background image

28”

34-3/8”

39-2/5”

5.8

3.6

Listed by 

Underwriters 

Laboratories

Dimensions and Installation Information (in inches) 

Exhaust Options: 4-way via rear, right, left and bottom.
Circuit Requirements: An individual, properly grounded 
branch circuit, protected by a 30-amp circuit breaker or 
a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36” 
of service cord entry and accessible when dryer is 
mounted in position.
Installation Information: For complete information, see 
installation instructions packed with your dryer.

Electric Dryer Rating

240V

5400W, 25A, 60Hz

Specification Created 2/13

360505

GFDS260EF/265EF 

GE

®

 8.1 cu. ft. capacity Front Load electric dryer with steam

For answers to your Monogram,

®

 Cafe

 Series 

or

 

Profile

 Series appliance questions, visit 

our website at geappliances.com or call GE 

Answer Center

®

 service, 800.626.2000.

4.655

"

25.306

"

51.960

"

Summary of Contents for GFDS260EF

Page 1: ...st be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer Electric Dryer Rating 240V 5400W 25A 60Hz Specification Created 2 13 360505 GFDS260EF 265EF GE 8 1 cu ft capacity Front Load electric dryer with steam For answers to your Monogram Cafe Series orProfile ...

Page 2: ...o overhead cabinets ceilings etc is 52 Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Ins...

Page 3: ...o a common duct or plenum with a kitchen exhaust since the combination of lint and grease could create a fire hazard Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts bird nesting etc The wall cap must also be located at least 12 above the ground or any other obstruction with the opening pointed down For more information on venting kits and accessories please call 1 ...

Page 4: ...nd that last sock in the washer and dryer thanks to a bright energy efficient and long lasting LED light Stainless steel drum Resists rust and helps protect clothes HE Sensor Dry Keep your clothes looking and feeling their best with dual thermistors that continually sense and monitor moisture and temperature to prevent over drying eMonitor Get the energy saving insight you need to reduce your util...