background image

User Manual 07500524    

Model 3000-524 

Page 1 

 

O

peration Manual

 

 

 

 

Model 3000-524 

4(1x12) Coax Multiplexers  

904001110

 

 

 

 

 

 

 

 

Summary of Contents for 3000-524

Page 1: ...User Manual 07500524 Model 3000 524 Page 1 Operation Manual Model 3000 524 4 1x12 Coax Multiplexers 904001110 ...

Page 2: ... Fax 925 328 4700 On the Internet www gigatronics com Warranty Giga tronics Series 3000 Switching Modules are warranted against defective materials and workmanship for three years from date of shipment or as detailed in the warranty section of this manual Giga tronics will at its option repair or replace products that are proven defective during the warranty period This warranty DOES NOT cover dam...

Page 3: ... EN61010 1 1993 Electrical Safety EN61326 1 1997 EMC Emissions and Immunity Manufacturer s Name Manufacturer s Address Giga tronics Incorporated 4650 Norris Canyon Road San Ramon California 94583 U S A Type of Equipment Model Series Number Switching Module 3000 524 Declaration of Conformity on file Contact Giga tronics at the following Giga tronics Incorporated 4650 Norris Canyon Road San Ramon Ca...

Page 4: ...ages are issued as Technical Publication Change Instructions TPCI When you are issued a TPCI do the following 1 Insert the TPCI at the front of the manual binder 2 Remove the pages from the manual binder that are noted in the TPCI 3 Replace the page s removed in the previous step with the corrected page s 4 Record the changes in the table below TPCI Number TPCI Issue Date Date Entered Comments ...

Page 5: ...anual 07500524 Model 3000 524 Page 5 Operation Manual Revision History Revision Description of Change Chg Order Approved By A Initial Release B Updated C Updated 3 10 D Updated 8 10 DT E Reformatted 3 12 RCW ...

Page 6: ...Notes 7 1 1 5 Electrical Safety Precautions 7 Chapter 2 Configuration Table 8 Chapter 3 Functional Description 9 3 1 Introduction 9 3 2 General Description 9 Chapter 4 Block Diagram 10 4 1 VXI Logical Address 11 4 2 LEDs 11 4 2 1 BUS LED 11 4 2 2 PWR LED 11 Chapter 5 Internal Settings 12 5 1 Fuse 12 5 2 VXIbus Interrupt Level Selection 12 Chapter 6 Specifications 13 Chapter 8 Register Map 14 Chapt...

Page 7: ...ous injury 1 1 3 Equipment Safety Alert CAUTION Indicates a situation which can damage or adversely affect the product or associated equipment 1 1 4 Notes Notes are denoted and used as follows NOTE Highlights or amplifies an essential operating or maintenance procedure practice condition or statement 1 1 5 Electrical Safety Precautions Any servicing instructions are for use by service trained pers...

Page 8: ...000 524 Page 8 Operation Manual Chapter 2 Configuration Table ASSY90401110 Top Assembly PL90401110 Parts List for Top Assembly ASSY85003790 PWA Assembly PL85003790 Parts List for PWA Assembly SCH85003790 Schematic of PWA Assembly ...

Page 9: ... General Description This module contains four very high frequency 1x12 coaxial relay trees The shields to the 12 inputs are switched to allow isolation of the coaxial shield from the common shield plane of the switch tree The 3000 524 is a register based VXI module The register map is carefully laid out for easy software control The interface and mechanical construction meets the specification of...

Page 10: ...User Manual 07500524 Model 3000 524 Page 10 Operation Manual Chapter 3 Block Diagram Analog Groundplane ...

Page 11: ... 1 and 255 decimal or 1 and FF hexadecimal address 0 is reserved for the resource manager However the Module fully supports Dynamic Configuration as defined in Section F of the VXI specification address 255 FF should be selected only if the Resource Manager also supports Dynamic Configuration 3 2 LEDs The following LEDs are visible at the Module s front panel to indicate the status of the module s...

Page 12: ...emoving the side cover 4 1 Fuse The ASCOR VXI 3000 524 uses a 10 Amp fuse in the 5 Volt line and is located on the Mother Board MB assembly 4 2 VXIbus Interrupt Level Selection The VXIbus interrupt level is set with three bits in the 3Eh register See the section on A16 ADDRESS SPACE REGISTER DESCRIPTION The interrupt level is factory set to no interrupt ...

Page 13: ...dwidth 100 MHz Max Power 10 watts Path resistance 1ohm Mechanical Thickness 1 200 inches Width 10 317 inches Length 13 78 inches Weight 2 lbs Connectors Four Burndy type MSD26RM 26 pin block Contacts Each block contains 13 coaxial contacts Raychem type D 602 0279 Environmental Specifications Temperature Operating 0º to 55ºC Storage 40º to 75ºC Relative Humidity Operating 0 to 90 non condensing Sto...

Page 14: ...bit data controller The Model 3000 524 can be programmed in 16 bit or 32 bit wide data Through your VXI controller write the data to the appropriate register as shown on the register map for the relay or relays in the register that is being closed When the data bit is true the relay chosen will be closed The state of the relays in a register can be determined by reading the desired register The da...

Page 15: ...x center pole 6 K11 11 J1 pin F coax shield pole 6 K12 12 13 14 15 note 1 K8 and K16 are not used in the 16x12 configuration REGISTER 8000h MODE 32 bit BITS 16 31 REGISTER 8002h MODE 16 bit FUNCTION Relays 13 24 1X12 1 BIT Description RELAY 0 16 J1 pin H coax center pole 7 K13 1 17 J1 pin H coax shield pole 7 K14 2 18 J1 pin J coax center pole 8 K15 3 19 J1 pin J coax shield pole 8 K16 4 20 J1 pin...

Page 16: ...e 5 K34 10 J2 pin F coax center pole 6 K35 11 J2 pin F coax shield pole 6 K36 12 13 14 15 REGISTER 8004h MODE 32 bit BITS 16 31 REGISTER 8006h MODE 16 bit FUNCTION Relays 37 48 1X12 2 BIT Description RELAY 0 16 J2 pin H coax center pole 7 K37 1 17 J2 pin H coax shield pole 7 K38 2 18 J2 pin J coax center pole 8 K39 3 19 J2 pin J coax shield pole 8 K40 4 20 J2 pin K coax center pole 9 K41 5 21 J2 p...

Page 17: ...e 5 K58 10 J3 pin F coax center pole 6 K59 11 J3 pin F coax shield pole 6 K60 12 13 14 15 REGISTER 8008h MODE 32 bit BITS 16 31 REGISTER 800Ah MODE 16 bit FUNCTION Relays 61 72 1X12 3 BIT Description RELAY 0 16 J3 pin H coax center pole 7 K61 1 17 J3 pin H coax shield pole 7 K62 2 18 J3 pin J coax center pole 8 K63 3 19 J3 pin J coax shield pole 8 K64 4 20 J3 pin K coax center pole 9 K65 5 21 J3 p...

Page 18: ...e 5 K82 10 J4 pin F coax center pole 6 K83 11 J4 pin F coax shield pole 6 K84 12 13 14 15 REGISTER 800Ch MODE 32 bit BITS 16 31 REGISTER 800Eh MODE 16 bit FUNCTION Relays 85 96 1X12 4 BIT Description RELAY 0 16 J4 pin H coax center pole 7 K85 1 17 J4 pin H coax shield pole 7 K86 2 18 J4 pin J coax center pole 8 K87 3 19 J4 pin J coax shield pole 8 K88 4 20 J4 pin K coax center pole 9 K89 5 21 J4 p...

Page 19: ... pin K to PCB J9 J1 pin L to PCB J10 J1 pin M to PCB J11 J1 pin N to PCB J12 J1 pin P to PCB J13 J1 pin CC to EPAD5 22 GA wire J1 pin DD to EPAD6 22 GA wire 1x12 Tree 2 J2 pin A to PCB J14 J2 pin B to PCB J15 J2 pin C to PCB J16 J2 pin D to PCB J17 J2 pin E to PCB J18 J2 pin F to PCB J19 J2 pin H to PCB J20 J2 pin J to PCB J21 J2 pin K to PCB J22 J2 pin L to PCB J23 J2 pin M to PCB J24 J2 pin N to...

Page 20: ... pin L to PCB J36 J3 pin M to PCB J37 J3 pin N to PCB J38 J3 pin P to PCB J39 J3 pin CC to EPAD9 22 GA wire J3 pinDD to EPAD10 22 GA wire 1x12 Tree 4 J4 pin A to PCB J40 J4 pin B to PCB J41 J4 pin C to PCB J42 J4 pin D to PCB J43 J4 pin E to PCB J44 J4 pin F to PCB J45 J4 pin H to PCB J46 J4 pin J to PCB J47 J4 pin K to PCB J48 J4 pin L to PCB J49 J4 pin M to PCB J50 J4 pin N to PCB J51 J4 pin P t...

Page 21: ...User Manual 07500524 Model 3000 524 Page 21 Operation Manual ...