background image

•  T E C H N I C A L   D A T A   S H E E T  •

MONOGRAM 36" WALL-MOUNTED HOOD

IMPORTANT SAFETY NOTICE

ThIS INFORMATION IS INTENdEd FOR uSE bY  

PERSONS  POSSESSINg AdEquATE bACkgROuNdS  

OF ElECTRICAl, ElECTRONIC ANd MEChANICAl  

ExPERIENCE. ANY ATTEMPT TO REPAIR A MAjOR  

APPlIANCE MAY RESulT IN PERSONAl INjuRY ANd 

PROPERTY  dAMAgE. ThE MANuFACTuRER OR SEllER 

CANNOT bE RESPONSIblE FOR ThE INTERPRETATION OF 

ThIS INFORMATION, NOR CAN IT ASSuME ANY lIAbIlITY 

IN CONNECTION wITh ITS uSE.

DISCONNECT POWER BEFORE SERVICING

IMPORTANT:

 RECONNECT All gROuNdINg dEVICES.

All PARTS OF ThIS APPlIANCE CAPAblE OF CONduCTINg 

ElECTRICAl CuRRENT ARE gROuNdEd. IF IT IS NECESSARY 

TO REMOVE gROuNdINg wIRES, SCREwS, STRAPS, ClIPS, 

NuTS OR wAShERS uSEd TO COMPlETE A PATh TO gROuNd, 

ThEY MuST bE RETuRNEd TO ThEIR ORIgINAl POSITIONS 

ANd PROPERlY FASTENEd bEFORE POwER IS  

RECONNECTEd.

gROuNdINg SPECIFICATIONS

Ground Path Resistance  0.10 

Max.

Insulation Resistance 

250K  Min.

INSTAllATION REquIREMENTS:

Power Supply

The hood must be connected to a supply circuit of the proper  

voltage and frequency as specified on the rating plate. Wire size 

must conform to the National Electrical Code or the prevailing local 

code. The rating plate is located on the left side and is visible when 

filter is removed.

    wARNINg:

 IMPROPER CONNECTION OF  

AluMINuM HOUSE WIRING TO COPPER LEADS CAN RESULT 

IN A SERIOUS PROBLEM. USE ONLY CONNECTORS DESIGNED 

FOR JOINING COPPER TO AluMINuM AND FOLLOW THE 

MANUFACTURER’S RECOMMENDED PROCEDURE CLOSELY.

MOdEl NuMbER ZV750/ZV755

IMPORTANT

SERVICE INFORMATION

DO NOT DISCARD

Pub. No. 31-14783

PuSh buTTON OPERATION ANd lEd dISPlAY

Fan Keypad Operation
  1
  ON/OFF – Remembers the last fan speed used
  2  Decreases speed
  3  Increases speed
  4  Boost speed
  5  Delayed fan shutoff – Choose 5, 10 or 20 minutes by pushing 

this button (see item 10).

Hood Lights Keypad Operation
  6
  Light ON/OFF –  Remembers the last light level used
  7  Dims light
  8  Brightens light
Display LEDs
  9
  Clean indicator light illuminates after 30 hours of “ON” time 

to remind you to clean the metal grease filters. The light 

stays on until the filters are replaced. If the lights stay on 

and the filters are in, adjust the right side filter in place.  

Then the timer resets automatically.

10  Indicates the time the fan is set to run
11  Fan operating symbol

hAlOgEN lAMPS

The four halogen lamps are the push-in type rated at 120V and  

25 watts with a G-9 base. 
TO ChANgE ThE lAMPS

FIlTER MICROSwITCh

A microswitch is mounted in the filter channel on the right side. It 

senses when filters are removed. The red display light glows when 

the filter is removed, if the filter is not making contact with the switch, 

or after 30 hours of fan operation to remind the user to clean the 

filters. Make sure the filter is seated properly when installed and the 

filter light is not on.

TO REMOVE ANd REPlACE FIlTER MICROSwITCh

Remove 2 screws and lift out the switch. The harness is connected 

to the PCB assembly. Refer to the schematic to locate and 

disconnect the control CN7.

ACCESS TO lIghTINg,  

blOwER ANd wIRINg 

1. Remove metal grease filters.

2.  Remove charcoal filters  

(if present).

TO ACCESS ThE uSER INTERFACE ASSEMblY

Remove 2 thumbscrews holding the control bracket plate. Remove 

the plate.

Remove 2 screws that 

secure the control behind 

the front glass.

Remove the interface 

assembly by unplugging 

the ribbon harness 

connector from the  

control PCB.

IMPORTANT: Before 

replacing the assembly, 

check the operation of the 

hood by plugging the new 

User Interface Assembly  

cable into connector  

CNII on the Control PCB.  

If the unit does not work,  

replace the control board  

first and then recheck  

whether the existing user  

interface assembly is OK.
Reverse these steps to  

reinstall the User Interface  

Assembly.

TO REPlACE A hAlOgEN lAMP  

ASSEMblY

Reach inside the chassis and press  

with fingers against the metal spring  

clips. Pull the lamp assembly out  

and disconnect the wire connector.

TO ACCESS ElECTRICAl COMPONENTS:

1. Remove two screws from top duct cover at ceiling and slide top 

cover down.

2. Lift and remove both duct covers. Set covers aside.

uSER INTERFACE ASSEMblY

The replacement assembly has three PCBs mounted in a plastic  

enclosure with eight push buttons and a ribbon cable with ferrite 

bead looped through the other end of the cable ribbon. It consists  

of the Fan Touch Control PCB, Lamp Touch Control PCB and the  

Display PCB.

     CAuTION: 

Components are electrically hOT on 

the electronic control when voltage is connected to the hood.

Junction box

Service  

manual

Bulb

Tab

Use gloves 

or cloth

Receptacle

use a new 120-volt, 

25-watt halogen lamp 

with a g-9 base. do 

not substitute other 

lamps.

Replace lens cover. Make sure the tabs are inserted into the slots.

Removable inner 

lamp lens cover

Outer trim ring 

(lamp assembly) 

Do not remove

Use a small flat-blade screwdriver to remove the lamp lens cover.

Spring 

clips

Remove 2 thumbscrews

Fan motor

Filter microswitch

Remove screw

Remove screw

05-09 JR

PCB

Capacitor

User 

Interface 

Assembly

Reviews: