background image

WARNING 

RISK OF FIRE

• To reduce the risk of severe injury or death, follow all installation instructions.

• Clothes dryer installation must be performed by a qualified installer.

• Install the clothes dryer according to these instructions and in accordance with local 

codes.

• 

California Safe Drinking Water and Toxic Enforcement Act

This act requires the governor of California to publish a list of substances known to the 

state to cause cancer, birth defects or other reproductive harm and requires businesses 

to  warn  customers  of  potential  exposure  to  such  substances.  Gas  appliances  can 

cause minor exposure to four of these substances, namely benzene, carbon monoxide, 

formaldehyde and soot, caused primarily by the incomplete combustion of natural gas 

or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure to 

these substances can be minimized further by properly venting the dryer to the outdoors.

• This dryer must be exhausted to the outdoors.

• Use only rigid metal 4” diameter ductwork inside the dryer cabinet and use only UL 

approved transition ducting between the dryer and the home duct.

• DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible metal 

(semirigid or foil-type) duct is installed, it must be UL listed and installed in accordance 

with the instructions found in “Connecting The Dryer To House Vent” on page 5 of this 

manual. Flexible venting materials are known to collapse, be easily crushed, and trap 

lint. These conditions will obstruct dryer airflow and increase the risk of fire.

• Do not install or store this appliance in any location where it could be exposed to 

water and or weather.

• Save these instructions. (Installers: Be sure to leave these instructions with the 

customer).

IN THE COMMONWEALTH OF MASSACHUSETTS

• This product must be installed by a licensed plumber  or gas fitter.

• When using ball-type gas shut-off valves, they shall be the T-handle type.

• A flexible gas connector, when used, most not exceed 3 feet. 

Installation

Instructions

Gas Dryer

10

Questions on Installation? Call: 1-800-GECARES (US) or 1-800-561-3344 (Canada)

or Visit our Web site at: 

www.GEAppliances.com (US)

BEFORE YOU BEGIN

Read these instructions 

completely and carefully.

IMPORTANT-

 Save these 

instructions for local inspector’s 

use.

IMPORTANT-

 Observe all  

governing codes and ordinances.

 Note to Installer - Be sure to 

leave these instructions with the 

customer.

• Note to Customer - Keep 

these instructions with your 

Use and Care Book for future 

reference.

• Before the old dryer is removed 

from  service or discarded, 

remove the dryer door.

• Service information and the 

wiring diagram are located in 

the control console.

• Do not allow children on or in 

the appliance. Close supervision 

of children is necessary when 

the appliance is used near 

children.

• Install the dryer where the  

temperature is above 50°F for 

satisfactory operation of the 

dryer control system.

31-16630-1    03-11  GE

234D1052P004

Step 1  Verify your gas installation (see section 2).

Step 2  Prepare the area and exhaust for installation of new dryer 

(see section 1).

Step 3  Check and ensure the existing external exhaust is clean (see 

section 1) and meets attached installation specifications (see 

section 6).

Step 4  Remove the foam shipping pads (see section 1).

Step 5  Move the dryer to the desired location.

Step 6  Level your dryer (see section 8).

Step 7  Connect the gas supply (see section 3) and check for leaks 

(see section 4).

Step 8  Connect the external exhaust (see section 7).

Step 9  Connect the power supply (see section 5).

Step 10 Check the operation of the power supply, gas connections, 

and venting.

Step 11 Place the owners manual and the installation instructions in a 

location where they will be noticed by the owner.

For alcove or closet installation, see section 9.

For bathroom or bedroom installation, see section 10.

For mobile or manufactured home, see section 11.

For side or bottom exhaust, see section 12.

LEVEL

8" PIPE WRENCH

10" ADJUSTABLE WRENCHES

 (x2)

TOOLS YOU WILL NEED

SLIP JOINT PLIERS

FLAT BLADE SCREWDRIVER

 

MATERIALS YOU WILL NEED

GLOVES

SAFETY

GLASSES

4" DUCT

CLAMPS (2)

OR

4" SPRING

CLAMPS (2)

EXHAUST

HOOD

4" DIA. METAL

ELBOW

4" DIA. FLEXIBLE METAL (SEMI-RIGID)

UL LISTED TRANSITION DUCT

(IF NEEDED)

 KIT WX08X10077 (INCLUDES 2 ELBOWS)

4" DIA. METAL DUCT

(RECOMMENDED)

4" DIA. FLEXIBLE METAL (FOIL TYPE)

UL LISTED TRANSITION DUCT

(IF NEEDED.)

DUCT TAPE

SOAP SOLUTION

FOR LEAK DETECTION

PIPE

COMPOUND

FLEXIBLE GAS LINE CONNECTOR

Summary of Contents for GFDS350GLWW

Page 1: ...sit our Web site at www GEAppliances com US BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the customer Note to Customer Keep these instructions with your Use and Care Book for future reference Before the old ...

Page 2: ...EL GAS CODE ANSI Z223 This gas dryer is equipped with a Valve Burner Assem bly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVER SIONS MUST BE MADE BY PROPERLY TRAINED AND QUALI FIED PERSONNEL AND IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE REQUIREMENTS The dryer must be disconnected from the ...

Page 3: ...ealant CAUTION Use adaptors as shown Connector nuts must not be connected directly to pipe threads APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET Tighten the flexible gas line using two adjustable wrenches APPLY PIPE COMPOUND TO ALL MALE THREADS Tighten all connections using two adjustable wrenches Do not overtorque gas connections Check all connections for leaks with soapy solution or equ...

Page 4: ...LLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST LENGTH 4 DIA 4 4 DIA Exhaust Hood Types No of 90º Elbows Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 0 1 2 3 4 RECCOMMENDED MAX LENGTH 5 ...

Page 5: ...azard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Do n...

Page 6: ...K Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear For many applications installing elbows at both the dryer and the wall is highly recommended see illustrations below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying...

Page 7: ...MUST be vented to the outdoors with the termination securely fastened to the mobile home structure See EXHAUST INFORMATION section 6 The vent MUST NOT be terminated beneath a mobile or manufactured home The vent duct material MUST BE METAL KIT 14 D346 33 MUST be used to attach the dryer securely to the structure The vent MUST NOT be connected to any other duct vent or chimney Do not use sheet meta...

Page 8: ...elbow as shown above DUCT TAPE CAUTION Use 4 rigid metal ducting only inside the dryer Internal duct joints must be secured with tape otherwise they may sepa rate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in ...

Page 9: ... Siga todos los códigos y ordenanzas vigentes Nota al instalador Asegúrese de dejar estas instrucciones con el consumidor Nota al consumidor Mantenga estas instrucciones con el Manual de uso y cuidados para referencia futura Antes de que la secadora antigua sea retirada del servicio o elimi nada quítele la puerta La información sobre reparaciones y el diagrama del cableado se en cuentran en la con...

Page 10: ...anzas locales o si no las hubiera con el CÓDIGO NACIONAL DE GAS ANSI Z223 Esta secadora a gas está equipada con un montaje de válvula y quemador para utilizar sólo con gas natural Mediante el kit de conversión WE25X0217 la organización de atención local puede convertir esta secadora para su uso con gas propano LP TODAS LAS CONVERSIONES DEBEN LLEVARLAS A CABO PERSONAL CAPACITADO Y CALIFICADO EN CUM...

Page 11: ...exión no deben conectarse directa mente en las roscas de la tubería APLIQUE COMPUESTO PARA TUBERÍA AL ADAPTADOR Y A LA ENTRADA DE GAS DE LA SECADORA Ajuste la tubería flexible de gas utilizando dos llaves ajustables APLIQUE COMPUESTO PARA TUBERÍA EN TODAS LAS ROSCAS MACHO Ajuste todas las conexiones mediante dos llaves ajustables No ajuste de más las conexiones de gas Controle todas las conexiones...

Page 12: ...ad de codos del sistema de salida dependen del tipo de conducto la cantidad de curvas la clase de campana de salida cubierta de pared y todas las condiciones indicadas a continuación La longitud máxima del conducto para conductos rígidos de metal se indica en la siguiente tabla 4 DIA 4 4 DIA 90 Feet 60 Feet 45 Feet 35 Feet 25 Feet 0 1 2 3 4 LONGITUD DE SALIDA LONGITUD MÁXIMA RECOMENDADA Tipos de c...

Page 13: ... de una longitud mayor a la especificada en la tabla de longitud de salida Los conductos más largos acumulan pelusa lo que genera un riesgo potencial de incendio Nunca instale un filtro dentro o sobre el conducto de salida Esto provocará la acumulación de pelusas lo que genera un riesgo potencial de incendio No arme la red de conductos con sujeciones que se extiendan dentro del conducto Estas suje...

Page 14: ...LAR FRENTE A PARTE TRASERA Stand the dryer upright near the final location and adjust the 4 leveling legs at the corners to ensure that the dryer is level from side to side and front to rear Para muchas aplicaciones se recomienda enfáticamente la instalacióndecodosenlasecadorayenlapared verilustraciones de abajo Los codos permiten que la secadora se ubique cerca de la pared sin torcer o aplastar e...

Page 15: ...norma no sea aplicable con la NORMA NACIONAL ESTADOUNIDENSE PARA CASAS MÓVILES ANSI NFPA Nº 501B La secadora DEBE tener ventilación al exterior con la terminación bien sujeta a la estructura de la casa móvil Ver la INFORMACIÓN SOBRE SALIDA sección 6 La ventilación NO DEBE terminar debajo de una casa móvil o prefabricada El material del conducto de ventilación DEBE SER METAL DEBEutilizarseelKIT14 D...

Page 16: ...A PRECAUCIÓN Utilice un conducto de metal rígido de 4 sólo dentro de la secadora Las juntas del con ducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad CÓMO AGREGAR LA PLACA DE CUBIERTA A LA PARTE TRASERA DEL GABINETE Conecte los codos y conductos de metal estándar para completar el sistema de salida Cubra la abertura trasera con la placa Kit W...

Reviews: