background image

System 3000

speed regulator insert

speed regulator insert
Order no.: 2460 00

Operating instructions

1

Safety instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Danger of electric shock. Always disconnect before carrying out work on the device or load.

Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the device is switched off.

These instructions are an integral part of the product, and must remain with the end customer.

2

Intended use

Speed controller for controlling the speed of single-phase motors e.g. induction or shaded
pole motors

Mounting in appliance box according to DIN 49073

Operation with suitable cover

3

Product characteristics

Product characteristics

Device is operating in leading edge phase control

Operation without neutral conductor possible

Switch-on via soft start to maximum speed

Minimum speed can be saved permanently

Connection of extensions possible

Electronic short-circuit protection with permanent switch-off after approx. 100 ms

Electronic over-temperature protection

4

Operation

Switching motor or adjusting speed

The operation on the main device and the 3-wire rotary extension is identical.

Press the control button briefly: Motor switches on or off.

Turn the control button to the right: Speed is increased.

Turn the control button to the left: Speed is reduced.

Basic operation using 2-wire extension with push-button top or push-button

Press briefly: Motor switches on or off.

Press and hold: The speed is changed as long as the button is pressed, at maximum up
to the respective end value.

Push-button: The adjustment direction is changed with each new long actuation.

1 / 5

82404702

01.04.2021

Summary of Contents for System 3000 2460 00

Page 1: ...tion with suitable cover 3 Product characteristics Product characteristics Device is operating in leading edge phase control Operation without neutral conductor possible Switch on via soft start to maximum speed Minimum speed can be saved permanently Connection of extensions possible Electronic short circuit protection with permanent switch off after approx 100 ms Electronic over temperature prote...

Page 2: ...N 1 1 N L 4 2 1 5 6 3 Figure 1 Connection diagram with optional extensions 1 Button Test 2 LED display 3 Rotary axle 4 3 wire rotary extension 5 2 wire extension 6 Push button NO contact The connection of a central extension is not possible Operation without neutral conductor possible Only connect illuminated push buttons if they have a separate N terminal Precondition The maximum motor current Im...

Page 3: ...insulated tools for the work Cover up live parts in the working environ ment The minimum speed must be set so that the motor does not stop at the lowest speed set ting Prerequisites Speed controller is ready for operation and the central plate is not mounted Press the button Test 1 until LED 2 lights up The current operating state remains the same After 45 seconds without an actuation the LED 2 go...

Page 4: ... 1 overheating protection has tripped Reduce the connected load Disconnect the speed controller from the mains by switching off the circuit breaker Let the speed controller cool down for at least 15 minutes Switch on the circuit breaker and speed controller again Cause 2 short circuit protection has tripped Disconnect the speed controller from the mains by switching off the circuit breaker Elimina...

Page 5: ...rsiepen GmbH Co KG Elektro Installations Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de 5 5 82404702 01 04 2021 ...

Reviews: