I. Specifications 

DG-15 

DG-15WP

12 VDC 

Operating Voltage 

    DG-15LD

12~24 VDC

 

DG-15 

DG-15WP

Pull in: 50 mA  Holding: 10mA /12VDC 

Pull in: 70 mA  Holding: 40mA /12VDC 

Current Draw 

DG-15LD 

Pull in: 100 mA  Holding: 60mA /24VDC 

Keypad 12 buttons (0~9,

,

)                                    

 

LED Status Indication 3 LED indicators display (Red/Yellow/Green)                     

 

Input 

1 contact for Request-To-Exit button 
1 contact for door reed switch  

Output 2 relays (Dry contacts: N.O./N.C./Com.) 

Relay Strike Time 01~99 seconds or Toggle Mode (00) 

Relay Electric Current 3A/120VAC ,  3A/24VDC

 

Memory Volume 

20+1 PINs (

01~

021) 

Relay 1 is controlled by user 

01~

20 

Relay 2 is controlled by user 

21 

Sign: Relay1(

30); Relay2(

31) 

EPROM 

Non-volatile memory allows remaining all setting codes in the event 
of total power failure.  

Ambient Humidity 0%~95% (Non-condensing)

 

Operating Temperature -20°C~+70°C                                          

 

 

II. Status 

Indication 

Green On 

Power on, Stand by 

Red On 

Relay 1 active 

LED 

Yellow On 

Relay 2 active 

1 Beep 

Valid key press 

2 Beeps 

Enter, exit setting mode  

3 Beeps 

Incorrect operation 

Beep 

5 Beeps 

Master Code back to 12345 (Cleared settings) 

 

III.  Operation Instruction  

 

 Jumper 

Setting 

 

4or5

RESET

Master Code reset to

default value"12345"

Reset

Normal

4 or 5 digit setting

4 digit 

5 digit 

 

 

1. Default value: “1234” for 4 digits, “12345” for 5 digits  
    It’s suggested to clear all stored codes prior to new setting.  

2. Master Code reset to default value”12345”: 

     a. Insert the jumper into 1-2 (5 beeps) 

b. Master Code reset to default value  

Copyright All Rights Reserved. 
P-MU-DG15  Ver. I  Publish:2010.08.12                                                                                                         Page: 1/ 3

 