156 

ATS2000/3000/4000 ATS1250 

Connection  

Comms 

Comms 

12V

 Power supply 

Power 12V

 12V

 

0V Connection to reader 

GND 0V  0V 

Data + connection to 
reader 

D+ D+ D+ 

Data - connection to 
reader D- 

D- 

D- 

Request to exit button 

IN - - 

Open collector output 
50mA max. 

OUT -  - 

 

3-LED Keypad  

3-LED Keypad with 
Card Reader 

Reader connection to the ATS panels 

 

 

3-LED Keypad / 3-LED Keypad with Card Reader 

M

OUNTING THE UNIT

 

1.  Remove the Allen screw from the reader’s mounting 

plate to open the reader. (Fig. 3) 

2.  Use the mounting plate as a template to mark the screw 

hole locations on the wall. (Fig. 4) 

3.  Run the cable through the rubber gasket (gasket is 

used for outdoors installation) and then through the hole 
in the mounting plate. 

4.  Fasten the mounting plate to the wall.  
5.  Connect the cable  to the terminal block (Fig. 5).  
6.  Set the RAS address DIP switch (Fig. 6). 
7.  Check the jumper position for the heater is ‘ON’ for 

outdoors installation, and ‘OFF’ for indoors (Fig. 5). 

8.  Place the spring on the back tamper switch. (Fig. 4). 
9.  Slide the reader onto the mounting plate and close the 

unit with the Allen screw (reverse order of Fig. 3, and 
then follow Fig. 8). 

C

ONNECTING CONTROL PANEL TO KEYPAD 

(

FIG

. 3) 

Refer  to the ATS control panel installation guide for instructions.  
Each reader has a cover tamper. 

 

Note: Figures and instructions also apply to the 
ATS1151 unless stated otherwise. 

S

AFETY INSTRUCTIONS

 

• 

Always observe the safety regulations applicable in 
your country. Read the following safety instructions 
before attempting to install the product. 

• 

Before disassembling the product, disconnect the 
power supply unit from the controller. 

• 

Only connect the mains to the power supply unit when 
all installation procedures have been completed. 

• 

Never cover the power supply unit as it may overheat. 

• 

When installing, do not force any parts or screws. 

E

XTRA NOTES FOR INSTALLING A KEYPAD OUTDOORS 

(

FIG

. 2) 

1.  Install a rain protection hood over the reader.  

2.  Mount the rubber gasket (supplied) between the unit 

and the wall to seal the unit. 

3.  Set the jumper J4 (Fig. 5) to the ‘ON’ position to enable 

the heater (top two pins). 

4.  If a motorised lock or gate is used, mount the reader a 

few metres away from the door so the lock or gate has 
enough space to open fully. 

C

ABLE ENTRY AND CONNECTIONS 

(

FIG

. 5) 

1.  RAS DIP switches 
2.  Terminal block: +12 V

 

3. Buzzer 
4. Heater 

jumper 

5. Term 

link 

C

ONNECTIONS TERMINALS 

(

FIG

. 5) 

PWR 

Power supply. If the distance between the arming 
station and the control panel does not exceed 
100m, then the arming station can be  

GND  

powered using the Comms + and – from the 
control panel. Otherwise use AUX PWR from 
DGP’s or an auxiliary power supply.  

D+   

Data positive and data negative connection of the 
databus. 

D -   

Remote units can be up to 1.5 km from the ATS 
control panel. 

IN   

A request to exit button (normally open, 
momentary push-button switch) can be connected 
across “IN” and “-“. When pressed, this button 
controls the request to exit function. 

OUT  

Open collector output, 50 mA maximum. It is the 
first output of the output control group that is 
assigned to this arming station.

 

L

INKS 

(

FIG 

5) 

TERM 

Fitted if this device is the last device on the 
system databus. For more details see the ATS 
control panel installation guide. 

 

ATS1151

3-LED Keypad

ATS1156

3-LED Keypad with Card Reader 