CONFIGURATION & WIRING OF PERIPHERALS

 

Summary of Contents for GEOLOGGER G8 PLUS

Page 1: ...1 DATA LOGGER GEOLOGGER G8 PLUS A D V A C E D I N S T R U C T I O N M A N U A L CONFIGURATION WIRING OF PERIPHERALS...

Page 2: ...inputs 11 Wiring options to analogue SmartMux 12 Grounding the VW sensor shield wire to analogue SmartMux 13 Grounding the G8 and or Remote SmartMux 14 G8 to analogue SmartMux system configurations 15...

Page 3: ...to the measurement control module Power Supplies A power supply provides regulated power to the logger and sensors 12 volt DC fed either by 220 volt mains adaptor and charger with 12 Volt DC battery b...

Page 4: ...UT OUTPUT RS232a ANALOGUE INPUT OUTPUT USB PORT FOR DATA BACKUP DIGITAL IN 1 LOCAL DIGITAL DEVICE TO G8 INPUT DIGITAL IN 0 LOCAL DIGITAL DEVICE TO G8 INPUT ANALOG IN 0 LOCAL ANALOGUE DEVICE TO G8 INPU...

Page 5: ...12V A separate module is required for radio outputs 1 120 Termination Resistor RS485a 1 RS485b 1 Digital Sensor Digital Bus Analogue Mux Digital Mux Tx Rx COM Radio 5V 12V Siren Horn Light 12V COM Pow...

Page 6: ...6 G8 Module Connections top side Trigger Pulse Counter Analogue Input 0 0 10V 0 3V 4 20mA COM USB Port for data backup SGLC mv V Channel can receive single ended voltage signal...

Page 7: ...7 Mains Powered G8 Enclosure Schematic Wiring Diagram Battery Fuse EMC filter 240V 12V Transformer Fuse Modem Radio Antenna MAINS IN SENSORS IN G8 Module SmartMux...

Page 8: ...our system design 1 Not used always have DOWN 2 120 Termination Resistor only have UP when at the end of the string 1 RS232 RS485 Switch DOWN for RS485 2 Not for customer use always have DOWN The setu...

Page 9: ...to the G8 Rebooting a SmartMux Reboot Mode Rebooting the SmartMux will cause it to lose it s memory and it will then be able to communicate with a new G8 1 In the middle block of dipswitches push all...

Page 10: ...nnel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 16 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 16 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 C...

Page 11: ...11 mV V Sensors VW Temp Sensors 4 20mA Sensors TOP BOTTOM RS232 For Radio Module EXTERNAL POWER SUPPLY G8 RS485a b Analogue Smart Mux inputs V In GND...

Page 12: ...3 4 Channel 3 Sensor 1 2 3 4 Channel 4 Sensor 1 2 3 4 R232 TxD RxD GND V Out Channel 13 Sensor 1 2 3 4 Channel 14 Sensor 1 2 3 4 Channel 15 Sensor 1 2 3 4 Channel 16 Sensor 1 2 3 4 4 20mA output Uniax...

Page 13: ...he shield wires from the sensors have not been connected to the multiplexer Grounding the VW Sensor Shield Wires to the Analogue Smart Mux Reduce the effects of electronic interference by grounding th...

Page 14: ...has it s own earth cable Common ground connects any mux to the G8 BATTERY G8 M2 M3 M1 Twisted pair provides A B signals whilst cancelling out noise Signal ground is therefore not required The return o...

Page 15: ...nd RESISTOR OFF Mux at the end of the string RESISTOR ON G8 at the beginning of the string RESISTOR ON Mux at the end of the string RESISTOR ON Mux at the end of the string RESISTOR ON RESISTOR OFF RE...

Page 16: ...e 1 RS485 Typical Wiring between G8 and Analogue Smart Mux Configuration G8 at the start of the chain 1 2 3 4 5 6 7 8 1 2 1 2 1 2 3 4 5 6 7 8 1 2 1 2 RS485 COM B A 12V RS485 COM B 12V A REMOTE SMARTMU...

Page 17: ...al Wiring between G8 and Analogue Remote Smart Mux Configuration G8 in the middle of a chain 1 2 3 4 5 6 7 8 1 2 1 2 1 2 3 4 5 6 7 8 1 2 1 2 RS485 COM B A 12V RS485 COM B 12V A REMOTE SMARTMUX yyyyy R...

Page 18: ...r to change an analogue signal into a digital signal You would then connect to the Mux using the RS485 connector block The RS232 connection on the mux is used for radio connections RS232 RS485 Signal...

Page 19: ...to connect the modem to the G8 Antenna Required for GSM connection The modem will not work without this or another SMA antenna connected Mains supply 2 pin plug provided The Router LAN Port Plug in y...

Page 20: ...owering the router When installed in an enclosure like this the router can be powered by the G8 itself using the MOD1 2 connectors When powered AND connected the router lights will look like this with...

Page 21: ...and Sharing Centre go to the properties of the Local Connection sometimes you must go to change adapter settings 2 Select properties You will need an administrator username and password for this 3 Do...

Page 22: ...password stated on the label Router Modem Setup Configuring the router TCP IP Forwarding The IP address must be that of the G8 Any message coming to the stated ports will be directed to this IP addres...

Page 23: ...ssible except for local acquisitions Type the public IP address of the SIM card into the web browser preset username admin password 1234 these can be changed within the G8 setup The webserver home pag...

Page 24: ...aded files to be saved G8 connection status Disconnect Cancel Refresh Download status Shows if downloads are queued successful or failed General Host SIM IP address User and Password is the same as yo...

Page 25: ...N ALWAYS ON MODULE 2 SUPPLY AS PER MODULE 1 SUPPLY RADIO MODULE ANALOGUE INPUTS ADC0 NONE 4 20mA 0 3V 0 10V ADC1 AS PER ADC0 DIGITAL INPUTS DIG0 NONE TRIGGER PULSE COUNTER FREQUENCY INPUT DIG1 AS PER...

Page 26: ...IG MANUAL LAN CONFIG DHCP SD CARD EXPLORER A MUMS MUX SYSTEM 1 SYS CAL CONF DATA DMUX IPTM This is the IP address of the logger itself These are the same folders that you can see on an FTP Client You...

Page 27: ...ME LEAVE ORIGINAL RENAME FILES CONFIGURATION G8 LOGGER SETUP ADVANCED TOOLS SYSTEM BACKUP DATA BACKUP BACKUP RATE USB BACKUP POWER MODE FULL FUNCTIONS MIDNIGHT RESET MODULE 1 SUPPLY OFF LOW POWER MODE...

Page 28: ...IT DELETE LIMIT DELETE ALL LIMITS SENDER MAIL RECEIVERS MAILS NOTIFICATION LIST VIEW EDIT APPEND NEW ERASE ALL WARNING LIST VIEW EDIT APPEND NEW ERASE ALL ALARM LIST VIEW EDIT APPEND NEW ERASE ALL ALA...

Page 29: ...LIST DELETE RADIO LIST REBOOT CALIBRATION BATTERY VOLTAGE TEMPERATURE TASKS USAGE CONFIGURATION DEVICES CONFIG GMUX CONFIGURATION VIEW MUX NEW EDIT MUX RS485a OFF ON DURING ACQ RS485b OFF ON DURING AC...

Page 30: ...CQUISITION APPEND DATA ACQUISITION LOCAL CHANNELS LOCAL ACQUISITION GDATA LOCAL ACQUISITION MUX LOCAL ACQUISITION MUMS LOCAL ACQUISITION IPTM LOCAL ACQUISITION STOP START ACQUISITION Read battery volt...