GE
Security
60-924-3-XT-2WTTS Simon XT
Touch Screen Installation Sheet
Description
The Simon XT Talking Touch Screen (model 60-924-3-XT-2WTTS)
features a color 3.5 inch LCD screen with a graphical user
interface designed to control basic functionality of the Simon XT
(v1.3 or later) control panel. Up to four touch screens can be
learned (programmed) into each Simon XT panel.
The touch screen provides a convenient option for the following
system operations:
•
Arm the system (doors, windows, and motion sensors).
•
Disarm the system.
•
Activate a panic alarm to call the central monitoring station in
a nonmedical emergency.
•
Check system status.
•
Turn system controlled lights on or off (depending on your
system configuration).
•
Hear voice feedback of the status of the Simon XT control
panel.
Installation
Use the following guidelines when adding this touch screen to the
Simon XT system:
•
Program (learn) the touch screen into the control panel as a
sensor.
•
Program touch screens using sensor groups 00, 01, 04, 05, 06,
or 07.
•
The touch screen will work best if mounted greater than 3 ft.
(1.0 m) from the Simon XT panel.
•
Avoid mounting the touch screen directly behind the Simon
XT panel on the opposite side of the wall.
•
Always do a sensor test before attaching the touch screen to
the wall.
•
Do not wrap the antenna into the backplate. Follow the
instructions to install the antenna into the wall.
To program (learn) the touch screen into the panel:
1. Press the down arrow button on the panel and scroll to
System Programming.
2. Press OK.
The panel displays
Enter Code
.
3. Enter the installer access code and press OK.
4. Scroll to Sensors and press OK.
5. When the panel displays
Learn Sensor,
press OK.
The panel blinks
Trip Sensor nn
(where nn is the next
available zone number. You can enter a different zone
number if desired.
6. On the touch screen:
A. Press the Settings button.
B. Press the Down arrow until the Clear and Enroll button
appears.
C. Press the Clear and Enroll button.
7. You can now program the group number (00, 01, 04, 05, 06,
or 07) and press OK.
8. Press the Up or Down arrow to select a name for the touch
screen and press OK. (Refer to the Simon XT installation
instructions for programming sensor text.)
You can select something simple, such as “Touch Pad”, or use
additional descriptors, such as “Bedroom Touch Pad”.
Note:
During install mode, it is normal for the four blue LEDs
on the panel to blink as this indicates the panel is updating
the touch screen status. Do not leave program mode if you
have modified sensor information or are downloading a
company logo while the four blue arming LEDs on the panel
are blinking (this may disrupt configuration).
9. To verify that the touch screen is programmed (learned),
press the Status button on the panel repeatedly to leave
system programming and return to normal panel operation.
10. Press the Settings button on the touch screen and press the
Hear button.
The touch screen should announce the panel arming level
and status, such as
Disarmed System Okay
.
© 2010 GE Security, Inc.
1 of 4
P/N 466-2383 • REV A • ISS 02MAR10