imagination at work
Power Supply Features
(GEPS24-180U)
• Supports Tetra PowerStrip DS, Tetra Contour
and Tetra Contour LS LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV equivalent)
• Damp location rated
• IP66 rated: separate enclosure required
Power Supply Installation
Connect the supply wire
that is attached to the Tetra
LED System to the red (+)
and black (-) output wires
of the power supply as
outlined in the “
Electrical
Connections” section
of your LED system’s
Installation Instructions.
2
Mount power supply and
remove junction box cover.
Carefully remove knockout
for AC line input wires. Install
appropriate electrical fittings
in the knockout holes for
wire protection.
Connect the AC line to
the black (line) and white
(neutral) input wires of
the power supply using
18-14 AWG (0.82-2.08 mm
2
)
twist-on wire connectors.
Ground power supply by
connecting green wire with
yellow stripe to grounding
screw. Replace junction box
cover.
1
Tetra
®
LED Systems Power Supply
White (neutral)
Black (line)
Green with
yellow
stripe
(ground)
AC line
3
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSMENT
Risk of electrical shock. Disconnect power before servicing or installing product. Risk of fire. Do not interconnect output terminations.
Risque de choc électrique. Couper l’alimentation avant le dépannage ou avant l’installation du produit. Risque du feu. Risques
d’incendie ou de choc lectriques. Ne pas interconnecter les bornes de sortie.
GE
Lighting Solutions
Installation Guide
24
Volt
To Tetra LED System
Output wires