GTX33EASK
GE Appliances 6.2 Cu. Ft. Capacity
Aluminized Alloy Drum Electric Dryer
For answers to your Monogram, GE Café
™
Series, GE Profile
™
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Revised 5/16
ELECTRIC DRYER RATING:
240V
5600W
24A
60Hz
208V
4400W
22A
60Hz
EXHAUST OPTION:
4-way rear, right,
left and bottom
CIRCUIT REQUIREMENTS:
An
individual, properly-grounded branch
circuit, protected by a 30-amp circuit
breaker or a time-delay fuse, is required.
NOTE:
Dryer wall outlet must be
located within 36" of service cord entry
and acessible when dryer is mounted in
position.
INSTALLATION INFORMATION:
For complete information, see installation
instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
22 1/2"
26 3/4"
4"
1 3/4"
3 1/4"
4 1/4"
37 1/2"
44"
27"
5"
POWER CORD 4 1/2"
11 3/4"
SIDE VIEW
REAR VIEW
Listed by
Underwriters
Laboratories
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on
the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 1" front, top and rear
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in.
of open area equally distributed. If this closet contains both a washer and a dryer, doors must
contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the
National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 1" rear
DRYER EXHAUSTING INFORMATION :
Use metal duct only, vertical and horizontal ducting.