background image

Installation

 

and Maintenance Manual

INSTALLERS: PLEASE READ ALL INSTRUCTIONS BEFORE 
INSTALLING AND USING THIS SYSTEM.

IT  IS  RECOMMENDED  TO  WAIT  UNTIL  THE  ENTIRE 
SYSTEM  IS  PRESSURIZED  (INCLUDING  STORAGE TANK  & 
FAUCET)  AND  RE-CHECK  FOR  ANY  LEAKS  BEFORE 
LEAVING INSTALLATION SITE.

IT  IS  NORMAL  FOR  SOME  BLACK  CARBON  FINES  TO 
APPEAR  IN  THE  WATER  WHEN  EMPTYING  THE  FIRST  2 
TANKS  OF  WATER.  THE  FIRST  2  TANKS  OF  WATER 
PRODUCED SHOULD BE EMPTIED AND NOT USED.

Reverse Osmosis Water Filtration System

RO-TW

FILTER CARTRIDGE CONFIGURATION MAY BE SUBJECT TO CHANGE. 

Summary of Contents for RO-TW

Page 1: ...ESSURIZED INCLUDING STORAGE TANK FAUCET AND RE CHECK FOR ANY LEAKS BEFORE LEAVING INSTALLATION SITE IT IS NORMAL FOR SOME BLACK CARBON FINES TO APPEAR IN THE WATER WHEN EMPTYING THE FIRST 2 TANKS OF WATER THE FIRST 2 TANKS OF WATER PRODUCED SHOULD BE EMPTIED AND NOT USED Reverse Osmosis Water Filtration System RO TW FILTER CARTRIDGE CONFIGURATION MAY BE SUBJECT TO CHANGE ...

Page 2: ...ling the Faucet Installing the Feed Water Diverter Valve Installing The Waste Water Saddle Installing the Unit Installing Tubing Into Fittings Installing Tubing Connections Sanitize System Flush System and Check Operation Filter Change Schedule Trouble Shooting Spare Parts List Flow Diagrams Operation Specifications Warranty 1 1 2 3 5 6 7 7 8 10 10 11 12 13 14 14 15 16 17 18 19 20 ...

Page 3: ... Schedule Your filters require changing on a regular basis Instructions to change them are on page 15 The schedule below is the minimum recommendation Depending on your water conditions the filters may need to be changed more often 1 TW PP10 TW GAC10 TW BC10 GP 75G Q TW COC10 Every 6 12 months Every 6 12 months Every 6 12 months Every 15 24 months Every 12 months Your system contains filters which mu...

Page 4: ...mp models work on inlet water pressures of 15 psi minimum to 60 psi maximum If your house water pressure is over the maximum install a pressure reducing valve in the water supply line to the filter system Do not install the system outside or in extreme hot or cold temperatures Temperature of the water supply to the R O system must be between 40 110 F 5 45 C Do not install on hot water Tools Needed ...

Page 5: ...basement or other location depending on available space It is recommended the system be installed in as close a proximity to the faucet to ensure optimal system flow rate If you have a water dispenser and or ice maker in your fridge your RO system can be installed to provide the feed water for these features but you should consult your fridge owners manual for further information ...

Page 6: ...required RO unit may be mounted on either side of the sink in a cabinet or heated basement with nearby access to a potable cold line and a drain In the cabinet Mounted On the wall On the cabinet 4 NOTE All components and tubing should be located in an area not exposed to freezing temperatures or direct sunlight Drain connection is accomplished using a waste water saddle valve which is designed to ...

Page 7: ... 3 5 4 The following components make up your Reverse Osmosis 1 Pre PP Sediment removes larger particles such as sand silt and rust Drinking Water System 2 Pre removes chlorine in the feed water to protect Granular Carbon the reverse osmosis membrane 3 Block Carbon Pre further removes chlorine in the feed water to protect the reverse osmosis membrane ...

Page 8: ... final polish to provide great tasting drinking water 6 Storage Tank 2 8 Gal holds filtered water ready for use 7 Feed Water Diverter Valve is connected to the cold water line to supply water to the RO system 8 Faucet Standard used to dispense RO water when needed Optional air gap and designer faucets are available 1 Cartridge Filters 2 Faucet 3 Feed Water Diverter Valve 4 Waste Water Saddle 5 Unit ...

Page 9: ...RO storage tank comes with a 3 8 shut off valve that must be installed 1 Apply 5 6 wraps of Teflon thread sealant tape to the male thread on the RO storage tank 2 Install the shut off valve and tighten until the gasket is compressed 3 Connect 3 8 white tube Installing the Filters Remove the protective wrap from the filter cartridge Apply NSF certified silicon grease provided liberally on the filter o ...

Page 10: ...has a hole that can accommodate the RO faucet no drilling is required Proceed with mounting the faucet NOTES While there is a gasket that seals against the shut off valve it is recommended to still use Teflon tape on the tank threads to insure a good seal is achieved It is also recommended to check for any leaks after the system has had time to produce water and pressurize inside the storage tank F...

Page 11: ...et mounting hole if sprayer or second hole is not used check below to make sure the drill does not interfere with anything below the sink Center punch a small indent at the desired faucet location 2 flat surface is required not exceeding 1 1 4 in thickness Drill the 1 8 pilot hole Drill the hole for the faucet shank to fit through Clean up sharp edges Mounting the Faucet 9 Porcelain Enamel Ceramic o...

Page 12: ... The Waste Water Saddle Caution The water supply to your unit MUST be from COLD WATER LINE Connect with water system Figure 2 Feed Water Diverter Valve Connect with normal tap water Connect with source water The feed water diverter Valve is designed for use with 3 8 to 1 2 OD soft copper supply tubing Turn off cold water valve from under sink or main water line valve for whole house Wrap threads o...

Page 13: ...k to change the filters Installing the Unit Never install a waste water saddle close to the outlet of a garbage disposal or plugging of the RO drain line may result Refer to location in Figure 3 1 Position half of the saddle with quick connect fitting at selected location and mark for the opening 2 Drill hole at mark through one side of pipe Position both halves of the saddle on drain pipe so quick ...

Page 14: ...ic tubing we recommend the use of a tube insert Push the tube into the fitting and up to the tube stop Install the water tube 1 Locate the unit in the desired position Make sure it is at least 3 off the floor Level it and mark the location of mounting screws 2 Install the screws Leave 1 4 of the screw head out from the wall 3 Install the mounting bracket slots over the screws and hang the unit NOTE ...

Page 15: ...that the system can easily be pulled out from the cabinet for easy filter changes 1 Connect 3 8 white tube from faucet to RO unit 2 Connect 3 8 white tube from tank to RO unit 3 Connect 1 4 white tube from supply valve to RO unit 4 Connect 1 4 red tube from drain valve to RO unit 5 Check all connections to be sure they are secure 6 Turn on feed water diverter valve and check for leaks turn off and ...

Page 16: ...dle and allow tank to completely drain Do not use this water When tank is empty faucet will steadily drip This is the rate the R O system processes water 2 Close faucet and reinspect system for leaks 3 Allow system to process water for approximately four hours at which point tank will be practically full 4 Open faucet again and allow tank to empty for a second time Do not use this water 5 Wait ano...

Page 17: ...ions Change Membrane Procedure Disposable Filters Change Schedule TW PP10 TW GAC10 TW BC10 GP 75G Q TW COC10 Every 6 12 months Every 6 12 months Every 6 12 months Every 15 24 months Every 12 months 1 Turn off water supply by turning handle on feed water diverter valve clockwise until valve is fully closed 2 Turn storage tank valve clockwise to close 3 Open faucet to relieve pressure 4 To disconnec...

Page 18: ...1 High pressure switch not working 1 Pre filter plugged or low feed water pressure 1 Plugged drain flow restrictor 1 Post filter is exhausted 1 Tubing connections not installed properly 2 Defective tubing 1 Turn on feed water 1 Clear restriction 2 Replace pre filter cartridge s 3 Open valve or unclog 4 Clear or replace Flow Restrictor 1 Check source water supply 2 Turn on power supply 3 Replace 1 Repl...

Page 19: ... fitting DC 002 9 680577668591 Quick fitting DC 007 10 680577668614 Post carbon filter TW COC10 11 680577668607 Carbon block filter TW BC10 12 680577668621 Granular carbon filter TW GAC10 13 680577668638 PP sediment filter TW PP10 14 680577668478 Water faucet K6 3 8 15 680577668485 Faucet connector DC 019 3 8 x7 16 16 680577668492 Feed water diverter valve DC BV 1 2 x1 2 x1 4 17 680577668508 Tank ball v...

Page 20: ...18 RO TW No Pump 2 8 GAL Tank PP SEDIMENT BLOCK CARBON GRANULAR CARBON SHUT OFF VALVE Membrane CHECK VALVE FLOW CONTROLLER To Drain Inlet POST CARBON FAUCET Flow Diagrams ...

Page 21: ...ED NON CHLORINATED FEED WATER PRESSURE R0 TW 40 100 PSI TEMPERATE 40 110 F 5 45 C PH 3 0 11 0 MAX TDS 1000 PPM TURBIDITY 1 0 NTU MAX SDI 4 0 HARDNESS 5 GPG IRON 0 1 MANGANSESE 0 05 HYDROGREN SULFIDE 0 00 Operation Specifications ...

Page 22: ...eekpure s obligation to the customer under these warranties shall be limited at its option to replacement items covered by these warranties Prior to return of covered Items the customer must obtain a return goods authorization number from Geekpure and at Geekpure s option return the item freight prepaid at the customer s expense Any covered item replaced under these warranties will be returned pre...

Page 23: ...www geekpure cc ...

Reviews: