background image

PVT READING KIT FOR PC Manual

2015-02-25

USERS MANUAL

PVT READING KIT FOR PC

with

GEOTECH PVTLog

for programming of and data collection from

GEOTECH PVT PIEZOMETERS

Ingenjörsfirman Geotech AB
Datavägen 53
SE-436 32 ASKIM (Göteborg)
Sweden
Ph: +46 - 31 28 99 20
Fax:+46 -31 68 16 39

E-mail: info@geotech.se
www.geotech.eu

Published date: 2015-02-25

Summary of Contents for 19656

Page 1: ...FOR PC with GEOTECH PVTLog for programming of and data collection from GEOTECH PVT PIEZOMETERS Ingenj rsfirman Geotech AB Datav gen 53 SE 436 32 ASKIM G teborg Sweden Ph 46 31 28 99 20 Fax 46 31 68 1...

Page 2: ...PVT READING KIT FOR PC Manual 2015 02 25...

Page 3: ...gramming software 2 2 3 Additional product information 2 2 4 Intended use 2 2 5 System components overview 3 2 6 3 Read out kit for PC 5 Installation 5 3 1 Main page 5 3 2 Piezometer reading 5 3 3 Fil...

Page 4: ......

Page 5: ...opy can always be ordered from Ingenj rsfirman Geotech AB Content 1 1 1 The information in this publication is on the basis of information that was available at the time that the publication was writt...

Page 6: ...be sourced locally by the customer Interface 2 2 Connect the interface to a USB outlet of your computer and use the two crocodile clips for connection to the piezometer PVTLog read out and programming...

Page 7: ...irman Ge otech AB Medium for software deliv ery may change without notice Included in 19656 above PVT Interface USB USB crocodile clip inter face Compatible equipment 10591 Piezometer with memory 25 m...

Page 8: ...er tip Stainless steel Filter tip closed type with membrane Stainless steel 24560 Filter tip plastic Filter tip closed type with membrane Plastic On re quest Geotech depth registration system Geotech...

Page 9: ...ater is not installed on your computer it will also be installed PVTLog is now ready for use Main page 3 2 When PVTLog starts for the first time some basic settings are made so therefore it will take...

Page 10: ...o synchronize with an air pressure file If you have an air pressure file and want the software to compensate the log file with the air pres sure closest in time to each piezometer reading answer Yes a...

Page 11: ...e Read Memory tab The file displayed is in spreadsheet format with formulas Press Open in Excel to see the results of the calculations values in Excel This functionality requires Microsoft Excel to be...

Page 12: ...you then press Set Logging Interval Start and stop logging by select Start Logging or Stop Logging Select Erase PVT Memory to permanently delete all recorded values in the piezometer memory Record 3...

Page 13: ...ate a new recording by pressing the New button Start recording by pressing the Start button Press the Pause button if you want to pause To resume press Start again Press Done to finish the recording S...

Page 14: ...ess Pick PVT PVX file and choose file to convert If there is an air pressures file that you want to use for compensation select Pick Air pressure file and choose file Leave the box empty if you do not...

Page 15: ...Excel 2010 or later installed on your computer Press Pick PVX File to select file and press Open in Excel to open the file in Microsoft Excel Fig 9 Open the file in Microsoft Excel In the Excel window...

Page 16: ...9920 We welcome reports on bugs and suggestions for improvement Please feel free to illustrate your issue with a screen shot or similar Trouble Shooting 4 1 The trouble shooting table below is not com...

Page 17: ...PVT READING KIT FOR PC Manual 2015 02 25 13 Trouble Shooting and Support...

Page 18: ...PVT READING KIT FOR PC Manual 2015 02 25 2015 Ingenj rsfirman Geotech AB Datav gen 53 436 32 Askim SWEDEN Phone 4631289920 Fax 4631681639 www geotech eu info geotech se...

Reviews: