ATS1160/1161 Mifare bus reader

Installation instructions

Revision 2.1 (October 2008) 

 Part number 1063986

 

EN

 

 

 

FR

 

 

 

NL

 

 

 

IT

 

 

 

PL

 

 

 

PT

 

 

NO

 

 

ES

 

 

DA

 

 

SV

 

 

 

DE

 

 

 

FI

 

 

 

 

 

 

 

 

 

 

 

www.gesecurity.eu

 

Copyright © 2008 GE Security B.V. All rights reserved 

 

 

 

 

EN

 

Mifare bus reader

The ATS1160/1161 Reader is a Mifare card reader (compatible with 

the GE 

Security cards ACT406/ACT407/ACT408/ACT430). It is 

designed, for example, to mount on metal, window or door frames 

and is suitable for any location that requires a small reader.  
The ATS1161 is equipped with a keypad for Card+PIN applications. 
The ATS1160/1161 incorporates all interface electronics necessary 

to interface with the ATS control panel bus and the ATS 125x local 

bus. 
It is configurable through a Menu system accessible via a bus LCD 

RAS or the ATS1482 Programming card. 
The reader operates from 10.8 to 30 VDC. 
Both the ATS1160 & ATS1161 are waterproof. 

Mounting 

The reader can be mounted on any flat surface by two pan head 

screws, 3.0-3.5 mm diameter, located under the cover. A slightly 

reduced range will be experienced when mounted on metal 

surfaces. 
It is not recommended to use countersunk screws. 
If readers are placed closer than 10 cm from each other or if the 

reader is installed on metal, the reader distance can be shorter. 
Do not install close to sources of powerful electromagnetic 

disturbance. 
Do not cut the cable shorter than 10 cm. 

RAS Addressing 

The address of the reader for bus operations is set to the default 

address RAS 16. You can change it using a configuration card or 

accessing its online menu system when connected to the RS485 

bus. 

 

It is possible to change the reader address with 

configuration card only when the reader is not polled. 

Tamper 

The reader is provided with a tamper facility. When connected to 

the bus, tamper data is transmitted to the Advisor Master with 

system data.  

Reader Menus 

Enter via the Installer menu and select the menu “Remote 

Devices”, then select “RAS”. 
The following options are available: 

1. 

Tamper option: Enable/disable (default enabled). 

2. 

Reader Address: Changing reader address (1-16), 

default = 16. 

Reader Wiring 

Red: 

+12V 

Positive 10.8 to 30 VDC supply, 150 mA 

Black: 

0 Volts 

DC supply ground 

Green: 

D - 

RS485 Data - 

White 

D + 

RS485 Data + 

Spare wires are not used. 
Use WCAT54 cable. Cable length depends on the bus 

configuration. 

Reader LEDs 

 Led 

pos. 

Colour 

Description 

Green System 

disarmed 

Orange System 

armed 

Left 

Green flashing 

Access granted 

Middle 

Orange 

System not ready 

ATS4000 

Right Red 

flashing  Alarm 

Green System 

disarmed 

Red System 

armed 

Green flashing 

Access granted 

Left 

Red flashing 

Access granted during alarm 

Middle Orange 

Always 

on 

ATS125x

 

Right Red 

flashing  Alarm 

 

Technical specifications 

Supply voltage ................................................................................. 10.8 - 30 VDC 
Current consumption .................................................................... 130 mA max. 
Material of design housing .......................................................................Plastic 
Dimensions of housing (H x W x D)................................ 140 x 44 x 20 mm 
Operating temperature ................................................................ -40 to +55 °C 
Storage temperature..................................................................... -40 to +55 °C 
Protection class...................................................................................................IP67 
Cable ............................................................................................................... LIYY 2 m 
Connectivity ...................................................................RS485 data bus device 
Addressing...............................................................Via keypad or config. card 

 

Summary of Contents for ARS1160

Page 1: ...of the reader for bus operations is set to the default address RAS 16 You can change it using a configuration card or accessing its online menu system when connected to the RS485 bus It is possible to change the reader address with configuration card only when the reader is not polled Tamper The reader is provided with a tamper facility When connected to the bus tamper data is transmitted to the A...

Page 2: ... sont disponibles 1 Tamper option dés active l autoprotection activé par défaut 2 Reader Address change l adresse du lecteur 1 16 défaut 16 Câblage du lecteur Rouge 12V Alimentation positive 10 8 à 30 VDC 150 mA Noir 0 Volts Masse d alimentation Vert D RS485 Data Blanc D RS485 Data Les autres fils ne sont pas utilisés Utiliser un câble WCAT54 La longueur de câble dépend de la configuration du bus ...

Page 3: ...MHz RFID Veldsterkte Volgens EN300330 EMC Volgens CE normering Afneembeveiliging Optische sensor IT Mifare lettore di tessere L ATS1160 1161 è un Mifare lettore di tessere compatibile con le tessere GE Security ACT406 ACT407 ACT408 ACT430 Il lettore è stato progettato per esempio per essere installato su superfici metalliche profili di finestre o porte e in tutti i casi dove è necessario in lettor...

Page 4: ...z menu dostępne z poziomu stacji ZAZ z wyświetlaczem lub za pomocą karty konfiguracyjnej ATS1482 Czytnik zasilany jest pod napięciem od 10 8 do 30 VDC Obydwa modele ATS1160 i ATS1161 są wodoszczelne Montaż Czytnik może być zamontowany na dowolnej płaskiej powierzchni za pomocą dwóch wkrętów z płaskimi łbami o średnicy 3 0 3 5 mm które znajdują się pod pokrywą W przypadku montażu na powierzchni met...

Page 5: ... a 10 cm entre eles ou se for instalado sobre metal a distância de leitura pode diminuir Não instale junto a fontes de forte interferência electromagnética Não corte o cabo por forma a ficar com menos que 10 cm Endereçamento do RAS O endereçamento do leitor para operação no bus encontra se de fábrica como RAS 16 Pode alterar utilizando um cartão de configuração ou acedendo ao menu online quando li...

Page 6: ...syning 150mA Sort 0 Volt Minus og jording Grønn D RS485 Data Hvit D RS485 Data Andre kabeler er ikke i bruk Bruk WCAT54 kabel Kabel lengden er avhengig av buss konfigurasjon Leser dioder Led pos Farge Beskrivelse ATS4000 Grønn System frakoblet Oransje System tilkoblet Venstre Blinkende grønn Adgang godkjent Mitten Oransje System ikke klar Høyre Blinkende rød Alarm ATS125x Grønn System frakoblet Rø...

Page 7: ...uración Grado IP IP67 Dimensiones Al x An x F 140 x 44 x 20 mm Conectividad Dispositivo de bus de datos ATS RS485 o Wiegand estándar Carcasa Plástico Información de estado 3 LED Conexión Proporcionado con un cable de 2 m Frecuencia de lectura 13 56 MHz Temperatura de funcionamiento 40 a 55 ºC Temperatura de almacenaje 40 a 55 ºC Campo de emisión Conforme EN300330 EMC Conforme requerimientos CE Tam...

Page 8: ...vå skruvar 3 0 3 5 mm diameter dessa är placerade under fronten En mindre redusering av läsavståndet kan uppstå om läsaren monteras på metallunderlag Försänkta skruvar är en rekomendation Om läsarna monteras närmare än 10cm från varandra eller på metall kan läsavståndet påverkas Montera ej läsaren nära elektromegnetisk strålning Klipp ej kabeln kortare än 10 cm RAS Addressing Adressen på läsaren ä...

Page 9: ...bunden ist auch über ein LCD Bedienteil Die Leseradresse kann mit der Konfigurationskarte nur geändert werden wenn der Leser noch nicht abgefragt wird Sabotage Der Leser verfügt über eine Sabotageeinrichtung Sobald der Leser mit der Zentrale verbunden und abgefragt wird werden auftretende Sabotagedaten mit den Systemdaten an die Zentrale übermittelt Lesermenüs Rufen Sie den Programmiermodus auf un...

Page 10: ...alikko 2 käyttölaite Seuraavat valikot ovat käytettävissä 1 Tamper option Enable disable Kansikytkin käytössä pois käytöstä oletus käytössä 2 Reader Address Lukijan osoite 1 16 oletus 16 Lukijan kytkentä Punainen 12V 10 8 30 VDC syöttö 150 mA Musta 0 Volts DC syöttö miinus Valkoinen D RS485 Data Vihreä D RS485 Data Muut johtimet eivät ole käytössä Käytä WCAT54 kaapelia maksimipituus riippuu väylän...

Page 11: ...ATS1160 1161 Mifare bus reader 11 Installation instructions ...

Page 12: ...12 ATS1160 1161 Mifare bus reader Installation instructions www gesecurity eu ...

Reviews: