background image

USER'S MANUAL AND OPERATING INSTRUCTIONS

READ INSTRUCTIONS CAREFULLY:

 

Read and follow all instructions. Place 

instructions in a safe place for future ref-

erence. Do not allow anyone who has 

not read these instructions to assemble, 

light, adjust or operate the heater.

PORTABLE PROPANE HEATER FOR
RECREATIONAL, 
COMMERCIAL AND 
EMERGENCY INDOOR USE
FOR US SALE EXCEPT 
MASSACHUSETTS
Patent Pending

– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any 

  other appliance.

– An LP cylinder not connected for use shall not be stored in the vicinity of this or any other 

 appliance.

– WHAT TO DO IF YOU SMELL GAS

  •  Do not try to light appliance. 

  •  Extinguish any open flame. 

  •  Shut off gas to appliance.

– Service must be performed by a qualified service agency.

This is an unvented gas-fired portable heater. It uses air (oxygen) from the area in which      

it is used.

Adequate combustion and ventilation air must be provided. Refer to page 4.

Model #

HEAT AROUND 360 

RADIANT HEATER

1

IMHA360 - Rev 03-30-2017

WARNING:

If the information in this manual is not followed exactly, a fire or 

explosion may result causing property damage, personal injury or 

loss of life.

HA1360RH

HA1360R 

HA1360BK 

HA2360R 

HA2360BK

For Manual

For Product 

Registration

Questions, problems, missing parts? Before returning to your retailer, call our customer

service department at 877-447-4768

  

8:30 a.m. –  4:30

 

pm CST, Monday – Friday

or email us at customerservice@ghpgroupinc.com

www.ghpgroupinc.com

CONSUMER:

 Retain this manual for future reference.

US

CSA 4.98 US, GAS-FIRED PORTABLE HEATERS

FOR RECREATIONAL AND COMMERCIAL USE

Summary of Contents for Dyna-Glo HEAT AROUND 360 HA1360BK

Page 1: ...Servicemustbeperformedbyaqualifiedserviceagency This is an unvented gas fired portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided Refer to page 4 Model HEAT AROUND 360 RADIANT HEATER 1 IMHA360 Rev 03 30 2017 WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property dama...

Page 2: ...rotten egg odor Do not use if leaking Any changes to this heater or its controls can be dangerous Some people pregnant women persons with heart or lung disease anemia those under the influence of alcohol those at high altitudes are more affected by carbon monoxide than others If the recreational or commercial enclosure does not have a window or roof vent that is open DO NOT USE THIS HEATER inside ...

Page 3: ...heric conditions heater may not re light When moving heater when lit or bumping heater setting it down tip over switch may shut off heater If this happens re light Operating time will vary depending on the heater setting and the supply cylinder size See chart and Cold Weather Operations section NOTE This HEATER MAY BE OPERATED WITH 1 OR 2 DISPOSABLE 1 LB PROPANE CYLINDERS OR WITH 1 REMOTE REFILLAB...

Page 4: ... any gas control which has been under water When used without adequate combustion and ventilation air this heater may give off excessive CARBON MONOXIDE an odorless poisonous gas Some people pregnant women persons with heart or lung disease anemia those under the influence of alcohol those at high altitudes are more affected by carbon monoxide than others Cylinders must be disconnected when the he...

Page 5: ...ight Do not over tighten Do not use tools to tighten Attach GHP hose end adapter No HAKITDG to fuel filter by gently turning clockwise until it is hand tight Do not overtighten Do not use tools to tighten Check for gas leaks by using a 50 soap water solution at the joint of the regulator and hose end adapter Fig 1 1 lb Cylinder Tank Installation 20 lb Tank Hose Model HAKITDG Recommended Fuel Filte...

Page 6: ...position 2 Open the access door and install the propane fuel source a Install a DOT certified 1 lb propane cylinder b Install the GHP hose connector model HAKITDG Check for gas leaks by using a 50 soap water solution at the joint of the regulator and cylinder 3 Depress the control knob and turn counter clockwise to the PILOT position The Igniter will spark each time this step is performed Repeat u...

Page 7: ... Group Inc will repair or replacethis product free of charge if it has been proven to be defective within the 1 year period and is returned at customer expense with proof of purchase to GHP Group Inc within the warranty period DISCLAIM ER This warranty does not cover any product that a has been subject to misuse or neglect b has been used in a manner inconsis tent with the warnings and instruction...

Page 8: ... can lead to a fire 1 Allow heater to thoroughly cool before performing any maintenance 2 Remove disposable 1 lb cylinder s from heater or turn OFF gas supply at remote cylinder valve and disconnect hose from heater 3 Remove wire guard from heater by gently removing the four screws attaching the wire guard 4 And then remove the 3 acorn nuts and gently remove the burner assembly exposing the burner...

Page 9: ...is turned there is a spark at ODS pilot but no ignition 1 Tank shutoff valve is closed 2 Control knob not fully pressed in while pressing ignitor button 3 Air in gas lines when installed 4 ODS pilot is clogged 5 Control knob not in PILOT position 6 Depleted gas supply propane 1 Turn on gas supply valve 2 Fully press in control knob while pressing ignitor button 3 Continue holding down control knob...

Page 10: ...e just after burner is lit or shut off 1 Metal is expanding while heating or contracting while cooling 1 This is common with most heaters If noise is excessive contact qualified service technician Heater shuts off in use ODS operates 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Open window and or door for ventilation 2 Contact local gas supplier 3 Clea...

Page 11: ...0 15 RD HA1360 15 B Access Door 7 1 HA1360 01 HA1360 01 HA1360 10 BurnerAssembly 8 N A HA360 HK HA360 HK HA360 HK Hardware Kit Includes all hardware to assemble unit 9 1 1 HA1360 21 HA1360 21 HA1360 21 HingeAssembly upper 9 2 1 HA1360 22 HA1360 22 HA1360 22 HingeAssembly lower 10 1 HA1360 08 HA1360 08 HA1360 08 LP ODS PilotAssy 11 1 HA360 08 01 HA360 08 01 HA360 08 01 Thermocouple 12 1 HAC360 1 N ...

Page 12: ... 5 1 HA360 23 HA360 23 Control Knob 6 1 HA2360 PBA RD HA2360 PBA B Plastic BaseAssembly 7 2 HA2360 15 RD HA2360 15 B Door 8 1 TT15C 07 TT15C 07 Tip Switch 9 1 2 HA2360 21 HA2360 21 Door Hinge Upper 9 2 2 HA2360 22 HA2360 22 Door Hinge Lower 10 1 HA2360 08 HA2360 08 LP ODS PilotAssy 11 1 HA360 08 01 HA360 08 01 Thermocouple 4 1 2 8 5 7 6 9 2 3 9 1 10 11 12 NEVER LEAVE THE HEATER UNATTENDED WHILE BU...

Page 13: ...entative This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO REGISTER THE WARRANTY ON YOUR HEATER PLEASE FILL OUT THIS CARD COMPLETELY AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON LINE AT www ghpgroupinc com NAME ______________________________________ PHONE __________________ EMAIL ____________________________ ADDRESS _...

Page 14: ...s SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www ghpgroupinc com GHP GHP Group Inc 6440 W Howard St Niles IL 60714 330...

Page 15: ...rtefacto Las reparaciones deben ser realizadas por una agencia de servicio calificada Este es un calefactor portátil a gas sin salida al exterior Utiliza el aire oxígeno del área en que se utiliza Se debe proporcionar cantidad adecuada de aire de combustión y ventilación Consulte la página 18 N de modelo CALEFACTOR RADIANTE HEAT AROUND 360 ADVERTENCIA Si la información de este manual no se respeta...

Page 16: ...n el calefactor o en sus controles puede ser peligroso Algunas personas embarazadas personas con enfermedades cardíacas o pulmonares anémicas las que están bajo los efectos del alcohol o las que están a alturas elevadas se ven más afectadas por el monóxido de carbono que otras Si se trata de un espacio cerrado recreativo o comercial sin ventana ni ventilación en el techo que esté abierta NO UTILIC...

Page 17: ...es posible que el calefactor no se vuelva a encender Si mueve el calefactor cuando está encendido o si al colocarlo en el suelo lo golpea es posible que el interruptor de vuelco haga que se apague el calefactor Si esto sucede vuelva a encenderlo El tiempo de funcionamiento variará según el lugar y el tamaño del cilindro Consulte el gráfico y la sección Funcionamiento en clima frío NOTA ESTE CALEFA...

Page 18: ...cione el calefactor y reemplace las piezas del sistema de control y los controles de gas que se hayan mojado Si se lo utiliza sin un flujo adecuado de aire de combustión y ventilación el calefactor puede emitir una cantidad excesiva de MONÓXIDO DE CARBONO un gas tóxico que no produce olor Algunas personas embarazadas personas con enfermedades cardíacas o pulmonares anémicas las que están bajo los ...

Page 19: ...ede ajustado No lo ajuste demasiado No utilice herramientas para ajustar Conecte el adaptador del extremo de la manguera GHP n º HAKITDG al filtro de combustible girando suavemente en sentido de las agujas del reloj hasta que quede ajustado No ajuste demasiado No utilice herramientas para ajustar Coloque una solución de agua con 50 de jabón en la junta entre el regulador y el adaptador del extremo...

