background image

 

 

Capricorn Pro 4 Installation Note

 

 

DCP0000250(B)

 

 

This installation note is applicable for SkyEdge II-c Capricorn Pro 4 AC series: 

 

To install the SkyEdge II-c Capricorn Pro 4 CPE, the installer must:  

 

Be trained in installing the SkyEdge II-c Capricorn Pro 4 CPE 

 

Be familiar with the SkyEdge II-c CPE Installation Manual (DC-103322-X) 

 

Have the CPE configuration parameters available

 

 

The SkyEdge II-c Capricorn Pro 4 CPE is designed to be installed on a shelf in a 19-inch rack, secured to the cabinet 

by the rack mount ears.  

The CPE can be installed with either front or rear panel facing forward. By default, the CPE is supplied with rack-

mount front ears secured to the front panel. The installation kit includes an additional pair of rack-mount back ears for 

securing to the CPE rear panel to install the CPE with the rear panel facing forward. 

The CPE may contain a built-in DC Inserter.  

 

Unpacking Guidelines 

1.

 

Unpack the Capricorn Pro 4 CPE unit and its accessories. 

2.

 

Compare with the supplied BOM and verify that all the items are supplied in good condition. 

 

VSAT AC and DC power supplies are provided by Gilat. If the power to the VSAT is not through an 

AC or DC adaptor (e.g., batteries, solar panels, rectifier ETC), the power solution must be approved by 

the Gilat Technical Support. 

 

 

C

AUTION

 

 

T

HE 

CPE

  MUST  BE GROUNDED PRIOR TO INSTALLATION BY ATTACHING ONE END  OF THE GROUNDING 

CABLE TO THE GROUNDING  STUD ON THE REAR OF THE 

CPE,

  AND THE OTHER  END TO THE SITE MAIN 

GROUND CONNECTION

.

 

18AWG

 GROUNDING CABLE SHOULD BE USED

 

T

HE 

CPE

 MUST BE CONFIGURED PRIOR TO ATTACHING THE 

RF

 CABLES

 

T

HE POWER CABLE MUST BE DISCONNECTED FROM THE 

CPE

 PRIOR TO CONNECTING THE 

RF

 CABLES

.

 

 

 

 

General Precautions 

 

Do not block the ventilation openings of the CPE or place any object on top of the CPE. 

 

Do not place the CPE in a location that would deviate from typical ambient environmental conditions of 

temperature, humidity, and moisture. 

 

  

 

Warning 

B

EFORE INSTALLING THE UNIT

,

 VERIFY THAT THE ANTENNA AND 

AC

 POWER CORD ARE GROUNDED SO AS TO 

PROVIDE PROTECTION AGAINST VOLTAGE SURGES AND STATIC CHARGES

S

ECTION 

810

 OF THE 

US

 

N

ATIONAL 

E

LECTRICAL 

C

ODE

,

 

ANSI/NFPA

 

70,

 AND 

S

ECTION 

54

 OF THE 

C

ANADIAN 

E

LECTRICAL 

C

ODE PROVIDE INFORMATION WITH REGARD TO PROPER GROUNDING OF THE MAST AND 

SUPPORTING STRUCTURE

,

 GROUNDING OF THE LEAD

-

IN WIRE TO AN ANTENNA DISCHARGE UNIT

,

 SIZE OF 

GROUNDING CONDUCTORS

,

 LOCATION OF ANTENNA DISCHARGE UNIT

,

 CONNECTION TO GROUNDING 

ELECTRODES AND REQUIREMENTS FOR THE GROUNDING ELECTRODE

.

 

 

Connecting Grounding Cable 

Connect the grounding cable (GND) from the CPE to the approved site.  

 

Connecting Power 

 

  

 

Warning 

T

HE UNIT MAY HAVE MORE THAN ONE POWER CORD

.

 

T

O REDUCE THE RISK OF ELECTRIC SHOCK

,

 DISCONNECT 

ALL POWER CORDS BEFORE SERVICING THE UNIT

.

 

 

 

Reviews: