background image

Inductive Coupling

Power Transfer

Receiver

Transmitter

Copyright © All Rights Reserved.  P-MU-WLP-100   Published: 2021.03.05

1

IR Transmitter

25

115

33.5

3

140

156

Unit: mm

Current Draw

Lock Status Output

Door Status Output

Output Power

Current Draw

Lock Status Input

Infrared Sensing

Door Opening Time

Maximum Door Gap

Maximum Tolerance

Operating Temperature

Humidity

WLP-100 Wireless Power Transfer

Installation Instruction

Input Power

Specifications

Transmitter on Frame Side

27.6 VDC or (24VAC)

1A/27.6VDC

1.3A/24VAC

Relay (Dry contacts: N.O./N.C./Com.)
Rating: 3A/ 30VDC

Receiver on Door Side

with 3/16" (4~5mm) 

Door Gap

12/24 VDC

800mA/12VDC 
400mA/24VDC

Dry contacts: N.O./Com.

Transmitter               Receiver

15 / 30 seconds
*For fail-secure locks only

3/16” (4~5mm)

Horizontal alignment : 1/16" (1mm)
Vertical alignment : 1/16" (1mm)
IR Sensing: 1/16” (1mm)

32° to +120.2°F ( 0° to +49°C )

0 to 85% Non-condensing

Unit

Unit

Reed Switch 
(Dry contacts: N.O./N.C./Com.)
Rating: 0.1A/ 20VDC

*Requires 1.5 A power when energized

Summary of Contents for WLP-100

Page 1: ...Power Transfer Installation Instruction Input Power Specifications Transmitter on Frame Side 27 6 VDC or 24VAC 1A 27 6VDC 1 3A 24VAC Relay Dry contacts N O N C Com Rating 3A 30VDC Receiver on Door Side with 3 16 4 5mm Door Gap 12 24 VDC 800mA 12VDC 400mA 24VDC Dry contacts N O Com Transmitter Receiver 15 30 seconds For fail secure locks only 3 16 4 5mm Horizontal alignment 1 16 1mm Vertical alignm...

Page 2: ...horizontal and vertical misalignment Tolerance for minor misalignment will increase as door gap decreases After checking the door and frame conditions apply the templates at the appropriate location The WLP 100 can be installed on the latch side hinge side or top of the door Washers 1a Apply the door side template 1b Apply the frame side template Make sure to align the horizontal and vertical cent...

Page 3: ... use the file if necessary 2c Check if the WLP 100 fits well in the cutout and use the file if necessary 2d Install mounting tabs using M5 screws 3 Wood Door Installation 3a Drill two 1 25mm diameter holes 1 8 3mm in depth as shown on the template 3b Drill and cut the WLP 100 main body to a minimum depth of 1 9 16 40mm and diameter of 1 25mm on the door side ...

Page 4: ...he jumper on the back of the door side unit to select the appropriate lock voltage Jumper Setting 5 Frame Installation For the frame side unit repeat steps 2 or 3 to install on a metal or wood frame Wiring Instructions Please refer to the wiring diagrams on page 5 6 WLP 100 Pigtail Wire Color Function Frame Door Leaf Input Power Reed Switch Relay Output Lock Status Lock Status Input Lock Power Out...

Page 5: ... 1 5Amp POWER SUPPLY Jumper 12VDC 12VDC 24VDC INPUT OUTPUT RED BLK YEL N C GRN COM BLU N O RED BLK GRN COM BLU N O 12V 12V max 12VDC 800mA Receiver Unit Transmitter Unit Door Status Output RED N C BLK COM WHT N O Power Input Lock Status Output Power Output Lock Status Input Fail Secure Electric Lock ...

Page 6: ... Possible Cause Unable to unlock No sensor output No door status output No lock status output Check that the power supply is connected and works properly Make sure access control relay contact is wired correctly N O Check jumper settings are correct Check door opening time is not too long the interval time is 30 seconds Check installation position alignment is correct Check door gap does not excee...