Summary of Contents for JGP626AEV1AA

Page 1: ...pane Installation Code C _ i CGA B149 2 and with local codes where applicable Be sure your cooktop is installed properly by a qualified installer or sen ice tecilmcian Pub r lo 31 10169 This cooktop must be electrically grounded in accor dance with local codes or in their absence with tile National Electrical Code ANSI NFPA No 70 Latest Edition See Grounding Instructions on page 6 In Canada electr...

Page 2: ...for natural gas FOR PROPER OPERATION THE MAXIMUM INLET PRESSURE TO I HE REGULATOR MUST BE NO MORE THAN 14 OF WATER COLUMN PRESSURE For checking the regulator the inlet pressure must be at least I or 3 4 KPA greater than the regulator output setting If the regulator is set for 4 of water column pressure the inlet pressure must be at least 5 if the regulator is set for i0 the inlet pressure must be ...

Page 3: ...NE POS ON _ f __ J l__ _ I Jl _ m S I I II ii i i _ I 4 Change the cooktop burner orifices by A Removing the top grates burner caps and burner heads BURNER GRATE BURNER CAP ql_ BURNER HEAD BURNER _ _ SPARK IGNITER _ MIXER TUBE CHIMNEY PRESSURE REGULATOR A Unscrew the cap B Piaee your thumb against the flat side of the spring retainer and press down to remove the retainer C Carefully look at the sp...

Page 4: ...ices that you removed during the L P Propane conversion and reverse steps 1 6 of the L P Propane conversion section 5 Locate the L P iPropane orifices The L p Propane orifices are shipped in the literature package They will have a digit number and the letter L on one side Each orifice will also show a series of engraved marks I II or III located on the top 43 73 These marks denote the precise loca...

Page 5: ...upply to be sure the manifold pipe has not been moved A misallgnment could cause the valve knob stem to rub on the control panel resulting In a gas leak at the valve STREET EL _IBOW CABINET S_DES _ 7 2 DIA HOLE 120 7 8 FROM FRONT OF COUNTERTOP TO HOLECENTER STEP 4 ELECTRICAL CONNECTION Electrical Requirements Because of potential sal_ty hazards under certain conditions we strongly recommend agains...

Page 6: ...WALL RECEPTACLE COVER SCREW DOES NOT GROUND THE APPLIANCE UNLESS THE SCREW IS METAL AND NOT INSULATED AND THE WALL RECEPTACLE IS GROUNDED THROUGH THE HOUSE WIRING THE CUSTOMER SHOULD HAVE THE CIRCUIT CHECKED BY A QUALIFIED ELECTRICIAN TO MAKE SURE THE RECEPTACLE IS PROPERLY GROUNDED When disconnecting the power cord from the adaptor always hold the adaptor with one hand If this is not done the ada...

Page 7: ...eparately until all burners have been checked out BURNER IGNITION COOKTOP SPARK IGNITION When you turn the cooktop Mmb to LITE the spark igniter makes a series of electric sparks ticking sounds which light the burner During a power failure the burners will not light automatically In an emergency a cooktop burner may be lit with a match by following the steps below 1 Ligtlt a malch and hold the fla...

Page 8: ...NOTES Pub No 31 10169 229c4053P039 1 R_d_ Paper Printed in LaFaye_e Georgia ...