background image

V.

3

.3

04/11/2020

EN 

USER MANUAL

STI

| marca propiedad de | est une marque de | trade mark propiety of | ist als Marke des Markeneigentums zu kennzeichnen
|marchio proprietà di

Pol. Empordà Internacional C

/ Molló 3

 17469 VILAMALLA  - (Girona) SPAIN

T. (34) 972 527 212 - F. (34) 972 527 211

El fabricante se reserva el derecho de modificar sin previo aviso las características de sus productos para introducir mejoras técnicas o cumplir con nuevas regulaciones oficiales./Le 

constructeur se réserve le droit de modifier les caractéristiques de ses produits en vue d’y apporter des améliorations techniques ou de respecter de nouvelles réglamentations./The 

manufacturer reserves the right to modify the specifications of its products in order to make technical improvements or comply with new regulations/ Der Hersteller behält sich das Recht vor, 

ohne Vorankündigung die Eigenschaften seiner Produkte zu ändern, um weitere Verbesserungen zu erzielen oder neuen offiziellen Richtlinien nachzukommen/ Il fabbricante si riserva il diritto 

di modificare senza alcun preavviso le caratteristiche dei suoi prodotti in vista di apportare migliorie tecniche o di rispettare nuove regolamentazioni.

Summary of Contents for Baxtran STI

Page 1: ...oit de modifier les caractéristiques de ses produits en vue d y apporter des améliorations techniques ou de respecter de nouvelles réglamentations The manufacturer reserves the right to modify the specifications of its products in order to make technical improvements or comply with new regulations Der Hersteller behält sich das Recht vor ohne Vorankündigung die Eigenschaften seiner Produkte zu änd...

Page 2: ...N 13 6 KEY BOARD DISPLAY 14 7 OPERATION 16 7 1 POWER ON OFF 16 7 2 ZERO 16 7 3 TARE 17 7 4 SAMPLE WEIGHING 17 7 5 SELECT UNIT 17 7 6 PLU SETTINGS 18 7 6 1 USING DIRECT PLU 18 7 6 2 USING INDIRECT PLU 20 7 7 BACK LIGHT 22 7 8 AUTOMATIC UNIT PRICE CLEAR 22 7 9 ACUMULATION 22 7 10 GIVE CHANGES 23 7 11 SALES REPORT 24 7 12 PAPER ROLL INSTALLATION 25 8 PARAMETERS 26 8 1 PARAMETER SETTINGS 27 8 2 PARAME...

Page 3: ...3 EN USER MANUAL STI ...

Page 4: ...STRUCTION OF THE EQUIPMENT The price computing scale is a precision electronic instrument handle it carefully Do not install the scale in direct sunlight Verify the local voltage and receptacle type are correct for the scale Only use original adaptor other could cause damage to the scale Pluggable equipment must be installed near an easily accessible socket outlet Avoid unstable power sources Do n...

Page 5: ...5 EN USER MANUAL STI 2 ASSEMBLY WITH WITHOUT COLUMN 2 1 ASSEMBLY WITH COLUMN 1 Insert the cable into the column 2 Fit the column inside the support ...

Page 6: ...NUAL STI 6 3 Flip the scale and place the four screws in the holes and screw them so that the column is secure 2 2 ASSEMBLY WITHOUT COLUMN 1 Unscrew the front and rear screws that hold the screen with the column ...

Page 7: ...7 EN USER MANUAL STI 2 Separate the column manually in two pieces 1 2 ...

Page 8: ...EN USER MANUAL STI 8 3 Flip the scale remove the sheet and insert the excess cable into the hole 4 Fit the customer s screen inside the support ...

Page 9: ...h stable It uses 18mm 9 5mm LCD display with white LED back light Accumulation weighing unit conversion and change function 33 membrane keyboard 8 direct PLUs and 100 indirect PLUs supported alphanumeric PLU information 4 direct keys for vendors Auto unit price clear operation With back office software to manage product information and sale report AC Adaptor Rechargeable battery Built in 58mm ther...

Page 10: ... RS232 RJ11 as standard port Operation Temperature 10 C 40 C Stability Time 1 Seconds typical Power AC Adaptor 12V 2500mA standard rechargeable Battery 6V 4Ah Keypad 33 membrane keys ADC Sigma delta Internal counts 600 000 Gross Weight 7kg 4 2 PRINTER SPECIFICATIONS Printing Method Thermal dot line printing Number of dots line 384 Dots density 8 Printing width mm 48 centered on paper Paper width m...

Page 11: ...11 EN USER MANUAL STI 4 3 OVERALL VIEW Client display Pole SST Pan Level bubble Printer Keyboard Display Calibration switch Adjustable foot Adaptor jack ...

Page 12: ...EN USER MANUAL STI 12 4 4 CONNECTORS No Interface Description Spec 1 RS 232 For computer ECR or TPuP printer Standard 2 RJ11 Support Cash drawer 6V Standard 3 5 DIMENSIONS 1 2 ...

Page 13: ... the adaptor pin to jack Adaptor simply plug into the mains power The scale no needs to be turned on The battery should be charged for 4 hours for full capacity The symbol status of the battery Battery voltage has dropped Fully charged Do not use any other type of power adaptor than the one supplied with the scale Verify that the AC power socket outlet is properly protected INSTALLATION Place the ...

Page 14: ... CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P4 P8 to B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P4 P8 Numeric Keys enter unit price PLU and enter alphabetic characters in the corresponding menus B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 ...

Page 15: ...g kg V1 V2 V4 V3 SAVE T Decimal point On PLU edition pressing twice space function PANTONE 7541 B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 STI 100 g kg V1 V2 V4 V3 SAVE T 1 V2 P1 P2 P3 P4 3 V4 P5 P6 P7 P8 to PANTONE 7541 B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 10...

Page 16: ...L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P1 P2 P3 P4 P5 P6 P7 P8 key The display is switched on and the self test is started If you want to switch off press the key again 7 2 ZERO Environmental conditions can lead to the balance exactly zero in spite of the pan not taking any strain However you can set t...

Page 17: ...RDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T key Zero is displayed tare weight is cleared 7 4 SAMPLE WEIGHING Place goods to be weighed on the platform Wait few seconds for stability display Read the result Avoid overloading When display appears ol reduce the load or unload 7 5 SELECT UNIT Press B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ T...

Page 18: ...EAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 STI 100 g kg V1 V2 V4 V3 SAVE T V1 V2 P1 P2 P3 P4 V3 V4 P5 P6 P7 P8 key to shift location For Ex Press keys are for apple Weight SET APPLE Unit price PNAME Total price Select product weight mode Press B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P4 P8 key...

Page 19: ...T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 STI 100 g kg V1 V2 V4 V3 SAVE T V1 V2 P1 P2 P3 P4 V3 V4 P5 P6 P7 P8 key to confirm Set tax Display will be show SET ELECT VAT 1 Press 1 2 or 3 numeric keys for select TAX A B or C RE CAL PLU INFORMATION When you want to weigh stored PLU content Press PANTONE 7541 B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC P...

Page 20: ...be blink press numeric keys to input product name press NTONE 7541 B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T 1 P2 P3 P4 5 P6 P7 P8 or PANTONE 7541 B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P1 P2 P3 P4 P5 P6 P...

Page 21: ...TI 100 g kg V1 V2 V4 V3 SAVE T V1 V2 P1 P2 P3 P4 V3 V4 P5 P6 P7 P8 key to confirm Set pre tare Display will be show Weight SET PRE TARE Unit price 0 000 Total price Press numeric keys to input PRE TARE value and press PANTONE 7541 B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 STI 100 g kg V1 V2 V4 V3 SAVE T V1 V2 P1 P2 P3 P4 V3 V4 P5 ...

Page 22: ...ODE AUTO Backlight will be turned on when start to use or when weight is more than 20d when weight is less than 20d the backlight will be off after a second SET BT MODE ON Backlight stays on permanently SET BT MODE OFF Backlight function will be turned off 7 8 AUTOMATIC UNIT PRICE CLEAR LPP can set automatic unit price clear Press B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECOR...

Page 23: ...lly 7 10 GIVE CHANGE Press B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P2 P3 P4 P6 P7 P8 Key and select the desired vendor Displays will be show summation price Weight 2 63 Unit price PAY Total price 0 00 By pressing numeric keys enter the amount which is given customer Weight 2 63 Unit price PAY Total pr...

Page 24: ... price Total Total price By pressing PANTONE 7541 B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P1 P2 P3 P4 P5 P6 P7 P8 or PANTONE 7541 B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P1 P2 P3 P4 P5 P6 P7 P8 keys Total...

Page 25: ... Press the button to open the printer cover 2 Open the printer cover 3 Load paper rolls 4 Pull the paper outside of the printer cover and press both side to close correctly cover 5 Pull the paper towards the tear bar from one side to the other 1 2 3 4 5 ...

Page 26: ...AL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P2 P3 P4 P6 P7 P8 or B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T P2 P3 P4 P6 P7 P8 It can choose menu block one by one RETURN TO WEIGHING MODE Press B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC P...

