background image

TOOLS YOU WILL NEED

MATERIALS YOU MAY NEED

„

  Gas line shut-off valve

„

  Pipe joint sealant or UL-approved pipe thread 

tape with Teflon* that resists action of natural 

and propane gases

„

  Flexible metal appliance connector (1/2

 I.D.). 

A 5-foot length is recommended for ease of 

installation but other lengths are acceptable. 

Never use an old connector when installing a 

new range.

„

  Flare union adapter for connection to gas 

supply line (3/4

 or 1/2

 NPT x 1/2

 I.D.)

„

  Flare union adapter for connection to pressure 

regulator on range (1/2

 NPT x 1/2

 I.D.)

„

  Liquid leak detector or soapy water.

*Teflon: Registered trademark of DuPont

Flat-blade 

screwdriver

Pipe wrenches (2)

(one for backup)

Phillips 

screwdriver

Open-end or  

adjustable wrench

Pencil and ruler

Level

Drill, awl or nail

IN THE COMMONWEALTH OF 

MASSACHUSETTS

„

  This product must be installed by a licensed 

plumber or gas fitter.

„

   When using ball type gas shut-off valves, they 

shall be the T-handle type.

„

   A flexible gas connector, when used, must not 

exceed 3 feet.

Installation Instructions
Range

Questions? 

Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com 

BEFORE YOU BEGIN
,03257$17³

 Save these instructions for 

local inspector’s use.

,03257$17³ 

Observe all governing 

codes and ordinances.

,03257$17³ 

Remove all packing 

material and literature from oven before 

connecting gas and electrical supply to range.

 

,03257$17³ 

To avoid damage to your 

cabinets, check with your builder or cabinet 

supplier to make sure that the materials used will 

not discolor, delaminate or sustain other damage. 

This oven has been designed in accordance with 

the requirements of UL and CSA International 

and complies with the maximum allowable wood 

cabinet temperatures of 194°F (90°C).
Note to Installer – Be sure to leave these 

instructions with consumer.
Note to consumer – Keep these instructions for 

future reference.
Servicer – The electrical diagram is in an 

envelope attached to the back of the range.
Proper installation is the responsibility of the 

installer. 

Product failure due to improper installation is not 

covered under warranty.
Before installing your range on linoleum or any 

other synthetic floor covering, make sure the 

floor covering can withstand 180°F without 

shrinking, warping or discoloring. Do not install 

the range over carpeting unless a sheet of 1/4” 

thick plywood or similar insulator is placed 

between the range and carpeting.
Mobile Home - Additional Installation 

Requirements
The installation of this range must conform to 

the Manufactured Home Construction and Safety 

Standard, Title 24 CFR, Part 3280 (formerly the 

Federal Standard for Mobile Home Construction 

and Saftey, Title 24, HUD Part 280). When such 

standard is not applicable, use the Standard for 

Manufactured Home Installations, ANSI A225.1/

NFPA 501A or with local codes.
In Canada, the installation of this range must 

conform with the current standards CAN/CSA-

A240-latest edition, or with local codes.
When this range is installed in a mobile home, it 

must be secured to the floor during transit. Any 

method of securing the range is adequate as 

long as it conforms to the standards listed above.

WARNING

FIRE OR EXPLOSION HAZARD

If the information in this manual is not followed 

exactly, a fire or explosion may result causing 

property damage, personal injury or death.
Installation must be performed by a qualified 

installer.
Read these instructions completely and carefully.
Installation of this range must conform with 

local codes, or in the absence of local codes, 

with the National Fuel Gas Code, ANSI Z223.1/

NFPA.54, latest edition. In Canada, installation 

must conform with the current Natural Gas 

Installation Code, CAN/CGA-B149.1 or the current 

Propane Installation Code, CAN/CGA-B149.2, and 

with local codes where applicable. This range 

has been design-certified by CSA International 

according to ANSI Z21.1, latest edition and 

Canadian Gas Association according to CAN/

CGA-1.1 latest edition.

When installing a gas appliance the use of old 

flexible connectors can cause gas leaks and 

personal injury. Always use a NEW flexible 

connector.
Leak testing of the appliance shall be conducted 

according to the manufacturer instructions.
The range must be electrically grounded in 

accordance with local codes or, in the absence 

of local codes, in accordance with the National 

Electrical Code (ANSI/NFPA 70, latest edition). 

In Canada, electrical grounding must be in 

accordance with the current CSA C22.1 Canadian 

Electrical Code Part 1 and/or local codes. See 

Electrical Connections in this section.
Do not install this product with an air curtain 

hood or other range hood that operates by 

blowing air down on the cooktop.  This airflow 

may interfere with operation of the gas burners 

resulting in fire or explosion hazard.

FOR YOUR SAFETY:

•  A child or adult can tip the range and be killed.
•  Install the anti-tip bracket to the wall or floor.
•  Engage the range to the anti-tip bracket by sliding the 
  range back such that the foot is engaged.
•  Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns
  to children or adults.

Tip-Over Hazard

WARNING

WARNING

   Before beginning 

the installation, switch power off at 
service panel and lock the service 
disconnecting means to prevent power 
from being switched on accidentally. 
When the service disconnecting means 
cannot be locked, securely fasten a 
prominent warning device, such as a 
tag, to the service panel.

If you did not receive an anti-tip bracket with your 

purchase, call 1.800.626.8774 to receive one at no 

cost. (In Canada, call 1.800.561.3344.) For installation 

instructions of the bracket, visit: www.GEAppliances.com. 

(In Canada, www.GEAppliances.ca.)

Anti-Tip Bracket 

Kit Included

Summary of Contents for JGB720SEJSS

Page 1: ...SI A225 1 NFPA 501A or with local codes In Canada the installation of this range must conform with the current standards CAN CSA A240 latest edition or with local codes When this range is installed in a mobile home it must be secured to the floor during transit Any method of securing the range is adequate as long as it conforms to the standards listed above WARNING FIRE OR EXPLOSION HAZARD If the ...

Page 2: ...conform to the installation instructions packed with that appliance For island installation maintain 2 1 2 minimum from cutout to back edge of countertop and 3 minimum from cutout to side edges of countertop To cabinets below cooktop and at the range back Minimum to cabinets on either side of the range 30 30 Minimum 15 6 Minimum clearance to right wall Maximum depth for cabinets above countertops ...

Page 3: ... the off position and turn on the main gas supply valve Use a liquid leak detector at all joints and connections to check for leaks in the system When using pressures greater than 1 2 psig to pressure test the gas supply system of the residence disconnect the range and individual shut off valve from the gas supply piping When using pressures of 1 2 psig or less to pressure test the gas supply syst...

Page 4: ...on and surfaces have heated 6 INSTALL AND CHECK ANTI TIP DEVICE WARNING Never completely remove the leveling leg as the range will not be secured to the anti tip device properly Follow instructions supplied with ANTI TIP bracket Anti Tip Bracket Kit Included INSTALLATION INSTRUCTION 31 10999 1 07 16 GEA PGB911 PGB930 JGB720 7 LEVEL THE RANGE WARNING Never completely remove the leveling leg as the ...

Page 5: ...da en una casa móvil se deberá asegurar al piso durante el tránsito Cualquier método para asegurar la cocina es adecuado siempre y cuando se realice conforme con los estándares que figuran a continuación ADVERTENCIA RIESGO DE INCENDIO O EXPLOSIÓN Si la información de este manual no se sigue exactamente se podrá producir un incendio o explosión ocasionando daños sobre la propiedad lesiones o la mue...

Page 6: ...lación de la isla deje un espacio mínimo de 2 desde la abertura hasta el extremo trasero de la mesada y un mínimo de 3 desde la abertura hasta los extremos laterales de la mesada Parte Trasera de la Estufa Caja del Orificio la ubicación puede variar Área recomendada para tomacorriente de 120V en la pared trasera y área para la conexión del tubo de escape y la válvula de seguridad a través de la pa...

Page 7: ... los controles de la cocina estén en la posición de apagado y encienda la válvula de suministro principal de gas Use un detector de pérdida de líquido en todas las uniones y conexiones para controlar pérdidas en el sistema Al usar presión superior a psig para controlar la presión del sistema de suministro de gas de la residencia desconecte la cocina y la válvula de cierre individual de la tubería ...

Page 8: ...tes 6 INSTALE Y CONTROLE EL DISPOSITIVO ANTIVOLCADURAS ADVERTENCIA Nunca retire completamente las patas niveladoras ya que la cocina no estará asegurada de forma adecuada al dispositivo antivolcaduras Siga las instrucciones suministradas con el soporte ANTIVOLCADURAS Kit de soporte anti volcaduras incluido INSTRUCCIONES DE INSTALACIÓN 31 10999 1 07 16 GEA PGB911 PGB930 JGB720 5 CONTROLE LOS QUEMAD...

Reviews: