background image

DIMENSIONS AND 
CLEARANCES

Provide adequate clearances between the 
range and adjacent combustible surfaces. 
These dimensions must be met for safe use 
of your range. 

Allow 30” (76.2 cm) minimum clearance 
between burners and bottom of unprotected 
wood or metal cabinet, or allow a 24” (61 cm) 
minimum when bottom of wood or metal cabinet 
is protected by no less than 1/4” (6.4 mm) thick 
flame-retardant millboard covered with no less 

than No. 28 MSG sheet metal (.015” [.38 mm] 
thick), .015” (.38 mm) thick stainless steel, .025” 
(0.64 mm) aluminum or .020” (0.5 mm) copper.

Installation of a listed microwave oven or 
cooking appliance over the cooktop shall 
conform to the installation instructions packed 
with that appliance.

For island installation, maintain 2-1/2” 
minimum from cutout to back edge of 
countertop and 3” minimum from cutout to side 
edges of countertop.

CONNECTOR HOOKUP

TOOLS YOU WILL NEED

MATERIALS YOU MAY NEED

Ŷ

Gas line shut-off valve

Ŷ

Pipe joint sealant or UL-approved pipe thread 
tape with Teflon* that resists action of natural 
and propane gases

Ŷ

Flexible metal appliance connector (1/2” I.D.). 
A 5-foot length is recommended for ease of 
installation but other lengths are acceptable. 
Never use an old connector when installing a 
new range.

Ŷ

Flare union adapter for connection to gas 
supply line (3/4” or 1/2” NPT x 1/2” I.D.)

Ŷ

Flare union adapter for connection to pressure 
regulator on range (1/2” NPT x 1/2” I.D.)

Ŷ

Liquid leak detector or soapy water.

*Teflon: Registered trademark of DuPont

Flat-blade 

screwdriver

Pipe wrenches (2)

(one for backup)

Phillips 

screwdriver

Open-end or  

adjustable wrench

Pencil and ruler

Level

Drill, awl or nail

Pressure 
regulator

Gas Flow into Range

Gas Flow into Range

Flex 
connector 
(6 ft. max.)

Adapter

Installer: Inform the consumer of the location of the gas shut-off valve.

1/2” or 3/4”  

Gas pipe

Adapter

Gas  
shut-off  
valve

Pressure  
regulator

Elbow

Elbow

Nipple

Union

Nipple

Gas  
shut-off  
valve

1/2” or 3/4” 

Gas pipe

Flexible

Option

Rigid Pipe

Option

IN THE COMMONWEALTH 
OF MASSACHUSETTS

Ŷ

This product must be installed by a licensed 
plumber or gas fitter.

Ŷ

When using ball type gas shut-off valves, 
they shall be the T-handle type.

Ŷ

A flexible gas connector, when used, must 
not exceed 5 feet.

BEFORE YOU BEGIN
IMPORTANT —

 

Save these 

instructions for local inspector’s use.

IMPORTANT 

 Observe all governing 

codes and ordinances.

IMPORTANT 

 Remove all packing 

material and literature from oven before 
connecting gas and electrical supply to range.

 

IMPORTANT 

 To avoid damage 

to your cabinets, check with your builder 
or cabinet supplier to make sure that the 
materials used will not discolor, delaminate 
or sustain other damage. This oven has been 
designed in accordance with the requirements 
of UL and CSA International and complies 
with the maximum allowable wood cabinet 
temperatures of 194°F (90°C).

Note to Installer

 – Be sure to leave these 

instructions with consumer.

Note to consumer

 – Keep these instructions 

for future reference.

Servicer

 – The electrical diagram is in an 

envelope attached to the back of the range.

Proper installation is the responsibility of the 
installer.

Product failure due to improper installation is 
not covered under warranty.

Before installing your range on linoleum or 
any other synthetic floor covering, make sure 
the floor covering can withstand 180°F without 
shrinking, warping or discoloring. Do not install 
the range over carpeting unless a sheet of 
1/4” thick plywood or similar insulator is placed 
between the range and carpeting.

