ZDWT240PBS 

GE Monogram Wine Reserve with Liquid Crystal Privacy Glass

 

Dimensions and Installation Information

Specification Revised 12/06

120040

34-1/2"-35"

24" Min.

23-3/4" 

23-3/4" Min. 

25-1/2" 

Including  

Handle 

34-1/4"-

34-3/4"

23-3/4"

1-1/2" 

Locate Outlet 

9"  

Max.

10-1/2" 

A

Minimum to Wall  

110

°

110

°

 Door  

Swing

21-5/8"

23-5/8"

B

Minimum to Wall

90

°

90

°

 Door  

Swing

10"

Minimum to Wall

4"

Minimum to Wall

Installation Space 

The Monogram

®

 Wine Reserve may be installed beneath a 

countertop or can be used free-standing.
• If installing between frameless cabinets, a 1/2”-wide filler  
  strip or side panel may be required. The filler strip will act  
  as a spacer between the door case and adjacent cabinet  
  and will prevent interference with cabinet door swing. The 
  width of the opening must include filler panels.
Note: When installed, the door should project forward 1” of 
adjacent 24”-deep cabinets.

Location Requirements 

All Monogram Refrigeration Modules may be closed in on 
the top and sides as long as the front is unobstructed for air 
circulation and door swing.
• Do not install these products where the temperatures will  
  go  below 55°F (13°C) or above 90°F (32°C).
•  Do not install where they will be subject to direct sunlight,  
  heat or moisture.
• These products are not designed to be stacked one over  
  the other.

Side-by-Side Installation 

For a complete refreshment center, install a Monogram Wine 
Reserve and Beverage Center together.
• Products must operate from separate properly grounded  
  receptacles.
•  Do not install where they will be subject to direct sunlight,  
  heat or moisture. 

Door Swing Clearances 

All Monogram Refrigeration Modules are factory set for a 
110° door swing. When installed in a corner:
•  Allow the minimum door swing clearances shown.
•  The minimum clearance shown at 90° will allow full  
  extension of drawers and shelves. 

Dimensions and installation instructions are shown in inches.

Listed by 

Underwriters 

Laboratories

Electrical 

A  120V,  60Hz,  15  or  20  amp  power  supply  is  required.  
An  individual  properly  grounded  branch  circuit  or  circuit 
breaker  is  recommended.  Install  a  properly  grounded  
3-prong  electrical  recessed  into  the  back  wall  as  shown. 
Electrical must be located on rear wall as shown. 

Note: GFCI 

(ground fault circuit interrupter) is not recommended. 