background image

 

IN/OUT Wireless Thermometer 

Item No.T208688 

User Manual 

Thank you for purchasing T208688 IN/OUT Wireless thermometer.

Please take a moment to read this guide and store it for future reference

Controls and displays:

1.Time display

2.Calendar

3.In/Outdoor max/min temperature and humidity 

4.Outdoor temperature

5.Indoor temperature

6.Display low battery indicator

7.Alarm icon

8.Channel for external sensor

9.Outdoor sensor signal strength

10.Outdoor humidity

11.Indoor humidity

12.Tendency indoor humidity

13.SET button

14.DOWN/MEM button

15.UP/C/F button

16.ALARM button

17.CH button

18.SNZ/LIGHT button

19.Wall mount hole

20.Battery Compartment 2xAAA (batteries not included)

21.Stand bracket

22.Wireless signal indicator(Flashes when data is being sent to the

display unit)

23.Integrated hang hole

24.Compartment 2xAAA batteries (batteries not included)

25.TX channel selector, select external sensor channel (Maximum 3 

channels available)

Package Contents:

1. Display Unit

2. Outdoor Sensor

3. Instructions Manual

Installing or Replacing Batteries:

We recommend using high quality batteries for the best product 

performance. Heavy duty or rechargeable batteries are not 

recommended. The outdoor sensor requires lithium batteries in low 

temperature conditions. Cold temperatures can cause alkaline 

batteries to function improperly.Do not mix old and new batteries. Do 

not mix alkaline, standard, and/or rechargeable batteries.

Default settings:

1.Default time: 12:00(US) 0:00(EU)

2. Default date: 01/01 (Year: 2020, date form: M/D[US],date form: 

D/M[EU])

3. Default temperature: °F(US)/ °C(EU)

4. Default alarm: AM 6:00, default snooze time: 5min.

The LCD display fully for 3 seconds when changing new battery or 

resetting, then with a sound BI into the normal state, after testing 

temperature, receiving RF for 3 minutes.

Display / Keys Details:

There are totally 6 keys for the alarm clock, they are included: SET, 

DOWN/MEM, UP/C/F, ALARM,CH ,SNZ/LIGHT.

1.SET buttons:

a. Press and hold for 3 seconds during normal mode to enter setting 

mode.

b. Press SET button during normal mode to enter alarm mode.

2. DOWN button:

a. Decrease the current setting value.

b. In normal display mode, press this button to check the max/min 

temperature and humidity values.

c.Press and hold this button to clear the max/min temperature and 

humidity values.

3.UP button:

a. Increase the current setting value.

b. In normal display mode, press this button to switch between 

Celsius and Fahrenheit.

4.ALARM button:

Open and close the alarm.

5.CH button

a Press this button to select the channel.

b. In normal display mode, press and hold to search RF.

6.SNZ/LIGHT button

a. Press this button to open backlight for 10 seconds .

b. Press to activate the snooze function when alarming.

Manually Setting the Time, Date & Units:

Press and hold down the "SET" button for 3 seconds the 12/24 hour 

mode starts to flash, use “UP/C/F” and “DOWN/MEM” buttons to set 

the correct 12/24 hour mode.

Press "SET" button to confirm your setting, the hour display starts to 

flash, use “UP/C/F” or “DOWN/MEM” buttons to set the correct hour.

Press "SET" button to confirm your setting, the minute display starts 

to flash, use “UP/C/F” or “DOWN/MEM” buttons to set the correct minute.

Press "SET" button to confirm your setting, the year display starts to 

flash, use “UP/C/F” or “DOWN/MEM” buttons to set the correct year.

Press "SET" button to confirm your setting, the month display starts to 

flash, use “UP/C/F” or “DOWN/MEM” buttons to set the correct month.

Press "SET" button to confirm your setting, the date display starts to 

flash, use “UP/C/F” or “DOWN/MEM” buttons to set the correct date.

NOTE:

 

You will automatically exit settings mode if no buttons 

are pressed for 20 seconds. Enter settings mode again at any 

time by pressing and holding the SET button for 3 seconds. 

Under normal mode, press SET button to enter alarm mode.

Setting the Alarm:

a. Press 

SET

 button to enter alarm mode, press and hold the 

SET

 

button for about 3 seconds to set the alarm time. The alarm hour will 

begin blinking on the display where the clock time is usually shown.

b. To adjust the alarm hour, press the “UP/C/F” or “DOWN/MEM” 

buttons (press and hold to fast adjust). 

c. To adjust the alarm minute, press the “UP/C/F” or “DOWN/MEM” 

button (press and hold to fast adjust). 

d.Press 

ALARM

 button to open and close alarm setting.The “       ” 

symbol should show next to the clock display when alarm is set to ON.

e. When the alarm is in operation it will begin beeping with

one short beep and continue with many short beeps if the alarm 

rings longer than 20 seconds. You can snooze the

alarm for 5 minutes by pressing the SNZ/LIGHT button.

Indoor / outdoor temperature and humidity:

1. Indoor temperature -9°C ~50°C , display LL.L when below

-9°C and display HH.H when higher than 50°C.

2. Outdoor temperature -40°C ~ 70°C, display LL.L when below 

-40°C and display HH.H when higher than 70°C.

3. Indoor and outdoor humidity range: 20%-95%

4. When alarm ringing, temperature and humidity test will be stopped.

Accuracy:

1. Temperature accuracy:

-40°C ~ -20°C: ± 4°C

-20°C ~ 0°C: ± 2°C

0°C ~ +50°C: ±1°C

Note: when the temperature in 50°C ~ 70°C range, the 

temperature is only for reference.

2. Humidity accuracy: +/- 5 % RH (@25°C , 30%RH to 50%RH); 

      +/- 10 % RH (@25°C , 20%RH to 29%RH, 51%RH to 95%RH)

BackLight:

Press the SNZ / LIGHT button to active the backlight for 5 seconds.

Low Battery Indicator:

If the low battery indicator is displayed on the LCD for either the 

outdoor sensor or the display unit, immediately change the batteries 

to prevent disruptions in communications of the devices.

Setting the Channel:

  

Setting the channel connection between the display unit and 

outdoor sensor:

a. To change the channel on the display unit between 1, 2, 3 &1-3 

sequential display, press the “CH” button. The channel setting will 

display on the above of the outdoor temperature.

b. To change the channel option on the outdoor sensor open the 