background image

 WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK

Turn power off before inspection, installation or removal.

Properly ground electrical enclosure.

RISK OF FIRE

Follow all NEC and local codes.

Use only UL or IEC approved wire for input/output

connections. Minimum size 18 AWG (0.82mm

2

).

RISQUES DE DÉCHARGES ÉLECTRIQUES

•  

Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.

Assurez-vous de correctement mettre à la terre le boîtier d’alimentation

électrique.

RISQUES D’INCENDIE

Respectez tous les codes NEC et codes locaux.

N’utilisez que des fils approuvés par UL ou IEC pour les entrées/sorties de

connexion. Taille minimum 18 AWG (0.82mm

2

).

Lumination

TM

 LED Luminaires

Suspended LED Fixture

(Series EP

2

4)

Features

Long life (50,000 hour rated life)

5 year warranty

Dry location rated

BEFORE YOU BEGIN

Read these instructions completely and carefully.

Save These Instructions

Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Each luminaire is to be used with remote driver kit, model no. EP-DKIT400. 

Wiring to be performed by qualified electrician only.

Installation Guide

Summary of Contents for Lumination EP24 Series

Page 1: ...rique RISQUES D INCENDIE Respectez tous les codes NEC et codes locaux N utilisez que des fils approuvés par UL ou IEC pour les entrées sorties de connexion Taille minimum 18 AWG 0 82mm2 LuminationTM LED Luminaires Suspended LED Fixture Series EP24 Features Long life 50 000 hour rated life 5 year warranty Dry location rated BEFORE YOU BEGIN Read these instructions completely and carefully Save Thes...

Page 2: ...rd luminaire 4th luminaire 5th luminaire Distance between canopy sets for left and right luminaires 1193mm 47 in Distance between canopy sets for luminaires in the middle 1207mm 47 5 in Example To install five units in series the distance between canopy sets for the 1st left and 5th right luminaire is 1193mm 47 in and the distance between canopy sets for the 2nd 3rd and 4th middle luminaires is 12...

Page 3: ...uminaire to the matching colored wires from the driver enclosure Connect both green wires to the grounding screw Refer to the EP DKIT400UV and EP DKIT400UD LED Driver Installation Instructions for more information Canopy electrical Strain relief bushing Wires from luminaire Suspension cable Cable coupler Stud To driver enclosure To driver enclosure Junction box in ceiling Crossbar 1 Carefully unpa...

Page 4: ...er spring washer and M8 nuts Screw torque should be between 15 3 0 8kg f For multiple units installed in series all canopy sets will have a power cable except the last canopy Optional Mounting Method Connecting Suspended Fixtures in Series Reattach suspension wire to Y shape suspension wire To adjust height and to level a fixture squeeze the tip of the gripper and pull the suspension cable to the ...

Page 5: ...re Length 18 AWG 0 82 mm2 59 0 ft 18 m 16 AWG 1 31 mm2 98 4 ft 30 m 14 AWG 2 08 mm2 154 2 ft 47 m 12 AWG 3 31 mm2 249 3 ft 76 m Conforms to the following standards Includes fixture s 6 6 ft 2 0 m power cord This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interf...

Reviews: