background image

imagination at work

Power Supply Features

(GEPS24-180U)

•  Supports Tetra PowerStrip DS, Tetra Contour  

 

 

  and Tetra Contour LS LED lighting systems
•  Class 2 wiring per NEC Article 725 (SELV equivalent)
•  Damp location rated
•  IP66 rated: separate enclosure required

Power Supply Installation

Connect the supply wire 
that is attached to the Tetra 
LED System to the red (+) 
and black (-) output wires 
of the power supply as 
outlined in the “

Electrical 

Connections” section 
of your LED system’s 
Installation Instructions.

2

Mount power supply and 
remove junction box cover.
Carefully remove knockout 
for AC line input wires. Install 
appropriate electrical fittings 
in the knockout holes for 
wire protection. 

Connect the AC line to 
the black (line) and white 
(neutral) input wires of 
the power supply using 
18-14 AWG (0.82-2.08 mm

2

twist-on wire connectors. 
Ground power supply by 
connecting green wire with 
yellow stripe to grounding 
screw. Replace junction box 
cover. 

1

Tetra

®

 

LED Systems Power Supply

White (neutral)

Black (line)

Green with 
yellow 
stripe 
(ground)

AC line

3

BEFORE YOU BEGIN

Read these instructions completely and carefully.

WARNING/AVERTISSMENT

Risk of electrical shock. Disconnect power before servicing or installing product. Risk of fire. Do not interconnect output terminations.

Risque de choc électrique. Couper l’alimentation avant le dépannage ou avant l’installation du produit. Risque du feu. Risques 

d’incendie ou de choc lectriques. Ne pas interconnecter les bornes de sortie.

GE

Lighting Solutions

Installation Guide

24

Volt

To Tetra LED System

Output wires