Page 1: ...PNSF39Z01 GE Appliances GE Answer Center 800 626 2000 Owner s Manual Part No 215C1002P003 Pub No 49 5801 Water Softening System 7178943...

Page 2: ...ou use your water system That s important because your new system will be part of your family for many years And we hope you will be part of ours for a long time to come We thank you for buying GE We...

Page 3: ...in just a few minutes This Owner s Manual can tell you how You ll find many answers to common problems here If you review our chart of Troubleshooting Tips first you may not need to call for service a...

Page 4: ...rks department for plumbing and electrical codes You must follow these guidelines Use care when handling the water softening system Do not turn upside down drop or set on sharp protrusions Water softe...

Page 5: ...water over 100 F Do not install in direct sunlight Excessive sun heat may cause distortion or other damage to non metallic parts Properly ground to conform with all governing codes and ordinances Fol...

Page 6: ...nominal size in dia x height 10 x 35 Service flow rate gpm See rating label located on the softener Water supply maximum hardness gpg 110 Water supply maximum clear water iron ppm 8 Water pressure li...

Page 7: ...This is called ion exchanging It is much like a magnet attracting and holding metals Water without the hardness minerals soft water flows from the water softening system and to the house pipes After...

Page 8: ...closes Water continues to flow in the same path as during brining except for the discontinued brine flow Hardness minerals and brine flush from the resin tank to the drain Backwash During backwash wat...

Page 9: ...for timer programming One beep signals a change in the timer display Repeated beeps mean the timer will not accept a change from the button you have pressed and you should use another button To set t...

Page 10: ...press SET to apply You can get the grains per gallon gpg hardness of your water supply from a water analysis laboratory or call and ask your local water department if you are on a municipal supply 2...

Page 11: ...OLD button RECHARGE TONIGHT flashes in the time display area A regeneration will occur at the next preset regeneration start time If you decide to cancel this regeneration touch the same button once m...

Page 12: ...r code is displayed the TOUCH or HOLD and DATA buttons remain operable so you can perform the Manually Initiated Electronic Diagnostics If electrical power to the water softening system is interrupted...

Page 13: ...he water softening system GALLONS TODAY Each day beginning at midnight the timer keeps a running count of the total gallons of water that have passed through the water softening system AVG DAILY GALLO...

Page 14: ...n the storage tank Is the plumbing bypass valve directing water for soft water service Is the valve drain hose open to the drain not elevated too high and unobstructed If you do not find a problem wit...

Page 15: ...r OPEN A NEARBY SOFT WATER FAUCET 000 to 199 continual repeats display for each gallon of water passing through the meter If you don t get a reading in the display with faucet open pull the sensor fro...

Page 16: ...shows the total number of recharges top since the timer was connected to electrical power The number of days since the timer was connected to electrical power is shown in the bottom part of the displa...

Page 17: ...ining a flashlight into the brinewell and observing a noticeable drop in the liquid level NOTE Be sure a salt bridge is not preventing water with salt contact If the water softening system does not dr...

Page 18: ...ol regeneration frequency based on water usage readings from the water meter It provides the most economical operation You can set a maximum time in days between regenerations For example no more than...

Page 19: ...s 1 2 4 5 6 and 8 Gallons or Liters Measure All water flow rate and usage displays are in gallons with the default setting If reset to the same displays are shown in liters Use steps 1 2 4 6 7 and 8 t...

Page 20: ...to help the water softening system handle iron in the water supply Although this additive may help to keep the water softening system resin clean it may also release corrosive fumes that weaken and s...

Page 21: ...brine from the salt storage area to the resin tank during regeneration If it becomes plugged with sand dirt etc the water softening system will not work and you will get hard water To get to the nozz...

Page 22: ...roblem has been corrected Water softening system Meter turbine stuck Call for service not regenerating Sensor wire corroded Call for service Faceplate defective Call for service No power to unit Check...

Page 23: ...conditions and correct as needed With the power supply Fuse blown or circuit restored observe the faceplate breaker popped on circuit time display and read Program to electrical outlet Memory section...

Page 24: ...softening system during water softening is regenerating system regenerations because the water heater will refill with hard water See Automatic Hard Water Bypass During Regneration section Timer hard...

Page 25: ...onsumer Product Ownership Registration Important Mail Today GE Appliances Place in an envelope and mail to General Electric Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4...

Page 26: ...ontact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains informa tion you will need should you require service Our...

Page 27: ...ng this full original purchase one year warranty GE will also provide free of charge all labor and in home service to replace the defective part Three Years The electronic monitor if it fails due to a...