1
0201EN
03/2021
M
anifold
cabinets
and
supports
P
lastic
cabinet
with
cover
r595
Installation
The cabinet is large 90 mm and its proper location must be evaluated
carefully, favoring walls that have a total thickness (including plaster and
tiles) less than 10 cm.
The cabinet must be walled up with its bottom side at 25 cm from the
finished floor for an easier laying of the distribution pipes (and to make sure
they can be slipped out in removable-pipe systems).
Horizontal installation for bar or modular manifolds
height
0
at the end of the paving
25 cm
Vertical installation for coplanar manifolds
height 0
at the end of the paving
25 cm
Description
The growing use of manifold-based distribution systems, both for heating
and domestic water distribution, provides great benefits for end users and
installers that perform ordinary management and service interventions.
However, a few issues related to the type of installation and manifold have
to be considered when choosing a flush-mount cabinet.
R595
cabinets
enable the installer to assess right away their versatility and
convenience during laying and installation while saving precious time.
They are also fit for installation of Giacomini’s complete range of manifolds
thanks to the use of the R598 special quick-connection supports (sold
separately).
Versions and product codes
.
Product code
Dimensions [mm]
Connection center distance [mm]
R595AY001
370 x 300 x 90
35
R595BY001
520 x 300 x 90
35
R595CY001
670 x 300 x 90
35
R598 supports (sold separately)
Product code
Type
R598Y003
For 3/4”x16 bar manifolds
R598Y004
For 1”x16 bar manifolds and DN25 modular manifolds
R598Y007
For modular manifolds R580CY062, R580CY063, R580CY064,
R585CY062, R585CY063, R585CY064
R598Y009
For R587 3/4” or 1” coplanar manifolds
R598
supports
are easy to install inside the cabinet with their quick-
connection system.
Once the correct position has been identified, follow the steps below:
• Place the R598 support over the twin dovetail-fit system.
• Press the support slightly to connect it.
Should it be necessary to remove the support, use a screwdriver to lift and
disconnect it.
R595