Page 27: ...eive PLU and report information from the back office software via RS232 Continuous data transmission OFF RS232 function disable bAUD 1200 2400 4800 9600 19200 38400 115200 Set baud rate COM 2 CHANEL RJ45 Com function selection OFF WIFI Pt YPE PSEND Download PLU information to the scale or receive PLU and report information from the back office software via RJ45 WIFI OFF Com function disable BAUD 1...

Page 28: ...N Set Zero tracking function OFF F7 PDECI 0 Set the price decimal 0 0 0 00 0 000 F8 PAY ON Set pay function OFF F9 Minim 2D Set minim weight function 20d F10 GRA Set the local gravity F11 TAX BRANCH NAME Enter the names of department scale and tax SCALE NAME TAX NAME TAX TYPE A B or C TAX WAY Include exclude or no tax TAX USER Default or ask F12 T CURR EUR For currency selection CUSTOM USD F13 LAN...

Page 29: ...gs and will to show CAL F0 Press Cal switch Press B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RECORDS WXYZ TUV MNO GHI CE 3 6 9 7 8 4 1 0 2 5 100 g kg V1 V2 V4 V3 SAVE T key to confirm for calibration display will be show UNLOAD Remove the goods from the platform and make sure STABLE indication has been enable Press B L COPY MEM PLU U SAVE T M TOTAL MR JKL DEF ABC PQRS _ CLEAR RE...

Page 30: ...mmunication S T G S k g CR LF HEADER 1 HEADER 2 WEIGHT DATA WEIGHT UNIT TERMINATOR Unstable data communication U S G S k g CR LF HEADER 1 HEADER 2 WEIGHT DATA WEIGHT UNIT TERMINATOR Gross data communication S T G S k g CR LF HEADER 1 HEADER 2 WEIGHT DATA WEIGHT UNIT TERMINATOR Tare Net Weight data communication S T N T k g CR LF HEADER 1 HEADER 2 WEIGHT DATA WEIGHT UNIT TERMINATOR Unsable Tare Net...

Page 31: ...LY TERMINTOR 2 start170718 r n end170718 r n export custom report s t a r t 1 7 0 7 1 8 r n Start Start date TERMINATOR e n d 1 7 0 7 1 8 r n End End date TERMINATOR 3 product 1 12 direct PLU r p r o d u c t 0 1 r n product PLU number TERMINATOR 00 N 13 4 list r n Export product information p r o d u c t 0 1 r n product PLU number TERMINATOR N 99 5 list r n Export product information l i s t r n L...

Page 32: ...EN USER MANUAL STI 32 11 PRINT FORMAT ...

Page 33: ... Check wireless settings or change Com settings from the wireless settings from the wireless Err 11 Communication protocol error Check communication settings Err 12 Accumulation error Max accumulation times 99 999 weight 999999 Err 13 Lack of unit weight Check unit weight entry data must be 0 5d Err 14 Lack of sample Check counting samples entry must be 20d Err 15 Gravity error Check the gravity s...

Page 34: ...EN USER MANUAL STI 34 13 DRAWING ...

Page 35: ...r button 1 17 Spring 2 18 Paper baffel 1 19 TP230 printer control board 1 20 Paper axis 1 21 Roll paper 1 22 Load cell bracket rubber 4 23 Internal hexagon screw 4 M6x20 24 Spring washer 4 M6 25 Washer 4 M6 26 Load cell bracket 1 27 Load cell 1 28 Hexagon screw 4 M4x16 29 Hexagon nut 4 M4 30 round self thread screw 4 ST4x20 31 Load cell bracket 1 32 6V10Ah lead acid battery 1 33 round self thread ...

Page 36: ...ing bolt 1 53 Pole display rear cover 1 54 Main board 1 55 Foam 1 56 Pole display overlay 1 57 Pole display front cover 1 58 round self thread screw 2 ST4x10 59 round self thread screw 1 ST3x16 60 round self thread screw 16 ST3x8 14 DOWNLOAD SOFTWARE 1 TTC software for PC for the management of the PLU s and to generate reports Free download through the website https www baxtran com en retail scale...

Page 37: ...37 EN USER MANUAL STI ...

Page 38: ...EN USER MANUAL STI 38 ...

Page 39: ...39 EN USER MANUAL STI ...

Page 40: ...EN USER MANUAL STI 40 marca propiedad de est une marque de trade mark propiety of marchio proprietà di Pol Empordà Internacional C Molló 3 17469 VILAMALLA Girona SPAGNA T 34 972 527 212 F 34 972 527 211 ...

Reviews: