DG-15 & DG-15LD
Digital Keypad
Operation Manual
I. Specifications
DG-15
DG-15WP
12 VDC
Operating Voltage
DG-15LD
12~24 VDC
DG-15
DG-15WP
Pull in: 50 mA Holding: 10mA /12VDC
Pull in: 70 mA Holding: 40mA /12VDC
Current Draw
DG-15LD
Pull in: 100 mA Holding: 60mA /24VDC
Keypad 12 buttons (0~9,
*
,
#
)
LED Status Indication 3 LED indicators display (Red/Yellow/Green)
Input
1 contact for Request-To-Exit button
1 contact for door reed switch
Output 2 relays (Dry contacts: N.O./N.C./Com.)
Relay Strike Time 01~99 seconds or Toggle Mode (00)
Relay Electric Current 3A/120VAC , 3A/24VDC
Memory Volume
20+1 PINs (
*
01~
*
021)
Relay 1 is controlled by user
*
01~
*
20
Relay 2 is controlled by user
*
21
Sign: Relay1(
*
30); Relay2(
*
31)
EPROM
Non-volatile memory allows remaining all setting codes in the event
of total power failure.
Ambient Humidity 0%~95% (Non-condensing)
Operating Temperature -20°C~+70°C
II. Status
Indication
Green On
Power on, Stand by
Red On
Relay 1 active
LED
Yellow On
Relay 2 active
1 Beep
Valid key press
2 Beeps
Enter, exit setting mode
3 Beeps
Incorrect operation
Beep
5 Beeps
Master Code back to 12345 (Cleared settings)
III. Operation Instruction
Jumper
Setting
4or5
RESET
Master Code reset to
default value"12345"
Reset
Normal
4 or 5 digit setting
4 digit
5 digit
1. Default value: “1234” for 4 digits, “12345” for 5 digits
It’s suggested to clear all stored codes prior to new setting.
2. Master Code reset to default value”12345”:
a. Insert the jumper into 1-2 (5 beeps)
b. Master Code reset to default value
Copyright All Rights Reserved.
P-MU-DG15 Ver. I Publish:2010.08.12 Page: 1/ 3