background image

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

Listed by 

Underwriters 

Laboratories

Specification Created 6/08

110113

696Dia7

6"

Wall View

Electrical

Area

84-1/2" max

83-1/2" min 

Finished 

Opening

75" From

Floor to  Bottom 

of Electrical

Area

10"

5"

3 1/2"

5"

3 1/2"

24" Cutout Depth

35-1/2"

Finished Width

2-5/16"

Note: Icemaker 

water connection 

is at the front.

Cold Water

Supply

*Shipping height. The 

  refrigerator can be adjusted 

  to fit into a cutout that is 

  83-1/2" min. to 84-1/2" max. 

  height. Note that the top case 

  trim at the front is 1/2" higher 

  and will overlap upper cabinetry 

  or soffit. Use leveling legs 

  and wheels for a maximum 

  1" height adjustment.  

25-3/4" Case Depth

84"* from

floor to 

top frame 

35" Case Width

83-1/2"*

at Rear 

28-11/16"

36" Frame to 

Frame Width

Depth Including Handles

The Installation Space

 

The finished cutout width must be 35-1/2".

Product Dimensions

Shipping Height:

 

The refrigerator 

can be adjusted 

to fit into a cutout 

that is 83-1/2" min. 

to 84-1/2" max. 

height. The top case 

trim at the front 

is 1/2" higher and 

will overlap upper 

cabinetry or soffit. 

Use leveling legs 

and wheels for a 

maximum 1" height 

adjustment.

The cutout depth must be 24"

 

The refrigerator will project forward, slightly beyond adjacent 
cabinetry, depending on your installation.

The cutout depth beneath a soffit

 

When installed beneath a soffit, the soffit cannot exceed the 
24" installation depth shown. The top case trim overlaps the 
bottom of the soffit.

Electrical

 

A 115V, 60Hz., 15 or 20 amp power supply is required. An 
individual properly grounded branch circuit or circuit breaker 
is recommended. Install a properly grounded 3-prong 
electrical receptacle recessed into the back wall. Electrical 
must be located on rear wall as shown.

 

Note:

 

GFI (ground fault interrupter) is not recommended.

Water Line

 

The water line can enter the opening through the floor 
or back wall. Route GE SmartConnect

 Kit or 1/4" O.D. 

copper tubing between the cold water line and the water 
connection location at the front of the refrigerator. The 
tubing must be long enough to extend to the front of the 
refrigerator. The installation of an easily accessible shut-off 
valve in the water line is required.

605Dia20

25"

Min. to

Wall

130

°

130

°

 Door Swing

23-7/8"

Behind

Frame

36-3/4"

zicp_bf_ref_qs_art

90

°

90

°

 Door Swing

5" Min.

to Wall

Door Swing Clearances

The installation must allow for clearances to adjacent walls 
or cabinets. These refrigerators are equipped with a 2-
position door stop. The factory-set 130° door swing can be 
adjusted to 90° if clearance to adjacent cabinets or walls is 
restricted.

Allow 25" minimum clearances for a full 130° door swing. 
Allow 15" for pan removal. 
•  5" minimum clearance is required when the door swing is 

adjusted to 90°. If the 90° door stop position is used, pan 
access is maintained, but pan removal is restricted.

Dimensions and Installation Information (in Inches)