Mobile Home - Additional Installation 
Requirements

The installation of this range must conform 
to the Manufactured Home Construction and 
Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile 
Home Construction and Saftey, Title 24, 
HUD Part 280). When such standard is not 
applicable, use the Standard for Manufactured 
Home Installations, ANSI A225.1/NFPA 501A 
or with local codes.

In Canada, the installation of this range must 
conform with the current standards CAN/CSA-
A240-latest edition, or with local codes.

When this range is installed in a mobile 
home, it must be secured to the floor during 
transit. Any method of securing the range 
is adequate as long as it conforms to the 
standards listed above.

WARNING

FIRE OR EXPLOSION 
HAZARD

If the information in this manual is not followed 
exactly, a fire or explosion may result causing 
property damage, personal injury or death.

Installation must be performed by a qualified 
installer.

Read these instructions completely and carefully.

Installation of this range must conform with 
local codes, or in the absence of local codes, 
with the National Fuel Gas Code, ANSI Z223.1/
NFPA.54, latest edition. In Canada, installation 
must conform with the current Natural Gas 
Installation Code, CAN/CGA-B149.1 or the 
current Propane Installation Code, CAN/CGA-
B149.2, and with local codes where applicable. 
This range has been design-certified by 
CSA International according to ANSI Z21.1, 

latest edition and Canadian Gas Association 
according to CAN/CGA-1.1 latest edition.

When installing a gas appliance the use of 
old flexible connectors can cause gas leaks 
and personal injury. Always use a 

NEW

 

flexible connector.

Leak testing of the appliance shall be conducted 
according to the manufacturer instructions.

The range must be electrically grounded in 
accordance with local codes or, in the absence 
of local codes, in accordance with the National 
Electrical Code (ANSI/NFPA 70, latest edition). 
In Canada, electrical grounding must be 
in accordance with the current CSA C22.1 
Canadian Electrical Code Part 1 and/or local 
codes. See Electrical Connections in this section.

Do not install this product with an air curtain 
hood or other range hood that operates by 
blowing air down on the cooktop.  This airflow 
may interfere with operation of the gas burners 
resulting in fire or explosion hazard.

1

  GAS SUPPLY

WARNING

 

Fire Hazard: Do not use 

a flame to check for gas leaks.

WARNING

 

Explosion Hazard: Do 

not exceed 25 ft-lbs of torque when making 
gas line connections. Overtightening may 
crack the pressure regulator resulting in fire 
or explosion hazard.
Gas Pressure Regulator

You must use the gas pressure regulator supplied 
with this range. For proper operations the inlet 
pressure to the regulator should be as follows:

   Natural Gas:

  Minimum pressure: 6” of Water Column
  Maximum pressure: 13” of Water Column

   Propane Gas:

  Minimum pressure: 11” of Water Column
  Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure 
contact local gas supplier.

Shut off the main gas supply valve before 
disconnecting the old range and leave it off 
until the new hook-up has been completed. 
Don’t forget to relight the pilot on other gas 
appliances when you turn the gas back on.

Because hard piping restricts movement of 
the range, the use of a CSA International-
certified flexible metal appliance connector is 
recommended unless local codes require a 
hard-piped connection. 
If the hard piping method is used, you must 
carefully align the pipe; the range cannot be 
moved after the connection is made.

To prevent gas leaks, put pipe joint compound 
on, or wrap pipe thread tape with Teflon* 
around, all male (external) pipe threads. 
A.  Install a manual shut-off valve in the gas line 

in an easily accessed location outside of the 
range. Make sure everyone operating the 
range knows where and how to shut off the 
gas supply to the range.

B.  Install male 1/2” flare union adapter to the 

1/2” NPT internal thread at inlet of regulator. 
Use a backup wrench on the regulator fitting 
to avoid damage.

C.  Install male 1/2” or 3/4” flare union adapter 

to the NPT internal thread of the manual 
shut-off valve, taking care to back-up the 
shut-off valve to keep it from turning.

D.  Connect flexible metal appliance connector 

to the adapter on the range. Position range 
to permit connection at the shut-off valve.

E.  When all connections have been made, make 

sure all range controls are in the off position 
and turn on the main gas supply valve. 
Use a liquid leak detector at all joints and 
connections to check for leaks in the system.

When using pressures greater than 1/2 psig 
to pressure test the gas supply system of the 
residence, disconnect the range and individual 
shut-off valve from the gas supply piping. When 
using pressures of 1/2 psig or less to pressure 
test the gas supply system, simply isolate the 
range from the gas supply system by closing 
the individual shut-off valve.
When checking for proper operation of the 
regulator, the inlet pressure must be at least 1” 
greater than the operating (manifold) pressure 
as given on rating label of product. 
*Teflon: Registered trademark of DuPont

2

  ELECTRICAL 

CONNECTIONS

WARNING

 

Shock Hazard: This 

appliance must be properly grounded. 
Failure to do so can result in electric shock.

Electrical Requirements - 

120-volt, 60 Hertz, 

properly grounded dedicated circuit protected 
by a 15-amp or 20-amp circuit breaker or time 
delay fuse.

NOTE: 

Use of automatic, wireless, or wired 

external switches that shut off power to the 
appliance are not recommended for this product.

Grounding

The power cord of this appliance is equipped 
with a three-prong (grounding) plug which plugs 
into a standard three-prong grounding wall 
receptacle to minimize the possibility of electric 
shock hazard from this appliance.

The customer should have the wall receptacle 
and circuit checked by a qualified electrician to 
make sure the receptacle is properly grounded.

Where a standard two-prong wall receptacle is 
encountered, it is the personal responsibility and 
obligation of the customer to have it replaced with 
a properly grounded three-prong wall receptacle.

DO NOT, UNDER ANY CIRCUMSTANCES, 
CUT OR REMOVE THE THIRD (GROUND) 
PRONG FROM THE POWER CORD. DO 
NOT USE AN ADAPTER. DO NOT USE AN 
EXTENSION CORD.

Ground Fault Circuit Interrupters (GFCI’s) are 
not required or recommended for gas range 
receptacles. Performance of the range will not be 
affected if operated on a GFCI-protected circuit 
but occasional nuisance tripping of the GFCI 
breaker is possible.

4

 CHECK SURFACE 

BURNERS

Push and turn knob to LITE position. You 
will hear a 

clicking

 sound indicating proper 

operation of the spark module. Once the air 
has been purged from the supply lines, burners 
should light within 4 seconds. After burner 
lights, rotate knob out of the LITE position. 
Try each burner in succession until all burners 
have been checked.

Quality of Flames

The flame quality of the burners needs to be 
determined visually.

If burner flames look like (A), call for service. 
Normal burner flames should look like (B) or 
(C), depending on the type of gas you use

With propane gas, some yellow tipping on outer 
cones is normal.

FOR YOUR SAFETY:

WARNING

 Before beginning 

the installation, switch power off at 
service panel and lock the service 
disconnecting means to prevent power 
from being switched on accidentally. 
When the service disconnecting 
means cannot be locked, securely 
fasten a prominent warning device, 
such as a tag, to the service panel.

If you did not receive an anti-tip bracket with your 
purchase, call 1.800.626.8774 to receive one at 
no cost. (In Canada, call 1.800.561.3344.) For 
installation instructions of the bracket, 
visit: www.GEAppliances.com. 
(In Canada, www.GEAppliances.ca.)

Anti-Tip Bracket 

Kit Included

Ensure proper 
ground exists 
before use

WHEN ALL HOOKUPS ARE 
COMPLETED

Make sure all controls are left in the off 
position. Make sure the flow of combustion and 
ventilation air to the range is unobstructed.

Check that all packing materials and tape 
have been removed. This will include tape on 
metal panel under control knobs (if applicable), 
adhesive tape, wire ties, cardboard and 
protective plastic. Failure to remove these 
materials could result in damage to the 
appliance once the appliance has been turned 
on and surfaces have heated.

DIMENSIONS AND CLEARANCES (CONT.)

GAS PIPE AND ELECTRICAL OUTLET LOCATIONS

INSTALLATION INSTRUCTION

31-10998-3   06-17   GEA

JGBS62, JGB645, JGBS66, JGB660, JGB700

5

 CHECK BAKE AND 

BROIL BURNERS

Ŷ6HW%DNHIXQFWLRQWRƒ)%XUQHUVKRXOG

light in 30 to 90 seconds.

Ŷ&KHFNEURLOEXUQHUXVLQJWKHVDPH

method as the bake burner.

•  A child or adult can tip the range and be killed.

•  Install the anti-tip bracket to the wall or floor.

•  Engage the range to the anti-tip bracket by sliding the 
  range back such that the foot is engaged.

•  Re-engage the anti-tip bracket if the range is moved.

•  Failure to do so can result in death or serious burns
  to children or adults.

Tip-Over Hazard

WARNING

Installation Instructions
Range

Questions? Call GE Appliances at 1.800.GE.CARES (1.800.432.2737) or visit 
www.GEAppliances.com. In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca.

CONVERTING TO PROPANE 
GAS (OR CONVERTING 
BACK TO NATURAL GAS 
FROM PROPANE)

This range leaves the factory set for use with 
natural gas. If you want to convert to propane 
gas, the conversion must be performed by a 
qualified propane gas installer.

The conversion orifices and instructions can 
be found on back of the range.

Keep these instructions and all orifices in 
case you want to convert back to natural gas.

INSTALLATION AT HIGH ALTITUDE

Over 6000ft, product configured for natural gas or propane requires installation of kit 
WB49X2541. Follow the instructions included with the kit.

Rear of Range

Orifice Strip 
(location 
may vary) 

Spirit level

X

Y

Minimum to 
cabinets on 
either side  
of the range

30”

30” 
Minimum

15”

3” 
Minimum 
clearance to 
right wall

Maximum 

depth for 

cabinets above 

countertops

Front edge 
of the range 
side panel 
forward from 
cabinet

0” 
To cabinets 
below cooktop 
and at the 
range back

1/4”

6” 

Minimum 

clearance  

to left wall

0”

18” 

To cabinets 

below 

cooktop 

and at the 

range back

Recommended area for 120V 

outlet on rear wall and area for 

through-the-wall

 connection of 

pipe stub and shut-off valve.

Recommended area 

for 

through-the-floor

 

connection of pipe stub 

and shut-off valve.

CAUTION

 

To prevent 

drafts from affecting burner 
operation, seal all openings 
in floor under appliance and 
behind appliance wall.

(C) Soft blue flames—

Normal for natural gas

(B)  Yellow tips on outer 

cones—

Normal for propane gas

(A) Yellow flames—

Call for service

6

 INSTALL AND CHECK 

ANTI-TIP DEVICE

WARNING

 

Never completely 

remove the leveling leg as the range will not 
be secured to the anti-tip device properly.

Follow instructions supplied with ANTI-TIP 
bracket.

Anti-Tip Bracket 

Kit Included

7

 LEVEL THE RANGE

WARNING

 

Never completely 

remove the leveling leg as the range will not 
be secured to the anti-tip device properly.

A.

  Plug in the unit.

B.

  Measure the height of your countertop at the 

rear of the opening (X).

C.

  Adjust two rear leveling legs so that the rear 

of cooktop is at the same height or higher 
than the counter (Y).

D.

  Slide unit into place.

E.

  Install oven shelves in the oven and position 

the range where it will be installed.

F.

  Check for levelness by placing a spirit 

level on one of the oven shelves. Take two 
readings—with the level placed diagonally 
first in one direction and then the other.

G.

  Adjust front leveling legs until the range is 

level.

H.

  Look under the unit and verify that the rear 

leg is fully engaged with the anti-tip device. If 
not, remove the unit and adjust the height of 
the rear leg so that it is properly engaged.

3

  SURFACE BURNERS

WARNING

 

Fire or Explosion Hazard: 

Do not operate the burner without all burner 
parts in place.

A.  

Burners -

 Place surface burners into 

corresponding positions on cooktop.

B.  

Caps -

 Place caps on proper size burner.

C.  

Single Grates -

 Place the oval (center) 

head/cap assembly over the electrode on 
the cooktop.

Left

Grate

Right
Grate

Center 

Grate or Griddle

or

Front right burner 

Electrode

Electrode

Hole

Cap

Burner

Cap

46 1/4"

28 3/4"

w/ handle

26 1/4"

w/o handle

30"

36 1/4" ± 1/4"

11 1/4"

NOTE:

 Cooktop must be 

at or above counter.

Grate

Cooktop

Counter