For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Listed by
Underwriters
Laboratories
Specification Created 6/08
110113
696Dia7
6"
Wall View
Electrical
Area
84-1/2" max
83-1/2" min
Finished
Opening
75" From
Floor to Bottom
of Electrical
Area
10"
5"
3 1/2"
5"
3 1/2"
24" Cutout Depth
35-1/2"
Finished Width
2-5/16"
Note: Icemaker
water connection
is at the front.
Cold Water
Supply
*Shipping height. The
refrigerator can be adjusted
to fit into a cutout that is
83-1/2" min. to 84-1/2" max.
height. Note that the top case
trim at the front is 1/2" higher
and will overlap upper cabinetry
or soffit. Use leveling legs
and wheels for a maximum
1" height adjustment.
25-3/4" Case Depth
84"* from
floor to
top frame
35" Case Width
83-1/2"*
at Rear
28-11/16"
36" Frame to
Frame Width
Depth Including Handles
The Installation Space
The finished cutout width must be 35-1/2".
Product Dimensions
*
Shipping Height:
The refrigerator
can be adjusted
to fit into a cutout
that is 83-1/2" min.
to 84-1/2" max.
height. The top case
trim at the front
is 1/2" higher and
will overlap upper
cabinetry or soffit.
Use leveling legs
and wheels for a
maximum 1" height
adjustment.
The cutout depth must be 24"
The refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
The cutout depth beneath a soffit
When installed beneath a soffit, the soffit cannot exceed the
24" installation depth shown. The top case trim overlaps the
bottom of the soffit.
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical
must be located on rear wall as shown.
Note:
GFI (ground fault interrupter) is not recommended.
Water Line
The water line can enter the opening through the floor
or back wall. Route GE SmartConnect
™
Kit or 1/4" O.D.
copper tubing between the cold water line and the water
connection location at the front of the refrigerator. The
tubing must be long enough to extend to the front of the
refrigerator. The installation of an easily accessible shut-off
valve in the water line is required.
605Dia20
25"
Min. to
Wall
130
°
130
°
Door Swing
23-7/8"
Behind
Frame
36-3/4"
zicp_bf_ref_qs_art
90
°
90
°
Door Swing
5" Min.
to Wall
Door Swing Clearances
The installation must allow for clearances to adjacent walls
or cabinets. These refrigerators are equipped with a 2-
position door stop. The factory-set 130° door swing can be
adjusted to 90° if clearance to adjacent cabinets or walls is
restricted.
Allow 25" minimum clearances for a full 130° door swing.
Allow 15" for pan removal.
• 5" minimum clearance is required when the door swing is
adjusted to 90°. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.
Dimensions and Installation Information (in Inches)
ZICP360NX