Page 1: ...Gingerway Technologies Co Ltd SmartC Wi Fi Smart Gateway SmartC Wi Fi Smart Gateway with GSM GW 9323 GW 9324 Instruction Manual Enjoy the Life 201804 V1 4 ...

Page 2: ...ain controller IR transmitter power strip alarm sensor etc Keywords Terminal Node The each gang light socket curtain alarm sensor and other devices which can be controlled by the smart gateway Binding Establish a secure connection between gateway and the terminal nodes Device Control Control the on off state and arm disarm state of single terminal node Scene The on off state and arm disarm state c...

Page 3: ...nsors linkage trigger controlling Support data backup and restore Low battery notification of alarm sensors Field voice monitoring GW 9324 Local GSM call SMS APP push alarm notification COM 12V PUSH SPK IN1 ON OFF RESET GSM 12V1A DC Front side Back side 1 2 3 4 5 6 7 8 9 0 Arm Scene Arm Indicator Scene3 At home Microphone RESET key COM is common port negative terminal IN1 is 1 gang alarm sensor in...

Page 4: ...gs Slide the power switch to OFF position then slide it to ON position When the screen is on long press RESET key for 10 seconds the gateway will be restored to factory settings all data will be deleted except backup data The keys on the left and right columns of gateway panel are 1st to 8th scene of gateway Press Arm Scene key gateway will execute Arm scene all the alarm sensors which in this gat...

Page 5: ...nto Gateway Setting interface to set the gateway Gateway Settings Gateway General 1 On General interface you can change gateway name check and upgrade new version 2 Please set the cloud server address as cloudhk gingerway com and please set it as cloud gingerway com if in mainland China The cloud server which you used in the login interface must be same as you set for the gateway 3 For the reason ...

Page 6: ...e detection signals have no effect on trigger Set as ON indicates the trigger condition is that human body infrared or external trigger signals being detected Set as OFF indicates the trigger condition is human body infrared or external trigger signals not being detected You can also set the valid time and date for trigger according to your requirement 7 Tools Set Control Panel Icon User can use t...

Page 7: ...o response of operation on gateway panel The power switch hasn t been turned on Open the the back cover of gateway and slide the power switch to ON position Gateway can t control devices The devices haven t been bound with gateway Bind the devices with gateway refer to the instructions Local GSM alarm notification can t be received The local GSM alarm call has been set Set your phone number into l...

Page 8: ... Address 3 Floor Building A6 Xingye Industrial Park Zhongshanyuan No 2 Road Nanshan District Shenzhen Guangdong China Tel 0755 28779595 Fax 0755 28779405 Website www gingerway com Gingerway products are guaranteed for 2 years since the date of purchase During the warranty period if Gingerway products malfunction not contain artificial damages under normal circumstances they can be free repaired or...