Gerber P2C™ Plotters Site Requirements 

Dear Gerber P2C Plotter Customer,

Thank you for purchasing a Gerber P2C 600, 1200, or 1600 plotter.

The information in this document is extremely important because it specifies the requirements
your facility must meet in order to properly install the Gerber P2C plotter. It is also important
that you complete the Site Preparation Checklist (the last page of this document) and return it to
Gerber Service so that they can schedule the installation of your Gerber P2C plotter. Please
carefully review the information in this document and checklist so that when your Gerber P2C
plotter arrives, the installation will go smoothly and you can start printing jobs quickly and
efficiently. You must review and complete the following items described in this document to
prepare your site for the Gerber P2C plotter:

Computer requirements

Connection requirements

Customer-supplied requirements

Power requirements

Work area requirements

Environmental requirements

Shipping weight and clearance requirements

Receiving and unloading the Gerber P2C plotter

Inspecting the shipment for damage

Complete and return the Site Preparation Checklist

!

 

Computer requirements 

You can output jobs to the Gerber P2C plotters using GERBER OMEGA or other compatible
graphics software.

These requirements are minimums for OMEGA CP or CS; for best results, Gerber recommends
you to use the largest hard disk and most RAM possible. System operations such as redraw and
rendering speeds improve significantly as the computer hardware exceeds the minimum
requirements listed below. More free space allows you to work with larger image files and gives
more room to store existing jobs. Faster computers and more RAM can save significant time
during the day as you use GERBER OMEGA.

The Gerber P2C plotters can be connected to your computer using USB, serial, or parallel (P2C
1600 only) cables/ports. Depending on your chosen configuration, your computer requirements
for the number of available ports may differ. See “Connection requirements” on page 2 for
detailed information.

Summary of Contents for P2C 1200

Page 1: ...ents Work area requirements Environmental requirements Shipping weight and clearance requirements Receiving and unloading the Gerber P2C plotter Inspecting the shipment for damage Complete and return...

Page 2: ...lution with more than 256 colors is highly recommended Microsoft compatible PS 2 style bus mouse not a serial mouse Connection requirements The Gerber P2C plotters include a selection of interface cab...

Page 3: ...59 cm x 68 2 cm x 105 cm 92 lbs 42 kg P2C 1600 with stand 89 long x 29 wide x 40 high 226 cm x 74 cm x 101 cm 198 lbs 90 2 kg Environmental requirements The room in which the Gerber P2C plotter is ins...

Page 4: ...ing the Gerber P2C 1200 or 1600 plotter on a different floor than where it will be delivered you may need a professional rigger to provide assistance with the equipment Please call Gerber Service prio...

Page 5: ...he carrier s possession If the carrier holds a clear delivery receipt with no notation describing the damage and the shipment remains in your possession a long time it may be more difficult to collect...

Page 6: ...es Our goal is to have your system quickly and properly installed so that you can start using and enjoying the capabilities of your new Gerber P2C plotter This document and checklist are designed to p...

Page 7: ...AC or 220 to 240 VAC Frequency 48 62 Hz 1Hz 85 V A maximum Weight and clearance requirements I do not have a loading dock but I have a forklift to take the Gerber P2C 1600 off the carrier s truck or I...