Page 20: ... FUNCIONAMIENTO Y APAGADO 1 Asegúrese de que la perilla de control esté en la posición de APAGADO 2 Abra la puerta de acceso e instale la fuente de combustible propano a Instale un cilindro de gas propano de 1 lb con certificación del Departamento de Transporte DOT b Instale el conector de manguera GHP modelo n º HAKITDG Coloque una solución de agua con 50 de jabón en la junta entre el regulador y...

Page 21: ...a de compra GHP Group Inc reparará o reemplazará este producto sin cargo si se prueba que el defecto se produjo dentro del período de 1 año y el cliente devuelve el producto a GHP Group Inc junto con el comprobante de compra dentro del período de garantía y asumiendo los costos de envío DESCARGO DE RESPONSABILIDAD Esta garantía no cubre ningún producto que a se haya sometido a uso indebido o negli...

Page 22: ...ede ocasionar un incendio 1 Deje que el calefactor se enfríe completamente antes de realizar cualquier tarea de mantenimiento 2 Extraiga los cilindros de 1 lb del calefactor o cierre el suministro de gas en la válvula del cilindro remoto y desconecte la manguera del calefactor 3 Retire la rejilla de protección del calefactor extrayendo con cuidado los cuatro tornillos que sujetan la rejilla 4 Extr...

Page 23: ...ncendido Cuando se gira la perilla del dispositivo de encendido hay una chispa en el ODS piloto pero no se enciende 1 La válvula de cierre del tanque está cerrada 2 La perilla de control no se presiona completamente al pulsar el botón del dispositivo de encendido 3 Quedó aire en la tubería de gas cuando se instaló 4 El ODS piloto está obstruido 5 La perilla de control no está en la posición PILOTO...

Page 24: ...ce y corrija todas las fugas El calentador produce un ruido de chasquido inmediatamente después de encender o apagar el quemador 1 El metal se expande al calentarse y se contrae al enfriarse 1 Esto es común en la mayoría de los calefactores Si el ruido es excesivo comuníquese con un técnico capacitado El calentador se apaga cuando está en uso se activa el ODS 1 No hay suficiente aire fresco 2 La p...

Page 25: ...o de la base de plástico 6 1 HA1360 15 RD HA1360 15 RD HA1360 15 B Puerta de acceso 7 1 HA1360 01 HA1360 01 HA1360 10 Conjunto del quemador 8 N A HA360 HK HA360 HK HA360 HK Kit de tornillería para instalación incluye la tornillería para ensamblar la unidad 9 1 1 HA1360 21 HA1360 21 HA1360 21 Conjunto de bisagras superior 9 2 1 HA1360 22 HA1360 22 HA1360 22 Conjunto de bisagras inferior 10 1 HA1360...

Page 26: ...instalación 4 1 HA2360 04 HA2360 04 Rejilla de protección 5 1 HA360 23 HA360 23 Perilla de control 6 1 HA2360 PBA RD HA2360 PBA B Conjunto de la base de plástico 7 2 HA2360 15 RD HA2360 15 B Puerta 8 1 TT15C 07 TT15C 07 Interruptor de vuelco 9 1 2 HA2360 21 HA2360 21 Bisagra de la puerta superior 9 2 2 HA2360 22 HA2360 22 Bisagra de la puerta inferior 10 1 HA2360 08 HA2360 08 Conj del piloto ODS p...

Page 27: ...ITAS INCLUIDAS ENTRE OTRAS LAS GARANTÍAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN DETERMINADO EL RECURSO PROPORCIONADO EN ESTA GARANTÍA ES EXCLUSIVO Y SE OTORGA EN REEMPLAZO DE TODOS LOS OTROS RECURSOS EN NINGÚN CASO GHP GROUP INC SERÁ RESPONSABLE DE NINGÚN DAÑO INCIDENTAL O INDIRECTO Algunos estados no permiten limitaciones por el tiempo que dura una garantía implícita Por lo tanto es posible q...

Page 28: ...jeta de registro de la garantía dentro de los catorce 14 días de la fecha de compra También puede registrar la garantía por Internet en www ghpgroupinc com Complete el número de serie Conserve esta parte de la tarjeta para su constancia GUARDE ESTA TARJETA Coloque aquí el sello postal GHP Group Inc 6440 W Howard St Niles IL 60714 3302 GHP Group Inc 6440 W Howard St Niles IL 60714 3302 Tel 1 877 44...

Reviews: