GTX33EASK 

GE Appliances 6.2 Cu. Ft. Capacity
Aluminized Alloy Drum Electric Dryer

For answers to your Monogram, GE Café

 Series, GE Profile

 Series or 

GE Appliances product questions, visit our website at geappliances.com 
or call GE Answer Center

®

 Service, 800.626.2000.

Specification Revised 5/16

ELECTRIC DRYER RATING:

240V

5600W

24A

60Hz

208V

4400W

22A

60Hz

EXHAUST OPTION: 

4-way rear, right, 

left and bottom

CIRCUIT REQUIREMENTS:  

An 

individual, properly-grounded branch 
circuit, protected by a 30-amp circuit 
breaker or a time-delay fuse, is required.

NOTE: 

Dryer wall outlet must be 

located within 36" of service cord entry 
and acessible when dryer is mounted in 
position.

INSTALLATION INFORMATION:

  

For complete information, see installation 
instructions packed with your dryer.

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

22 1/2"

26 3/4"

4"

1 3/4"

3 1/4"

4 1/4"

37 1/2"

44"

27"

5"

POWER CORD 4 1/2"

11 3/4"

SIDE VIEW

REAR VIEW

Listed by 

Underwriters 

Laboratories

SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:

 

-  If your dryer is approved for installation in an alcove or closet, it will be stated on a label on  

the dryer back.

-  The dryer MUST be exhausted to the outside.
-  Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 

0" either side; 1" front, top and rear

-  Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in.  

of open area equally distributed. If this closet contains both a washer and a dryer, doors must 
contain a minimum of 120 sq. in. of open area equally distributed.

-    No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

BATHROOM OR BEDROOM INSTALLATION:

-  The dryer MUST be exhausted to the outdoors.
-  The installation must conform with the local codes, or in the absence of local codes, with the 

National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:

-  Minimum clearances to combustible surfaces are: 0" both sides; 1" rear

DRYER EXHAUSTING INFORMATION :  

Use metal duct only, vertical and horizontal ducting.