background image

 

ATS1340 

Door junction box 

 

 

EN

  

 FI

  

 

DE

  

 IT

 

 

 2006 

GE 

Security 

B.V. 

1056702 

n

 

o

 

J1

J9

J6

J2

J3

J8

J12

FH1

FH2

J4

RL3

RL1

J15

J16

J13

J14

ATS1340

D4

D5

D+

D-

+12V

0V

CWG

CWG

0V

12/24V

OC OUT

SPARE

CW
G

CW
G

0V

+1

2V

D-

D+

0V

(+

)

+

OC

CW
G

CW
G

Zn+

1

Zn

EX

TE

RN

 

TA

M

PE

R

MA

G

N

 S

W

ON

 DO

OR

SW.

 IN

 D

O

O

LOCK

12

/2

4V

 F

O

DO

OR LOCK

+ E

XIT

-B

U

TT

O

N

D+

D-

+12V

0V

OC DOOR REL

EXIT/B.LED

BUZ.

R/B LED

1

2

3

4

5

6

7

8

9

A

B

C

D

ATS1340

A

9 8

B

4

1
2
3

56

 

 

 

EN

ATS1340

Door junction box

What does it do? 

The ATS1340 is designed as a universal door junction box.  
The module has an incoming and outgoing data bus / power connection 
to achieve a proper stub connection for an Advisor MASTER bus reader.  
Onboard relays are provided to connect a door lock and auxiliary outputs 
(i.e. buzzer). For high-energy locks an external 12 V or 24 V power supply 

must be connected. 
Two onboard dual loop resistor inputs configurations are prepared to 
connect a magnetic switch on the door and the switch in the door lock if 
necessary. These connections can be easily hardwired to the nearest 
DGP or panel zones. 
The Advisor MASTER bus reader can be fully wired to the door junction 
box and a request to the exit button easily can be connected as well. For 

more details of the door application please see figure  . 

 

 

 

 

WARNING: 

1. 

Disconnect the mains power before opening the cabinet! 

• 

Disconnect AC mains plug from AC mains wall 

socket, or 

• 

disconnect the mains with the dedicated circuit 
breaker. 

2. 

Disconnect the battery (when applicable). 

Description of ATS1340 and door application 

See figure   and figure  . 

Table 1. Connection description 

Item Description 

1 From 

auxilary 

output 

12 V/24 V ext. power supply 

Databus IN from panel or DGP 

Databus OUT to RAS / DGP 

Auxilary relay output  (RL3)  

Auxilary OC output  

7 Shield 

To Smart Card reader 

9 RTE 

button 

10 

Door lock relay output (RL1)  

11 From 

door 

switches 

12 From 

external 

tamper 

13 

To zone inputs 

Mounting location 

The ATS1340 PCB (see figure  )

 

can be mounted in any Advisor MASTER 

cabinet, which supports the size B board. Preferably the door junction box 
must be mounted in close proximity to a door, which needs access 
control and / or alarm facilities. 

Mounting the unit 

Mounting the ATS1340 door junction box on the wall or ceiling. 

See figure  . 
1. 

Remove the ATS1340 cover. 

2.  Hold the base of the ATS1340 against the mounting surface and 

mark the mounting holes. 

3. 

Drill holes and insert screw anchors, if required. 

 All 

rights 

reserved. 

09/2006 

 www.gesecurity.net 

Summary of Contents for ATS1340

Page 1: ...and a request to the exit button easily can be connected as well For more details of the door application please see figure WARNING 1 Disconnect the mains power before opening the cabinet Disconnect A...

Page 2: ...6 J17 settings N O or N C output Jumper location and label Description 1 1 2 Normaly open output 2 2 3 Normaly closed output 11 Connect the magnetic switch on the door and the optional switch in the d...

Page 3: ...d human health To conform with this directive electrical equipment marked with this symbol must not be disposed of in European public disposal systems European users of electrical equipment must now r...

Page 4: ...ukko 6 J17 asetukset N O tai N C l ht Oikosulkupalan asennot ja merkinn t Kuvaus 1 1 2 Sulkeutuva l ht 2 2 3 Avautuva l ht 11 Oven magneettikosketin ja oven lukkokytkin kytket n J4 liittimeen Taulukko...

Page 5: ...romusta WEEE jonka tarkoitus on minimoida s hk ja elektroniikkalaiteromun ymp rist llisi ja terveydellisi haittoja T ll symbolilla merkittyj elektroniikkalaitteita ei kyseisen direktiivin noudattamise...

Page 6: ...Bus ist kann ein Bus Abschluss durch Einstellen der Steckbr cke auf beide Stifte der Steckkontakte J15 installiert werden standardm ig wird Steckbr cke 15 auf einem Stift platziert 9 Schlie en Sie de...

Page 7: ...tatus der Open Collector Anschl sse kann mit LEDs Tabelle 12 berwacht werden Tabelle 12 Relaisstatus LEDs Bezeichnung Beschreibung 1 RL1 LED D4 zeigt den Status OC T r an J9 4 1 RL3 LED D5 zeigt den S...

Page 8: ...bella 2 Connessioni J1 ingresso bus dati Sequenza connessione e riferimento Descrizione 1 D Dati bus dalla centrale 2 D Dati bus dalla centrale 3 12V 12V dall alimentazione ausiliaria della centrale 4...

Page 9: ...so al J8 user questa stessa alimentazione esterna La connessione protetta da FH2 630 mA Tabella 10 Connessoni J2 alimentazione esterna e ingresso OC Sequenza connessione e riferimento Descrizione 1 0V...

Page 10: ...re conformit a tale direttiva vietato smaltire le apparecchiature elettriche contrassegnate da questo simbolo nei comuni cassonetti per lo smaltimento dei rifiuti siti in territorio europeo Gli utiliz...

Page 11: ...11...

Page 12: ...12...

Reviews: