background image

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

320442

Specification Revised 10/07

JKP30BM/CM/WM 

GE

®

 27" Built-In Single Wall Oven

 

Listed by 

Underwriters 

Laboratories

All GE ranges are equipped with 

an Anti-Tip device. The installation 

of this device is an important, 

required step in the installation  

of the range.

KW Rating

240V

3.4

208V

2.6

Breaker Size

240V

20 Amps

208V

20 Amps

Cabinet 

27"

  A – Cabinet width required 

27" min.

  B – Minimum cabinet depth 

23-5/8"

 

C – Opening width 

25" min. - 25-1/4" max

  D – Opening height 

27-5/8" min. - 28-1/8" max.

Oven 

 

  E – Overall depth* 

23-5/8"

  F –  Overall height with trim 

29-7/8" - 30-3/4"

   

Overall height without trim 

29"

  G – Overall width 

26-5/8"

*Depth including door handle is approximately 26-7/10" min. to 

26-8/10" max.

Access 

from

adjacent 

cabinet

required

CL

Suitable

bracing 

to support

runners

18" 

Over centerline

of cabinet

(must support 275 lbs.)

2" x  4" or

equivalent

runners

2" x 4" 

or equiv.

runners

B MIN.

C MIN.

Conduit 48-1/2" long

32-1/2

D

10

A

Allow 3/4"

for overlap

over all edges

of cutout

Locate

junction box

either 5" MIN.

below cutout

floor or 44"

MIN. above 

cutout floor

Minimum

cutout location

from floor

(Minimum 15-5/8"

from floor when

installed below built-in

microwave oven)

E

G

F

20

Note: These ovens are not approved for stackable or 

side-by-side installations.
Note:

 Cabinets installed adjacent to wall ovens must have 

an adhesion spec of at least a 194°F temperature rating.

Note:

 For 27" built-in single ovens, if marks, blemishes or 

the cutout opening is visible above the installed oven, it 

may be necessary to add wood shims under the runners 

and front trim until the marks or openings are covered.

Note:

 Door handle protrudes 3" from door face. Cabinets 

and drawers on adjacent 45° and 90° walls should be 

placed to avoid interference with the handle.

Electric wall ovens are not approved for installation 

with a plug and receptacle. They must be hard wired in 

accordance with installation instructions.
Installation Information:

 Before installing, consult 

installation instructions packed with product for current 

dimensional data. 

Cabinet 

27"

  A – Cabinet width required 

27" min.

  B – Minimum cabinet depth 

23-5/8"

 

C – Opening width 

25" min. - 25-1/4" max

  D – Opening height 

27-5/8" min. - 28-1/8" max.

Oven 

 

  E – Overall depth* 

23-5/8"

  F –  Overall height with trim 

29-7/8" - 30-3/4"

   

Overall height without trim 

29"

  G – Overall width 

26-5/8"

*Depth including door handle is approximately 26-7/10" min. to 

26-8/10" max.

Access 

from

adjacent 

cabinet

required

CL

Suitable

bracing 

to support

runners

18" 

Over centerline

of cabinet

(must support 275 lbs.)

2" x  4" or

equivalent

runners

2" x 4" 

or equiv.

runners

B MIN.

C MIN.

Conduit 48-1/2" long

32-1/2

D

10

A

Allow 3/4"

for overlap

over all edges

of cutout

Locate

junction box

either 5" MIN.

below cutout

floor or 44"

MIN. above 

cutout floor

Minimum

cutout location

from floor

(Minimum 15-5/8"

from floor when

installed below built-in

microwave oven)

E

G

F

20

Dimensions and Installation Information (in inches) 

Reviews: